Repairing and re-conditioniong of 3 Nos 630 Amp, 6.6 KV Siemens make VCB Sl. No. 8323, Sl. No. 8329 and Sl. No.- 8325 at Kedla Washery under Hazaribag Area.
Maintenance and reconditioning of 400Amp 3.3 KV Rey roll burn make OCB and 800Amp 11 KV meditron make sl no- 7486 VCB at site of Topa Project under Kuju Area
Repairing of 11kv,400amps,VCB switch Electronica make,type NFLP Sr.No.SGI-9039 near Colliery workshop,controlling of 11kv/440V lighting transformer ,feeding power to workshop and company quarters and village
Repairing of main 11KV VCB, 800 Amp SI No. 6079, make Meditron for controlling of 7.5 MVA Transformer and switch of main A.K Saunda Sub-Station at Central Saunda Colliery.
Repairing/overhauling of 11KV/400A, VCB switch with bus bar make Andrew yule for main controlling of 11KV/3.3KV, 1500KVA transformer installed at Alkusa Sub-station, under NGKC, Kusunda Area.
Power contactor 3 pole, AC3 rating 25 A, Power contactor 3 pole, AC3 rating 40 A, Power contactor 3 pole, AC3 rating 70 A, Power contactor 3 pole, AC3 rating 110 A, Power contactor 3 pole, AC3 rating 200 A, Spare kit ML-3 Contactor
PROVIDING AND COMMISSIONING OF FIRE PROTECTION SYSTEM OF MICROPROCESSOR BASED AFDS AT 6.6KV CHP HT PANEL ROOM OF RAHMAHAL CHP
Preventive Maint./rep. of (A)1600KVA, 11kV/3.3kV, 84/279.92A, Power Transformer, Make Transformer and Switchgear Ltd, Madras India, Sl.No.10203 and (B) 3 MVA, 11kV/3.3kV, Power Transformer, Make GEC, Sl.No. Missing installed at Substn under Dakra OCP
i) Asst to maint and opnl activities of elect equipment associated with BTG Control Room Generator Pedestal Lighting installations and equipment of AHP of Bokaro TPS. ii) Assist to maint work i.r. of 6.6KV 415V Switchgear panels Battery charger etc
REPAIR AND MAINT OF STAND BY DG SETS, CONTROL PANELS, SWITCH AMF AND PANELS AND OTHER CONNECTED WORKS AT TBRL RANGE RAMGARH
INSTALLATION OF 9(NINE) NOS OF CHEMICAL EARTH PIT FOR TRANSFORMER, SWITCH, PUMP MOTOR, AB SWITCH AT 192 UNITS, 108 AND 360 NO. COAL DUMP SUB-STATION OF MCCB AT COAL DUMP UNDER KATRAS AREA
Construction of Residential Building (Type-II-80 Nos., Type-III-24 Nos., Type-IV-04 Nos. and Type-V-02 Nos.) for 40th Bn. ITBP, Sukurhutu, Kanke, Ranchi. (SH: Providing electrical panel alongwith service connection cable from existing JBVNL 500 KVA DSS to newly constructed residential Qtrs. of ITBP, Ranchi)
Repairing of Earth Leakage Relays of ROK-6 Switchgear
Jointing the 11 KV power cable of 3 core 95 sq. mm Aluminum conductor near stacker one (1701) for power supply from 14 no. feeder (RMU) of 4211 main sub-station to 11 KV /3.3 KV Transformer installed at 4212 Sub-station under CHP-CPP, Piparwar.
Supply of Power Contactor and MCCB
Providing and fixing of sensitive earth leakage relay and space heater in 11 Nos. Meditron make VCB Panel 1250 Amps, 3.3 kv installed at CRO Substation under Churi Colliery, NK Area
33KV VCB breaker Limb replacement and 33KV Current transformer dismantling installation including testing commissioning associated with other miscellaneous work in overhead line at Madhuban DG Sub-station under Block II Area
Complete repairing of 11KV/400A VCB HT Switch Make-Electro Teknica Sl.No-8371 for controlling of incoming power supply of 1250KVA transformer of Pure Benidih underground Phularitand, AMP Colliery, Barora Area.
Repairing of VCB field Switch make Electrotechnica and Electric Turning Joint, Outdoor Transformer, Power Supply unit and Vacuum Contactor of CK300 shovel Sl No-E172 deployed at Topa OCP, Kuju Area
Partial repairing of 3.3 KV, 400A, Sl. No. 067, Make Andrew Yule VCB, secondary switch of 3MVA (11KV/3.3KV) Transformer installed at Quarry No. 02 Substation under Purnadih OCP, NK Area
Complete Repairing and Overhauling of 400 Amps 3.3 KV Mainline Make VCB Switch local ID. No. SW/52 for Power Controlling of TSU(Transformer)at N.S. Lodna Workshop under Lodna Area.
Complete repairing and reconditioning 02 Nos. Electrotecknika make 3.3 KV 400 Amp. VCB Switch, S.l no.-ET-4056 and ET-4049 installed at parej filter plant of PEOCP under Hazaribagh Area.
Making of 02 No. Transformer shed and 01 No. foundation for VCB with earth pit for Indoor type Transformer at Regional Store and Parej filter plant of PEOCP under Hazaribagh Area
Repairing of 3.3KV VCB, 630Amp, make Andrew Yule, SI. No. 0360 used as controlling breaker of 3.3KV OH Line of Jarjara Feeder and 600 KVAR Capacitor bank (Lighting) under Urimari OCP.
REPAIRING OF SAFETY PROTECTION AND ON/OFF MECHANISM OF VCB SWITCH 6.6 KV, 400 AMPS, MAKE - ANDREWYULE, SL.NO.951, MAIN CONTROLLING 5 SEAM SUB STATION AT SALANPUR COLLIERY UNDER KATRAS AREA
Complete Repairing and Safety Protection of 400 Amps 3.3 KV Electrotecnika Make VCB Switch for J.G OCP Local Id. No. BCCL/JGOCP/FLP/ JN-58 of Amal. NT-ST-JG OCP.
COMPLETE REPAIRING OF 400 AMPS, 6.6 KV, VCB SWITCH MAKE REROLBURN CONTROLLING FOR 550 KVA , 6.6 KV/440 VOLT LIGHTING TRANSFORMER AT 6 PIT KCC SUB-STATION UNDER AGKCC, KATRAS AREA
Intermediate Overhauling (IOH) replacement kit for Single Bottle VCB of M/s BT, consisting of 14 items as per annexure attached. Type BVAC 25.10M07, Kit No. 3EYC400261-R1 (Part No-VIOH)
IOH replacement kit for Single Bottle VCB of M/s AAL Type VCBA 25. 10. TR. Part.no.-4300007100/32, Specn Part no.4 consisting of 20 items as per annexure attached.
Concreting / grouting , painting and earthing of 28 nos. lighting pole and neutral earthing body earthing of 3.3KV VCB and 630 KVA Transformer at Sangam Vihar Colony under GM unit, Piparwar Area.
Repairing and reconditioning of 3.3KV 400 Amp Sl. No. MD-0420 Meditron make VCB switch installed at main substation for feeding power to feeder No 1 at TNOCP under Hazaribagh area
Oil filtration, oil testing and maintenance of all the transformers installed at Ara Colliery and cleaning and painting of all the VCB and OCB installed at Area Colliery under Kuju Area.
Repairing of 2nos. Induction motors 110KW, 3.3KV 1490RPM marathon make and 2 nos. 3.3KV grade 100A, sait main line make VCB DOL starter installed at mine of Tarmi OCP, Dhori Area
Repairing and reconditioning one no. 800Amp. Meditron make VCB switch sl.no MOD 0416 use for primary control of 1.6 MVA transformer installed at Main substation of Topa project under Kuju Area.
