Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹8.7 Laccepted-aoc | ₹8.7 L | accepted-aoc |
Tender Value
₹8.4 L
EMD Value
₹8,351
Closing Date
31 Jan 2026, 5:00 pmClosed
O/o Executive Engineer GRP Division No 2 Ongole
O/o Executive Engineer GRP Division No 2 Ongole
Renovation of electrical items of model room at Gundlakamma Dam site of Gundlakamma Reservoir Project Chinna Mallavaram village Maddipadu Mandal, Praksam district.
887266
14/2025-26 Dt:09.01.2026
OPEN - NCB
Civil Engineering Works
PRAKASAM, ANDHRA PRADESH
9 documents required · 8 mandatory · 1 optional
₹296
₹8,351
15 Feb 2026
12 Jan 2026
12 Jan 2026
Providing and fixing factory made UPVC White Colour Sliding Glazed window above 1.50 m in height dimension comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from rollforming process of required length (shape & size according to UPVCprofile), appropriate dimension of UPVC extruded glazing beads, UPVC extruded interlocks and UPVC extruded Inline sash adaptor (ifrequired), EPDM gasket, wool pile, zinc alloy (White powder coated) handle on one side of extreme panel along with zinc plated mild steel multi pointlocking having transmission gear with keeps, zinc alloy (white powdercoated) touch lock with hook (if required for wire mesh panel), stainlesssteel (SS 304 grade) body with adjustable double nylon rollers (weightbearing capacity to be 120kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitredcut and fusion welded at all corners,including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shallbe filled with weather proof silicon sealent over backer rod of requiredsize and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge inclusive of cost of Single / double glass panes, wire mesh and silicon sealent .Two track two panels sliding window made of (big series) frame 67 x 50 mm& sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of window above2.50 sqm upto4.00 sqm.) (BMT-P.81)
Supply and run of 2 of 56/0.30 mm ( 4 Sq.mm) FR PVC insulated flexible copper cable in existing pipe for mains including all labour charges etc., complete.
Supply and run of 1 of 36/0.3mm (2.50 Sq.mm) FR PVC insulated flexible copper cable in existing pipe for earth continuity including all labour charges etc., complete.
Supply and run of 1 of 14/0.30 mm ( 1.00 Sq.mm) FR PVC insulated flexible copper cable in existing pipe for mains including all labour charges etc., complete.
Supply and Fixing of 20mm dia 1.5mm thick P.V.C. pipe (ISI MARK) concealed in wall with all required accessories including masonary work for light, fan and separate plug point with well seasoned wooden deep box including all labour charges etc., complete.
Supply and fixing of 8 or 9 (MAT 02714, e) Hot Dip galvanized 18 SWG Module metal box with earthing terminal
Supply of …………. Makes: As per list of recommended brands as category I (ELEC 1.8.3) 12 Modular Vertical Cover Frame. (MAT 02872, f).
Supply of …………. ISI marked Makes: As per list of recommended brands as category I.2 Module Modular type electronic step type Fan Regulator (MAT 02846, n).
Supply and fixing of 6A 3 pin wall Plug socket with 6A switch control on a common switch board with earth continuity including wire leads, earth connections along with all labour charges etc.,complete.
Supply and fixing of 16A 3 pin/ 6A 3pin Plug Socket with Indicator lamp and 16Amps fuse unit and 16 Amps switch control ( 5 in one) on decolam sheet covered board including earth connection and all labour charges etc., complete on wall
Supply and fixing of batten holder/ Slanting holder in lieu of ceiling rose of light point complete with all connections and all labour charges with 40W bulb ( for new installation)
Supply and Transportation of 1.5 Ton Split type Air-Conditioner, fitted with Hermetically sealed compressor, operating on refrigirant R-22 / Non- CFC High wall mounting cofirming to IS : 1391, suitable for operation on 230V, 50 HZ, Single phase, A.C Supply capable of Performing Cooling, Dehumidifying, Air Circulating, Filtering with cooling and condensing units, with 5 Mtrs of required size of Copper piping duly insulated and 3 core copper flexible chord of required length etc., complete.
Supply & fixing of 1200mm (48") Sweep 230V, A.C 50 HZ Ceiling fan with 3 Blades and double ball bearings with all standard Accessories.
Supply and erecting resistance type regulator for Ceiling fans 900/1200/1400 mm sweep complete erected on existing board.
Supply & fixing of fresh air exhaust fan of light duty 250V A.C 50HZ 225 mm (9")/300mm size (12") 1350 R.P.M Metallic body plastic blades, wire mesh etc., complete.
Providing independent earthing by excavating a trench to a depth of 2.10 M in all soils, as per size specified in the data, using 40mm dia 'B' class GI pipe of 2.50Mtrs length with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and Charcoal in layers and all labour charges etc., complete for small Quarters.
Supply and fixing of 20W, 2400 lumens, T8 not less than 1100 mm length LED retrofit tube light with aluminum anodized body, input voltage AC 220 - 260 Volts, having luminous efficacy >=100 lumens/ watt, with PF>0.9, surge protection: 2KV, THD70, etc., as per IS 10322 (Part 5/ Sec 1), 2012, complete with earth connection and not less than two years warranty. Makes: As per list of recommended brands as category I.
Supply and transportation of 60W LED Flood light Luminaire made of pressure diecast alluminium housing with powder coated,having protective toughned glass, Supply Input voltage 120 - 270 V AC, P.F > 0.90, high power LED's System efficacy >100lm/W and junction temprature < 70°C, with Ingrees protection IP66, Luminaire performance complies to IS 10322 (Part 5 / Sec-3), IK05, Driver surge protection 4KV, In house additional Surge protection ≥ 10KV with wide/ Narrow beam optics, THD<10% at 110 Volts AC, driver efficiency >90%, , CCT: 3000K -5700K, minimum CRI>70, etc., complete. Makes : As per list of recommended brands as category I
Supply and Transportation of ……. Single phase Mono block CI body motor pumpset confirms to IS 9079:2002Makes: As per list of recommended brands as category I. ELEC-5.4.11, MAT-03700
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BOQ carpet 2025-26.xlsx
TENDER_DOCUMENT • 0.59 MB
Inviting bid - Main page 250KV.doc
TENDER_DOCUMENT • 0.19 MB
TENDER SCHEDULE CONDITIONS-32 pages.doc
TENDER_DOCUMENT • 0.16 MB
~$viting bid - Main page garden 2023-24.doc
TENDER_DOCUMENT • 0.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .