REPAIRING /OVERHAULING OF MECHANICAL ASSLY OF 1250 AMP ,33 KV VCB MAKE BIECO LAWRIE SL NO PVCB -36-0014 ,33 KV RAMKANALI MAIN CONTROLLING BREAKER AT 33 KV RAMKANALI REGIONAL SUB-STATION UNDER KATRAS AREA
Repairing fitting and testing of IDMT Relay and EL Relay of VCB switch Make Meditron BIT Mesra 11KV 1250Amp. Sl. No MDO 0337 CTR 150 300 5 5A controlling switch of AC feeder of BPH.
Complete repairing and overhauling of 11KV, 400 Amp VCB Sl. No. - MDO-0330 MEDTRON make for controlling 750 KVA Transformer for F/B 02 and 03 at Kessurgarh of ABOCP Mine under Block-II Area
Complete repairing of 3.3 KV VCB Switch 800 Amp. Outdoor type make Andrew Yule Sl. No. 1359 installed at Rohini Main Substation for secondary control of 3MVA Transformer in respect of Rohini Project, NK Area
Installation , Relocation of 04 nos transformers (1. 300KVA, 3.3KV/500V ,2. 630KVA, 3.3KV/500V,3. 500KVA, 3.3KV/500V, 4. 100KVA, 3.3KV/440V) and 03 nos VCB/OCB and providing Busbar arrangement at IWSP BnK Area
As per NIT
Repairing of power distribution board of PDB(13) PDB(11) PDB(5A) and PDB (12A) of Main workshop complex
RCC drain from Jawahar navodaya school to Vijay house Laying of Paver block from subhash chowk to palamu club road and ACB ground hume pipe near ACB office Under Medininagar Municipal Corporation.
For installation and commissioning of 400Amps switch gear 04Nos of JVS make type JRC-066 over current relay at Mudidih Colliery Sub- Station under Sijua Area
Misc. repairing of electrical panel, Electrical motor connecting cables of BWF feeder Breaker at CP Siding, GRD Project.
Repairing of 02 no 3.3 KV, 630A Make - Mine Line with providing / replacement of 03 no VCB Interrupter and other safety related accessories works of another same capacity switch in line with OCP Mine Feeder associated domestic feeder, GRD Project.
Onsite repairing of 2 nos of 3.3 kV grade 400 Amps Circuit Breaker i) PnM No-62 for control of pump feeder at DD mines substation ii) PnM No 48 for primary control of 500KVA 3.3KV/440V transformer and 3 nos of secondary 440 Volt controlling ACB sw
procurement of Cable reeling drum for tong as covered as per Technical Specifications., procurement of Air condition system for Electrical panel cabin as covered as per Technical Specif, procurement of Terminal box on bridge and main ... Lighting distribution board as ...
Procurement of BRKR,CRCT,MCCB,1200A,415V,4P etc.
Bushing, MCCB, Cable Jointing Kit, Preventor, Hose, Lifting Machine
Procurement of MCCB 4 POLE 800A 415V AC etc.
Complete Repairing of 3.3 KV 400Amps Main Line Make Pump Starter Flame Proof Vacuum F.L.P. VCB Starter Controlling of Pump and Motor of A-NT-ST-JG OCP Local Id. No. BCCL/NT/SW/3.3KV/59.
Providing and fitting of control wiring of power bank of two switches of 3point3KV 400amps VCB Andrew yule make switch and 11KV 800amps OCB switch GEC make controlling of fire area workshop substation of Damoda Colliery
REPAIRING AND OVERHAULING OF MECHANICAL AS WELL ELECTRICAL ASSLY OF 1250 AMP. 33 KV VCB MAKE - BIECCO LAWRIE SL.NO. PVC - B36 - 0021 (TR - 2 C ONTROLLING BREAKER) AT 33 KV R.S. SUB-STATION UNDER KATRAS AREA
Installation of 04 nos. of 11kV, 1250A, VCB, Meditron make with provision of incoming and outgoing connectors earth leakage relay with CBCT at 33/11-3.3 kV, 22.5 MVA Old Substation of KDH OCP, NK Area
Repairing and Maintenance of 500 KVA, 11KV/440V Distribution Transformer make Servokon, Sl. No- 2021/04/08/11 and Repairing of 11KV, 400 Amp VCB, Make- Electrotecknica, sl no- SP/1/511 at Central Hospital, Ramgarh
Providing Proper earthing for 3.3KV 800 Amps, VCB, 630 KVA, 3.3KV/440 volt transformer at DG set campus at Sangam Vihar Colony and 100KVA , 3.3KV/440 volt Transformer at CISF camp under GM unit, Piparwar Area.