Complete Repairing/ Overhauling of 3.3 KV/VCB Switch of Electrotecnica Make Sl.No. VCF-1174 Local Id. No. BAR/SW-25 at Bararee S/C of Amal. Joyrampur Colliery Under Lodna Area
Repairing and reconditioning of 11KV VCB PCE Make 11KV OCB Crompton Greaves Ltd make installed at main substation for primary control of 1 MVA 1.5MVA Power transformers of KUGP Hzb Area
Repairing/ Reconditioning of 02 No, VCB, Prabhu make, 6.6KV, 400A SL No. 043/2004 and 036/2006 installed at Bheda River Pump House and BTS Pump House in Township Rajrappa Area
Repairing and overhauling of 5 nos. 3.3KV grade, VCB starters of different type and make attached with 2000 GPM and 1000 GPM pumps installed at different places of AADOCM, Dhori Area
COMPLETE REPAIRING OF SAFETY PROTECTION AND ON/OFF MECHANISM AND OVER HAULING OF 400 AMPS.6.6 KV,VCB SWITCH, MAKE - ANDREWYULE, SL.NO.2911 AT KATAPAHARI SUB-STATION UNDER AKWMC KATRAS AREA
Installation of 1500 KVA 11KV 3.3KV M and B make power transformer Sl. No. 1210470 with 11 KV and 3.3KV 400amps VCB at MOCP sub-station of Muraidih colliery Barora Area.
Complete Repairing of 3.3 KV 400 Amps VCB Star-Delta-Starter Make Set Sl.No.- SA646 Installation by Joria Controlling of 4000 GPM Pump and Motor at Kujama Colliery Under Lodna Area.
Repairing of i) 11KV, OCB 400A, Sl. no. 02 (Local), make Biecco, ii) Installation and commissioning of 03 nos. VCB, 400A, 11KV, Sl. No. a) 116-1956, b) 2847 c) 9030
Intermediate Overhauling (IOH) replacement kit for Single Bottle VCB of M/s BT, consisting of 14 items as per annexure attached. Type BVAC 25.10M07, Kit No. 3EYC400261-R1 (Part No-VIOH)
Intermediate Overhauling (IOH) replacement kit for Single Bottle VCB of M/s BT, consisting of 14 items as per annexure attached. Type BVAC 25.10M07, Kit No. 3EYC400261-R1 (Part No-VIOH)
Custom Bid for Services - Supply installation of current transformer Amp meter Selector switch and Volt meter field switch and repairing of 66KV 630 Amp VCB in Lalmatia SubStation at Rajmahal OCP
Erection of LTOHL by converting existing HTOHL into LTOHL, shifting and installation of a lighting Transformer with its switchgear, at Sub-station of QNo. 01 as req for supplying power to Road WB No. 01 and illumination of transportation road
Installation of 500KVA, 3.3kV/440V Transformer with its primary control switchgear at Stock No. 10 and 630 KVA, 6.6kV/440V Transformer at Stock No. 21 for providing power to M/s Madhucon for CHP construction work under KDH OCP, NK Area
(i)Assistance to maintenance work in respect of HTLT Switchgear Panels, HTLT Motors, 415V MCCs, and Telephone Exchange and other Elect Installations(Total 03 nos Labour engaged for said Job). (ii)Assistance to operational activities of CW Pp House, B
Providing and fixing of NGR for 02 Nos. 1.6 MVA, 11kV/3.3kV Make Transformer and Switchgear Ltd (Sl. No. 10202 and Sl. No. 10203) installed at Main Sub-station for DGMS compliance of Regulation 103 (1) under Dakra Project, NK Area
Repairing of OCB Switch 550V 200Amp Sl No 62543 make Switch Gear and Cowans of Excavation Work Shop Mine A Bhurkunda Colliery