Loading…
Loading…
3,392 results • Best match
operating mechanism unit for PCE make VCB, Busbar spout RYB, P.T. 3 Phase 200VA, Vacuum Interrupter Assly, C.T 3.3KV, Rectifier unit 110V, Closing Coil with Assly, P.T. 3Phase 100VA, C.T. 3.3KV, Earth Fault Relay, Spout Bushing Insulator, P.T Fuse, Operating coil 110V, Shunt trip coil, Insulator set complete, IDMT Relay High Set Relay, Auxiliary Contact Switch
Repairing/reconditioning of a Electrical panel make - LandT, sl no.- NIL, capacity- 1250 Amp., 415 volt at new filter plant presently being used for motor pump operation there at Jarangdih colliery.
Providing and fixing of 2 nos. MCCB and different sizes of Lugs in cable of different transformer under Kathara Colliery
Supply and Fixing of 2 nos 800 Amp MCCB DTH for different location s at Topa Project under Kuju Area.
Providing and fixing of surge protection device and MCCB for the protection of 02 nos. weighbridge GVP Ph-II OCP.
Providing and fixing of 630 amp, 415 V, 3 pole MCCB at IR Feeder breaker under KDH OCP, NK Area.
SUPPLY AND FITMENT OF MOULDED CASE CIRCUIT BREAKER(MCCB) 4 POLE, 800 AMP, BREAKING CAPACITY-65KA, RATED VOLTAGE-415V AC,
Fabrication and fitting with bus bar of 800 Amps. MCCB at Alkusa Substation under NGKC for removing of DGMS Violation
Repairing and Replacing of MCCB-01 no 03 Pole 630 Amp 36 KA of Machine Shop under RRS (NK) Dakra
Providing and fixing of 630 Amp MCCB for controlling power supply of Odiya Barack colony under Dakra Project, NK Area.
Complete Repairing/Overhauling and Safety Protection of 400 Amps 2200 Volt Southern Switch Gear Make O.C.B.Switch at 1 No. Bararee as a Main Power Controlling of Lighting Transformer of Bararee Colliery Sl. No. BAR/TRANS/19 Local Id. No. BAR/SW/19.
Maintenance contract of electrical system of HT and LT Switch Gear,HT and LT Motors, HT and LT Cables, LT Bus Duct etc. under BTG, entire Ash package, Plant Water system including Barrage Intake and entire BOP area pertaining 1X500 MW unit
Repairing /Overhauling of 1 No. 400 Amps. 11KV Southern Switch Gear Make OCB Switch Local ID No. KJ/017 for Power Controlling of 1500 KVA 11 KV/3.3 KV Power Transformer at G Patch of Kujama Colliery ( Sl.No. 0682/833) Under Lodna Area.
Repairing of 11kV Andrew Yule make VCB, Sl. No. 3123 of Filter Plant Feeder and VCB Sl. No. 3127 of Feeder No. 10 Controlling breaker installed at 33/11-3.3kV, 22.5 MVA Old Substation of KDH OCP, NK Area
Repairing and maintenance of 3.3 KV, 400A VCB switch make PCE for controlling of 500KVA transformer in Khasmahal and 3.3 KV VCB switch make Andrew Yule controlling of KMP colony at Khasmahal Substation in respect of AKKOCP, BnK Area
Complete Repairing /Overhauling of 400 Amps 3.3 KV Sait Mineline Pvt. Ltd Make VCB Switch Sl.No. SA-1236 and Local Id BAR/SW/VCB/3.3KV/02 at Mari Godown Transformer Room of Amal.NT-ST-JG Colliery under Lodna Area.
Part repairing and maint.of different switches and transformers such as repairing of 6.6KV,400A,VCB, rewinding/repairing electric siren220V, 500KVA transformer, 6.6KV,400A,VCB A/Y make and 11KV,400A,E/T make switch and DC emergency light fitting12V
Repairing of distribution panel of rating 400Amp, Incoming X 12 Nos, 100Amp outgoing for auxiliary power controlling for VCB/SF 6 Circuit breaker AND Maintenance of 630Amp 11KV VCB, Meditron make at 2X10 MVA Murppa substation under Kuju Area.
Repairing of two no HT starter and two no. VCB (3.3KV, 400A) installed at different location of Religara OCP under Argada Area
repair, maintenance n rewiring of the control panel of the 2 Nos. overhead crane (Hoist 10 Ton capacity) and complete repairing and rewinding of the induction motor sl. Nos. -11223108, KW18.5, 415v, 970 RPM, of Rajrappa Washery Project.
