Microprocessor based Main Fire Alarm Control panel, Photo Electric type smoke detector, Heat Fixed Temperature Detector, Double action Manual pull station, Horn cum strobe, Signal module, Isolator module, Auto dialler, Repeater panel, 2core 1.5 sqmm ... FRLS copper cable , ... Armoured Copper Cable , ...
Supplying of the 4Core X 50Sqmm one length Copper Armored PVC insulated PVC sheathed XLPE power cable From Transformer to Power house, Supplying of the 200A 3 Pole 25 KA Molded Case Circuit Breakers MCCB, Laying and fixing PVC insulated and PVC ... XLPE power cable of ... number PVC insulated and ... armoured XLPE cable up ... copper armoured cable using ...
LT 1.1 KV XLPE 3.5 Core cables of size 70 sq mm ,120 sqmm and 300 sqmm and LT 1.1 KV Single core 630 Sq mm XLPE core and 3 Core X 70 + 1 x 16 + 50 Sq.mm LT AB Cable
AS PER BOQ AND TENDER DOCUMENT
AS PER TENDER DOCUMENTS AND BOQ
AS PER BOQ AND TENDER DOCUMENT
AS PER TENDER DOCUMENTS AND BOQ
Supply of 12 pair 1.5 Sq mm cable, Supply of power cable - 3C X 2.5 SQ MM, Supply of signal cable - 1 P x 1.5 sq MM
Supply, Erection, Testing and Commissioning of i) 132 kV DC line (0.5 Km) by making LILO of existing 132KV Kandukur-Kavali SC line between Loc.No:264-266 to 132/33KV SS Ulavapadu ii) Replacement of ACSR Lynx Conductor with ACSS Lynx Conductor on Existing 132KV Kandukur-Kavali SC line (33 KM) from 132 KV SS Ulavapadu (between Loc 264-265, LILO Point) to 132 KV SS Kavali iii) Stringing of 2nd Circuit (6.5 KM) on Existing 132 KV Kandukur -Ulavpadu DC/SC Line and iv) 3 Nos 132KV bays along with bus extension at 132/33 KV SS Ulavapadu in SPSR Nellore district on turnkey basis
Providing HVAC System to the Staff Halls/work stations to all the Department offices in all 4 floors (G+1+2+3) of Integrated Collectorate Complex Building at Srikakulam (Indoor & Outdoor Power cables, Panel boards, Transformers & APEPDCL Charges).
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) -- Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6642251 Dated : 03-09-2025 Bid Document 1/5 Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) -- Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6641817 Dated : 03-09-2025 Bid Document 1/5 Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) -- Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6501659 Dated : 28-07-2025 Bid Document 1/5 Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Refurbishment Renovation of overhead roofing by using high grade soft light weight panels with 2mm grid channel for support, Refurbishment of wall sliding by using by high grade water proof texture emulsion of approved colour, Concealed electrical ... Sqmm PVC insulated copper ... copper conductor single ...
Supply, erection, testing and commissioning of Stringing of second circuit on 132KV Yemmiganur-Madhavaram DC/SC line with ACSR Panther conductor (26.8km) and 01No. new 132KV Bay extension at 132KV SS Madhavaram and 01No. new 132KV bay extension at 132KV SS Yemmiganur in Kurnool district
Supply erection testing and commissioning of stringing of second circuit on 132KV Yemmiganur-Madhvaram DC/SC line with ACSR panther conductor (26.8km) and 01No. new 132KV Bay extension at 132KV SS Madhavaram and 01No. new 132KV Bay extension at 132KV Yemmiganur in Kurnool district
Transformer oil filtration , replacement of transformer oil of 400KVA, 6.6KV/433V Power Transformer at S/R-III,overhaul of power transformers at locations of S/R's-I&II&replacement of failed 433V/415V 3-phase 4-wire power/ lighting ... of power cable in ...
Transformer oil filtration , replacement of transformer oil of 400KVA, 6.6KV/433V Power Transformer at S/R-III,overhaul of power transformers at locations of S/R's-I&II&replacement of failed 433V/415V 3-phase 4-wire power/ lighting ... of power cable in ...
Transformer oil filtration replacement of transformer oil of 400KVA 6.6KV 433V Power Transformer at SR-III,overhaul of power transformers at locations of SR s I and II and replacement of failed 433V 415V 3 phase 4 wire power lighting distribution or ... of power cable in ...
Transformer oil filtration , replacement of transformer oil of 400KVA, 6.6KV/433V Power Transformer at Stacker Reclamier-I,II,III,IV overhaul of power transformers at locations of S/R's-I&II& replacement of failed 433V/415V 3-phase 4-wire power/ ... of power cable in ...
Transformer oil filtration replacement of transformer oil of 400KVA 6.6KV 433V Power Transformer at SR-III,overhaul of power transformers at locations of SR s I and II and replacement of failed 433V 415V 3 phase 4 wire power lighting distribution or ... of power cable in ...
