Panel Light Bulb-IS 1601, Light Emitting Diode LED Fixture- LED tube light
LED Well Glass Fixture (Q3), Led Luminaire (For Flood Light)-IS:10322, IS:16107 (Q3), Led Street Light (Q3)
Babble Shol, Silk Ribbon, Gift paper, Ribbon White, Ribbon 1 inch, Cable Wire 16mm 2 core, Flexible Roll, Insulation Tape, Clip 12mm, Bit Drill, PVC Grip small, PVC Grip Large, Screw 5mm, Screw large, Adaptor For Quad Copler, Power Supply Board, LED ... Ladi, LED Light Hanging, ... mm, LED Bulb ,
Service Cable 10mm 2 Core, BC Parallel Holder, LED Bulb 9W, Bed Switch, Change Over Switch 63 Amp Belno, Electrical Board 15 Amp
LED Luminaire (For Road and Street Lights) LED Luminaire (For Road And Street Lights) ( 250 ) Technical Specifications Specification Specification Name Values Allowed Values STANDARDS LED Luminaire conformity to IS:10322/Part 5/Section 3/2012 latest ... of LED Luminaire as ... each LED luminaire unit ... - LED Luminaire for ...
LED Luminaire (For Road and Street Lights) LED Luminaire (For Road And Street Lights) ( 200 ) Technical Specifications Specification Specification Name Values Allowed Values STANDARDS LED Luminaire conformity to IS:10322/Part 5/Section 3/2012 latest ... of LED Luminaire as ... each LED luminaire unit ... - LED Luminaire for ...
Electrical Signal Exchange System for Three Phase Locomotives as per Modification Sheet No.RDSO/2018/EL/MS/0470. Each system consists of -(i) Two sets LED lights. (ii) Operating Panel / Switches for Loco pilot and Assistant Loco pilot separately and (iii) Harnessed cable for connection to CLW Specn. No. CLW/MS/03/0670 Alt-1.
LED light fitting of 60W, 120W, 200W and HPSV lamp of 400W for proper lighting of Houl raod, 2 No. and 3 No. quarry at mines to maintain minimum lux of light to avoid DGMS violation at different places of mines at Kathara Colliery.
REPAIR MAINT INCL FILLING OF JOINTS AND CONNECTED ITEM IN RUNWAY AREA, B/R AND E/M NATURE OF HANGER AND PERIODIC PAINTING OF RUNWAY AT 1 (I) AND RO FLT AND REPAIR/ REPLACEMENT OF DAMAGED, SWITCHES, SOCKETS, LED LIGHT FITTINGS, SUBMAIN WIRING, UNSV A
Maintenance and Construction of Boundary wall and Roads and providing electrical bulk services with UG cable along with octagonal pole with LED light for JNV campus, including Essential feeder pillar, non essential feeder pillar, street light feeder pillar, earthing etc for JNV Sahibganj, Jharkhand
MOVABLE SELF STANDING LIGHT POLE WITH LED LIGHT AT DEP RANCHI.
LED Corn Lamp, 30 Watt, Operating Voltage Range- 90-110 V AC, 50Hz, 2 x 2 Feet 10 Watt Underground mining Type Tube Light, 100 Watt LED Flood Light, Operating Voltage Range- 110V AC± 10%, 50Hz
Water Overflow Alarm, Nylon Cable Ties 2.5 mm, Wire Cotton Sleeve 0.75 mm, Wire Cotton Sleeve 1 mm, Wire Cotton Sleeve 1.5 mm, Wire Cotton Sleeve 2 mm, Wire Cotton Sleeve 2.5 mm, Wire Cotton Sleeve 10 mm, Combined Board 15 amp, Wire Clip 4 mm, Nose ... Plier, LED Tube Light ... mm, LED bulb 9 ... Watt, LED bulb 23 ...
LED Luminaire (For Road and Street Lights) LED Luminaire (For Road And Street Lights) ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values STANDARDS LED Luminaire conformity to ... of LED Luminaire as ... each LED luminaire unit ... * LED Luminaire for ...
LED Luminaire (For Road and Street Lights) LED Luminaire (For Road And Street Lights) ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values STANDARDS LED Luminaire conformity to ... of LED Luminaire as ... each LED luminaire unit ... * LED Luminaire for ...