A. Repairing of 100HP Haulage Control Panel 550Volts, Sl.No.6352 for controlling of Benidih Underground B. Repairing of 300Amps OCB switch 550Volts, Erskine Heap make controlling of Feeder Breaker 02 main switch of Phularitand, AMP Colliery.
Work of shifting of fabricated lighting tower and fixed type high mast lighting tower with control panel and other fitting at different locations of mines for proper illumination of working zone under Dakra OCP, NK Area
Supply and fitting of Bucholz Relay, Winding Temperature Indicator and oil Temperature Indicator with complete control panel with necessary relays with tripping circuit 2MVA transformer 11KV/3.3KV at the Mld 20/21 Pits new Gul Bazar
Repairing of control panel switch, make-L and T (Sl. No. AT72636) at Intake Konar Riverside CPP Pump House for controlling 02-Nos. vertical pump operating which feeds raw water for filter plant under Kathara Colliery.
Repairing and reconditioning of 02 nos. VCB Field switches 3.3 KV, make- Electro Technica at Ashok OCP.
Repairing and reconditioning of PCE make and yule make vcb at Laiyo Substation JOCP under Hazaribag Area
Procurement of Flat Contact 800 Amp for 11KV VCB Material Copper and Moving Contact Bar Cat/K321
Repairing of 3300Volt, 400Amp VCB having make-Electroteknika and Sl.No.-15018 at Main Substation of Bhurkunda Colliery.
Repairing of 11kV-400A Electro-Technica make VCB sl.no.M-5049 at Dahibari sub-station of Dahibari colliery.
Repairing of Float Isolator and VCB assembly in EKG-5A shovel at Tapin North OCP, Hazaribagh Area
Repairing and reconditioning of 400 Amp, 3.3 KV Prabhu make VCB at Gidi Washery under Argada Area.
Complete repairing of Electroteknica Make , 400A,3.3KV,FLP,VCB having SI.No.FCB158 at Maheshpur Colliery under Govindpur Area.
REPAIRING OVERHAULIN OF VCB SWITCH 400 AMPS,MAKE ELECTROTECHNICA YULE,SL.NO.SG12311 AT NKAS SUB-STATION KATRAS AREA..
Repairing of Electroteknica make 3.3kV VCB 400Amp SL No. FACB663, brought from EBC at ADIC, Kusunda Area
Repairing of 01 no. VCB of 11 KV, 800 Amp. Andrew Yule make at DCW Sub-station.
Repairing of 400AMps 11KV VCB installed at IV seam sub-station of ABG Colliery under Govindpur Area
Repairing and rewinding of potential transformer 6point6KV 110volt VCB starter of SOCP patch Muraidih under AMP Colliery
Repairing of 11kv 400 amps electroteknica make VCB of sl.no. m-5054 installed at godhur switching substation
Complete Repairing of 400 Amps 6.6KV Andrewyule Make VCB Switch Controlling at New Pit Sub Station AEBSC
Repairing of 11KV,400A VCB electrtecnia make swatch SI.No SGI12314 of IV seam sub station of ABGC
Repairing and reconditioning of 3.3KV, 630Amp Electrotecnika make VCB at main substation of JOCP under Hzb Area.
Repairing and reconditioning of 3.3KV 400A VCB of make Prabhu Sl No 020-2004 of Sirka Colliery
Repairing of 400A, 11KV VCB Make Meditron S. No- MDO-0329 of Victory Section Under Bastacolla Area.
Work of shifting of VCB at Colony no. 04 substation from Regional Sub-station of Kathara Colliery
Overhauling and upgradation of protection system of 11KV VCB, make- Electrotechnika, Sl. No.ET4219 GM unit, Piparwar Area.
Repairing of VCB of 1000 KVA Transformer installed at Elecon Feeder breaker under KDH OCP, NK Area.
Complete repairing reconditioning One No. 3.3 KV 630 Amp. VCB Switch installed at PEOCP under Hazaribagh Area
Repair and reconditioning of 02 nos. VCB installed at different location of Sirka Colliery under Argada Area
Towards repairing of isolator and VCB assly. in HMB 554 Shovel at Tapin North OCP, Hazaribagh Area
Repairing of Isolator and VCB assembly of EKG 5A shovel Sl. No. 563 at Tapin North OCP.