4 CORE CABLE, CONDUCTOR MULIT STRAND ATC SIZE 24 BY 0.2MM (Q3)
Construction of Semi-Permanent shelters including Internal Water Supply, Sanitary Installations, CC pavement, Chain link fencing internal electrical installations, 250 KVA sub-station, UPS, LAN Networking system, EPABX, Split Acs, STP, lightening ... lightening conductor , ...
APGENCO-SRB-SRBPH-Supply of Material and labour charges for erection of new 11KV over head line with 55Sq.mm AAA Conductor over 9.1Mtrs PSSC Poles,40Mtrs span in urban area from four pole structure in APGENCO colony to Administrative building and APGENCO Guest House,Srisailam Project.
ERECTION OF NEW 33KV LINES UNDER 33KV DARSI FEEDER, 33KV MUNDLAMURU FEEDER AND 33KV TALLURU FEEDER WHICH ARE OVERLOADED/AGED FEEDERS OVER PROPOSED M+6/M+9 TOWERS WITH 157 SQ.MM AL 59 CONDUCTOR IN OPERATION CIRCLE ONGOLE IN THE JURISDICTION OF APCPDCL ON TURNKEY BASIS
LED Batten (Q2), Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3), XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2), MCB - Miniature Circuit - Breakers for A.C. Operation as per IS/IEC 60898 (Part 1) ... (Q3), PVC Insulated Copper Cable Single ... Flexible Conductor (V2) ... Wood, Copper Cable , ...
3.5 core 50 square mm, 1.1 kv grade flat armoured, 50 square mm, 50 square mm 3.5, XLPE INSULATED 1.1 KV
3C X 150 Sqmm, 1.1 KV grade annealed tinned copper conductor EPR insulated
Electrical Service wire, 3 core 4 sqmm copper wire, 7 20 single core wire, 2 Point 5 sqmm Copper Wire, 63 A Fuse cut outs, Electrical meter box waterproof, motor winding charges, Submersible motor pipe jointing kit, Motor panel board, Capacitor, 32 AMP MCB, Tape Rolls, Plastic Tags, Gl Clamps, Motor lifting and Install, Electrician Charges, 1inch Garden Hose Pipe, 32 MM UPVC pipe, 20 MM UPVC pipe, CPVC Ball Valve, UPVCT Bends L Bends, Providing 1000 Ltrs Syntax water tank over Iron stand including cost of necessary plumbing fixture and labour charges etc complete including Taxes
Providing Power infrastructure by laying 33kV single circuit one side and 11kV single circuit other side (as Double circuit) on 12.5M spun poles with span of 40 M with 100 sq.mm AAAC DOG conductor at 2nd de-notified area for a length of 7.6KM at Western Sector, Atchutapuram, Visakhapatnam
Supply, Erection, Testing and Commissioning of i) 132 kV DC line (0.5 Km) by making LILO of existing 132KV Kandukur-Kavali SC line between Loc.No:264-266 to 132/33KV SS Ulavapadu ii) Replacement of ACSR Lynx Conductor with ACSS Lynx Conductor on Existing 132KV Kandukur-Kavali SC line (33 KM) from 132 KV SS Ulavapadu (between Loc 264-265, LILO Point) to 132 KV SS Kavali iii) Stringing of 2nd Circuit (6.5 KM) on Existing 132 KV Kandukur -Ulavpadu DC/SC Line and iv) 3 Nos 132KV bays along with bus extension at 132/33 KV SS Ulavapadu in SPSR Nellore district on turnkey basis
Transformer oil filtration , replacement of transformer oil of 400KVA, 6.6KV/433V Power Transformer at Stacker Reclamier-I,II,III,IV, Overhaul of 3-Phase, 11KV/415V, 2000KVA Power transformer , overhaul of power transformers at locations of ... of power cable in ...
Consultancy services for appointment of Authority Engineer for Design Review & Construction Supervision Quality Assurance and technical auditing if Surbey Investigation Design Construction Testing commissioning of smart infrastructure works of ... for power cables , ...
Providing Power infrastructure by laying 33kV single circuit one side and 11kV single circuit other side (as Double circuit) on 12.5M spun poles with span of 40 M with 100 sq.mm AAAC DOG conductor at 2nd de-notified area for a length of 7.6KM at Western Sector, Atchutapuram, Visakhapatnam (2nd Call)
Providing Power infrastructure by laying 33kV single circuit one side and 11kV single circuit other side (as Double circuit) on 12.5M spun poles with span of 40 M with 100 sq.mm AAAC DOG conductor at 2nd de-notified area for a length of 7.6KM at Western Sector, Atchutapuram, Visakhapatnam (2nd Call)
Providing Power infrastructure by laying 33kV single circuit one side and 11kV single circuit other side (as Double circuit) on 12.5M spun poles with span of 40 M with 100 sq.mm AAAC DOG conductor at 2nd de-notified area for a length of 7.6KM at Western Sector, Atchutapuram, Visakhapatnam (2nd Call)
Supply of 4 TR vertical split type air conditioner of floor mounting, Supply of 2 TR Split DC Inverter Cool Type air conditioner, Supply of 1 point 5 TR Split DC Inverter Cool Type air conditioner, Installation, testing and commissioning of 4 TR ... Aluminium conductor armoured ... armoured power cable , ... Copper conductor flexible ... flexible power cable , ... Copper conductor flexible ... flexible power cable , ... number PVC insulated and ... XLPE power cable , ...