LED Light fitting with Luminaire for Doorway / Gangway Area for LHB Type AC Coaches Type N (9 watt), as Per Drawing No. LW76099 alt 'b' or latest Conforming to RDSO Spec. No. RDSO/PE/Spec/TL/0091-2016, Rev-1, with RCF Annexure 1,2 & 3 or latest
CAMC for erection of 230V LTOHL req for illumination along the side of haul road with supply-fitting of LED light fittings alongwith its safety/security, rep and maint of the OHL structure as req for next two yrs at QNo. 01 under PND OCP, NK Area
A. Erection of pole and dismantling, laying of PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade of 240 sq. mm for river side 140 KW motor 550 volt, DSM pump and transformer (LT side) B. Dismantling and installation of 60 Watt LED light
Portable Convection kerosene heater (Q3), Kero Room Heater (Q3), Stainless Steel Hot Tiffin Box-IS 5522-1992 (Q3), Kerosene oil fired bukhari complete with exhaust pipes (MHA) (Q3), Led Flood Light (Q3), Solar Lamp (Solar Study Lamp) (Q3)
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - COAL MINES; Electrical System or Installation, Providing fixing of 03 nos lighting tubular poles with 04 nos of 350W LED flood light for the illumination of Magazine si..
HARPIC 500 ML, LYSOL FLOOR CLEANER 500ML, ACID FOR TOILET USE 500 ML, DETTOL ANTISEPTIC LIQUIED 250 ML, DETOL HAND WASH 180ML, TARPIN OIL 500 ML, BRASSO METAL POLISH 400 ML, RED HIT, BLACK HIT, NAPTHALIN BALL, ALL OUT MACHINE, MOP STICK FOR FLOOR ... CLEAN, LED BULB 9W, ... 9W, LED BULB 10W, ... 10W, LED BULB 12W, ... 12W, LED BULB 14W, ...
Panel Light Bulb, Light Emitting Diode LED Fixture- LED tube light Experience Criteria 1 Year (s)
XLPE Cable for Working Voltage up to and Including 1.1 KV Marked To IS 7098 (Part 1) (Q2), LED Luminaire For Floodlight Conforming To IS 10322 (Part 5/Section 5) (V3) (Under BIS Scheme - II) (Q2), PVC Insulated Copper Cable Single Core and Multi Core ... ( LED Bulb ) ... (Q2), LED Luminaire For ... (Q2), LED Luminaire (Recessed ...
For Erection of 4 nos. Pipe poles, Lighting Arrester with earth pit for safety of electronic equipment from thundering /lightening at Tetulamri weighbridge and erection of 3 nos. Pipe Pole for installation of LED Flood Light at Bansjora Weighbridge
Hiring of Earth Moving Equipments, Material Handling Equipments and Cranes (per Hour basis) - As Per Buyer's Requirement; Mini Truck mounted telescopic tilting lighting tower of 7mtr long with DG Set 08 nos 400W LED Flood Light fittings; Mini Truck ..
LED Luminaire for Road and Street Lights (V2) Conforming to IS 10322 (Part 5/Section 3) (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Experience ... category LED Luminaire for ...
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Coal Mines; Providing and fixing of 04 nos lighting tubular pole with 05 nos of 350KW LED flood light for the illlumination of Hizukita village KH and lalmatia lohari to..
LED Luminaire for Road and Street Lights (V2) Conforming to IS 10322 (Part 5/Section 3) (Q3) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No Document required from seller Certificate ... category LED Luminaire for ...
S/R to E.I in Room no.-35, 14, 206 at Nepal Hosue, R.No.-139 in Yojna Bhawan, Repla. wall fan in differ. rooms and corr., Repl. of LED light and wall fan in NIC at Yojna Bhawna and Repl. of Service cable, wall fan in Rajaj Rani Kothi, Doranda, Ranchi
SPL REP BLDG NO T-15A(OFFRS MD ACCN)AT KURUKSHETRA LINE, REWIRING AT BLDG NO T-2 AND T-5,PROVN OF LED LIGHT, CEILING FAN AND EXHAUST FAN A/W ACCESSORIES AND NEW TOILET BLOCK(03XWC AND 01 WASH BASIN) INCL SEWAGE SYS AT RAMESHWARAM LINE UNDER GE RANCHI
Book Set for Library, Bookshelves, Table, Chair, Flooring, Art Wall Painting, Ceiling Fan, Led Bulb, Curtain, All in One PC, Reception Table, Wall Watch, Wrold Globe, Photo Frame
Led Rope, Led Light 10 Mtr Bundle, Led Strip 40 Mtr, Wall Lamp Double side
MOBILE TYPE HIGH MAST LIGHTING TOWER (18 mtr. ), 10 KVA TRANSFORMER WITH LED LIGHT FITTINGS
Self Ballasted LED Lamps for General Lighting Service as per IS 16102 (Q2), LED Tube Light (Retrofit Type) (Q2)
LED Driver, input watt 18 W, voltage 110 V AC/DC, Voltage range 90-140 VAC/DC, Rated output voltage: 24 V, suitable for 18W LED light fitting for passenger area (cabin side) for LHB AC coaches Type-L as per RDSO spec. No. RDSO/PE/SPEC/TL- 0091-2016(Rev.-1 ).