Installation of Negative sequence relay of 400 Amps 3.3 KV Yule Make Sl.No. 3836 VCB Switch for KT New Sub-Station Secondry controlling 3.15 MVA Power Transformer of Amal. NT-ST-JG Colliery under Lodna Area.
Repairing and reconditioning of 02 nos 3.3KV, 400A VCB mine line make for controlling of 200KVA 3.3KV/415 lighting transformer and primary controlling of 3.3KV (150X2)KVAR capacitor bank of main substation respectively at Karma Project
fitting and testing of IDMT relay and EL Relay of VCB switch make Meditron BIT Mesra 3.3KV 1250Amp. Sl. No. MDO0340 CTR150/300/5 5A primary controlling switch of 3.15 MVA transformer under Bhowra Power House.
Onsite installation of main controlling switch 800Amps AB switch and VCB 11KV grade for feeding power to main bokaro feeder 11KV with repairing and reorganization of busbar at 33KV sub station Konar Exp OCP, BnK Area
Partial Repairing /Overhauling of 400 Amps 11 KV VCB CTR-100/5 Amps Make Meditron Serial no-6351 ,Local ID-BCCL/JG/SW/400 A/36 at Bagdigi Colliery of Amal. Joyrampur Colliery under Lodna Area.
(1)REPAIRING AND OVERHAULING OF MECHANICAL AS WELL ELECTRICAL ASSLY OF 1250 AMP.33KV VCB MAKE-BIECCO LAWRIE SL.NO.PVC-B36-0021(TR-2 CONTROLLING BREAKER) AT 33KV R.S.SUB-STATION.(2) NEW INSTALLATION OF 1000 AMPS V.C.B
Complete repairing/ reconditioning of 3.3kV VCB switch 200Amp. Outdoor type make- Elecrotechnika, Sl. No.- VIB-M-5025 to fit in colony feeder for Controlling new expansion (0.75MTY) 3.3kV power in respect of Rohini Project, NK Area.
Repairing and maintenance of 3.3KV grade 2 x 150 KVAR three phase automatic power factor controller and 3.3KV VCB switch Meditron make, Sl. no. MDO/504, 400A installed at Kalyani Sub-station under SDOCM, Dhori Area.
Repairing of 02 nos circuit breaker one no 11KV 400 Amps meditron make and one no 3.3KV grade VCB mine line make installed at Gandhi nagar and D.D mines sub station in respect of Bokaro colliery
Construction of 132 kV One no. Railway Hybrid Switchgear type Bay including extension of 132 kV Main Bus at 220/132 kV GSS, Madanpur and 132 kV S-C 2 phase Transmission Line on DC tower from 220-132 kV GSS Madanpur to Railway TSS, Dumka
Construction of 132 kV One no Railway Hybrid Switchgear type Bay including extension of 132 kV Main Bus at 220-132-33 kV GSS, Jasidih and 132 kV SC 2 phase Transmission Line on DC tower from 220-132-33 kV GSS Jasidih to Railway TSS Deoghar
Repairing of 01 no PnM 12, 550 V 100 Amp make Reyroll burn switch b. Repairing of 01 no PnM 49 550 V Drill panel c. Repairing of 01 no PnM 11 550 V OCB
SHUNT TRIP_SERIES TRIP COIL, 11KV_110V, 100VA PER PHASE 3 PHASE PT, RESIN CAST CT CLASS_ 5P 10_ CLASS 1.0, MASTER TRIPPING RELAY, SHUNT TRIP COIL ASSY. 110V DC, BREAKER CHARGING HANDLE, AUXILLARY SWITCH ASSEMBLY 4NO + 4NC, 3.3KV GRADE RESIN CAST POTENTIAL TRANSFORMER, RECTIFIER CAPACITOR UNIT _ 15A, 3.3KV, 3AMPS P.T. FUSE, 3.3KV GRADE RESIN CAST POTENTIAL TRANSFORMER RATIO_ UP TO 300_5, 10VA, CI_1 5P10, EARTH LEAKAGE RELAY, FRONT OPERATED MANUAL TYPE CHARGED MECHANISM