PVC Flat Cable, Copper Conductor with PVC Insulation and Sheath as per IS 694 (Q3)
PVC Flat Cable, Copper Conductor with PVC Insulation and Sheath as per IS 694 (Q3)
Supply and Installation of Heavy Duty Horizontal Double Mounted 5KM Range Siren, Underground Cabling of Signal Cable with Ducting, Marking as per SoW, Overhauling and Integration of Existing Siren in New System, 3 Phase UG Armoured Cable from MES distribution point to Roof top, Grouting Foundation Cementing and Weather Proof Cabinet and Misc Works
6 KVA UPS in Parallel configuration, Batteries, Battery Rack, MCB Enclosure box, 64 Amp MCB, 32 Amp MCB, Power cable, Laptop, RCMS Software, LAN Cable, Perforated PVC duct, Power Strip, Installation and Commissioning, Training
telecommunication cable Telecommunication Cable ( 200 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Govering Specification for telephone pair cable TEC Specification G/WIR06/02 - Conductor diameter Nominal ... - Conductor Materail ...
Rectification of conductor damages in 132KV Nellore-Atmakur feeder between loc.40-41 (top phase), 220KV Nellore-Manubolu-I feeder between Loc.46-48 (top phase and middle phase) and 220Kv Nellore-Manubolu-II feeder between Loc.No.46-48 (top and middle phases) in EHT lines sub-division, Nellore in SPSR Nellore District
Supply of 1. U-bolts 16mm 2. 5- bolted twin zebra/ Moose tension hardware 400mm spacing 3.Spacer clamps with 400mm spacing for twin moose 4. Post type insulator supporting clamps for twin conductor for 220kv for the work of strengthening of bus-I and bus-II sections of 220kv VSS-I
Rectification of conductor damages in 132KV Nellore-Atmakur feeder between loc.40-41 (top phase), 220KV Nellore-Manubolu-I feeder between Loc.46-48 (top phase and middle phase) and 220Kv Nellore-Manubolu-II feeder between Loc.No.46-48 (top and middle phases) in EHT lines sub-division, Nellore in SPSR Nellore District
Erection of 5Nos 33/11KV Outdoor Sub-stations along with connected lines, 13KM of 33KV interlinking lines and Erection of 15Nos additional/enhancement of PTRs on partial turnkey basis (PTRs, DTRs, VCBs, HT TVR Meters, and 100/55sqmm AAA conductor will be supplied by APEPDCL) in Jaggampeta Division of Rajamahendravaram Circle of APEPDCL
Rectification of conductor damages in between Loc.No.30-40 (Top phase) of 400KV Krishnapatnam-Manubolu Quad Moose feeder -II and Replacement of Damaged Quad moose jumpers at Loc.No.54, 55 (Bottom, Middle & Top Phases) of 400KV Krishnapatnam-Manubolu Quad Moose feeders -I&II in 400KV Lines Sub-Division, Nellore in SPSR Nellore District
Design, Supply, Erection, Testing, Commissioning of 0.75 km 33kv single circuit line with ACSR panther conductor over proposed 2 nos. special type 220 KV tsp-cs plus 12 towers across Papagni river near Gadikovuru (V) under 33 KV Siddareddygaripalli feeder emanating from 220/33 KV SS Chakrayapeta, Kadapa circle on turnkey basis
Design, Supply, Erection, Testing, Commissioning of 0.75 km 33kv Double circuit line with ACSR panther conductor over proposed 2 Nos. special type 220 KV TSP-CS Plus 12 Towers between Daanavulapadu & Sunnapurallapalli) in Jammalamadugu Rurals Section under 33 KV Ambavaram feeder emanating from 132/33 KV SS Jammalamadugu, Kadapa circle on turnkey basis
IP Based 40KVA ModularUPS, Battery Banks with Battery stand accessories, BMS for 40KVA UPS, IP Based 10KVA Online Conventional UPS, Battery Banks with Battery stand and accessories for 10 KVA UPS, BMS for 10 KVA UPS, 3 Phase Automatic Transfer ... core Power Cable armored, ... core Power Cable armored, ... core Power Cable armored, ... core Power cable armored, ... Sqm Power Cable both ... Sqm Power Cable , ... core Power Cable , ...