CIRCUIT BREAKER 1200A, 415V, 4PL, 3P, MCCB With enclosure, MCCB RETED CURRENT 200AMP/415V PART NO- TCHT0200, CABLE LUGS, CABLE SOCKET, LT WIRE 8MM AUTOPAL
Complete Repairing /Overhauling of 2 No. Mine Line Make ACB Switch 550 Volt (i) 400 amps Sl. No. 5497 Local Id. Joy-5 SW-9 (ii) 300 Amps Sl. No. 5474 Local Id. Joy-5 SW-14 of 150 H.P. Motor Pump at Joyrampur water Plant of Amal.Joyrampur
SUPPLY AND FIXING OF PVC INSULATED MAT AROUND THE CONTROL PANNEL AT 33KV DHANKUNDA SUB-STATION AND DIFFERENT LOCATION OF SWITCH/GEAR STATION AT URJANAGAR RAJMAHAL AREA
Installation of 05 Nos. outdoor type VCB with reorganization of Bus Pipe system of 3.3 KV and renovation with bus pipe system of 03 MVA, 11KV/3.3KV Power Transformer at Main Sub Station Religara under Argada Area.
Providing and fixing of 3.3 KV VCB CPP control cable with remote control switch and 11 KV KTC new line control cable with remote control switch and providing of earth fault over lead relay under Kathara Colliery
complete Repairing of 11KV VCB Andrew Yule Make,400A, Indoor type, CTR-200-100/5A-5A, Sl. No.- 5581 Primary controlling of 1.5 MVA 11kv/3.3 kv Transformer Bhowra Power House approval for DGMS Bhowra Power House
Installation and commissioning of new safety devices in 6.6 KV, 400 amp and 200 amp make Electrotechnica and A/Y (03) nos VCB installed at site of PB Project Colliery colony sub-station for supplying lighting line.
Complete Repairing of 3.3 KV 400Amps Mine Line Make Pump Starter Flame Proof Vacuum F.L.P. VCB Starter Sl.No. HT.SD-13 Controlling of Pump and Motor of A-NT-ST-JG OCP Local Id. No. 17(JN-17)
COMPLETE RELPAIRING AND REWINDING OF POTENTIAL T/F 6.6 KV/110V AND P.T ADOPTER FIXING OF 400A VCB 6.6 KV ELECTROTECHNIKA MAKE INCLUDING ALL MATERIAL AND LABOAUR CHARGES AST DECCO SITE SUB-STATION UNDDE AGKCC KATRAS AREA
(A)Complete Repairing and Overhauling of 01 No. 3.3 KV 650 KW VCB Star Delta Starter Mine line Make Sl.No. 242 and (B)Sl.No. 243 (C)Sl.No. 238 of Amal. NT-ST-JG Colliery under Lodna Area
Supplying and fitting of 33 KV VCB with 33 KV C.T. and P.T. and renovation of Electric Sub-Station (33/11KV) with its all components for Booty Pumping Plant under D.W. and S. Mech. Urban Division, Ranchi.
Repairing work for (a) maintenance and reconditioning of Field Switch 3.3 KV VCB 630 Amp. Make Transgietz Enterprises and (b) repair of LVCR assembly and (c) welding transformer of EKG Shovel Sl. No. 592 of Jharkhand OCP.
Complete Repairing and Safety Protection of H.T. Switch 11 KV 400 Amps Andruyule Make VCB Switch Sl. No. 2927 Local I.D.JOY-3/Sw/1 for Power Controlling of Lodna-2 Main Switch at Joyrampur Colliery at site.
Complete repairing and overhauling of 01 No 3.3 KV 650 KW N-FLP Mine Line Make VCB Star Delta Starter SL. No.238 at Jeenagora old pumping patch of Amal. NT-ST-JG OCP Under Lodna Area.
(A)Repairing of One(01) No.1200Amps 550Volt G.E.C. OCB Switch Sl.No.50/0109 and Local ID.No. Joy/05/Sw/OCB/550V/07(B) H.T. Switch 3.3 KV 200 Amps Andrewyule Make VCB Switch Sl.No. VFHT 1161