SEEK JHADU, PHOOL JHADU, HARPIC 1LTR, LED BULB 23WATT, LED BULB 30WATT, TORCH LED 3 CELL, CELL BIG, TEJAB YELLOW PER LTR, PHENYL 1LTR, GAITI, FAVDA, KHURPI, HASSIYA, KULHARI, KNIFE BIG SCISSOR, CHUNA POWDER PER KG, CHARCOL PATHER PER KG, LAKRI GUTTKA ... BINDING, LED BULB 5WATT ... CONSILD, LED BULB 7WATT ...
LED Luminaire for Road and Street Lights (V2) Conforming to IS 10322 (Part 5/Section 3) (Q3) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No Document required from seller Certificate ... category LED Luminaire for ...
LED Luminaire for Road and Street Lights (V2) Conforming to IS 10322 (Part 5/Section 3) (Q3) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No Document required from seller Certificate ... category LED Luminaire for ...
LED Luminaire for Road and Street Lights (V2) Conforming to IS 10322 (Part 5/Section 3) (Q3) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No Document required from seller Certificate ... category LED Luminaire for ...
Supply, Installation, Testing and Commissioning of 25 meter High Mast Light with LED lighting system for Coal Mining Projects (PBCMP, KDCMP), Hazaribag
LED Luminaire for Road and Street Lights (V2) Conforming to IS 10322 (Part 5/Section 3) (Q3) MSE Exemption for Years Of Experience and Turnover Yes | Complete Startup Exemption for Years Of Experience and Turnover Yes | Complete Document required ... category LED Luminaire for ...
Experience with Gov. Required 2 Year (s) LED Luminaire (for Flood Light) ( 360 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values STANDARDS LED Luminaire conformity to IS:10322/Part ... of LED Luminaire as ... each LED luminaire unit ... * LED Luminaire for ...
LED Luminaire (Recessed Luminaire) LED Luminaire (Recessed Luminaire) ( 10 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values STANDARDS Conformity to Indian Standard IS:10322/part ... type LED Luminaire /System ... each LED luminaire unit ... * LED Luminaire for ...
Inverter With Double Battery, laptop battery, laptop Adapter, LED Bulb, Extension Board, Computer All in One, Almirah, Table, Chair, SSD Internal 500 gb, Smart TV 55 inch, Keyboard BOQ Title BOQ BOQ
Bamboo Long 10 ft, Target Fig 11 Sheet Steel, Target Fig 11 Paper, Target Paper 1ft x 1ft Rif, Bulb 40 watt, Holder Bulb, Bulb Holder Shed, Wire Single Cord, LED Bulb charging
LED Luminaire (For Road and Street Lights) LED Luminaire (For Road And Street Lights) ( 60 ) Technical Specifications Specification Specification Name Values Allowed Values STANDARDS LED Luminaire conformity to IS:10322/Part 5/Section 3/2012 latest ... of LED Luminaire as ... each LED luminaire unit ... - LED Luminaire for ...
SPECIAL REPAIR FOR REPLACEMENT OF OLD FP/WP LIGHT FITTING INTO FP/WP LED FITTING AT TBRL RANGE RAMGARH UNDER GE I R AND D CHANDIGARH
STUDY TABLE, STEEL ALMIRAH, STUDY CHAIR WITH ARM, BED WITH MATTRESS AND PILLOW, 3 SEATER SOFA FOR VISITING ROOM, VISITOR CHAIRS, CEILING FANS, DINING TABLE WITH CHAIRS SET, LED BATTEN BOQ Title BOQ FOR HOSTEL FURNITURES RKM GIRIDIH
LED Luminaire (Recessed Luminaire) (V3) Conforming to IS 10322 (Part 5/Section 2) (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Experience Criteria, Bidder Turnover, Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 3, -- Number of days for which Bid would be auto -- extended 10 Bid Number : GEM/2025/B/6820345 Dated : 24-10-2025 Bid Document 1/6 Number of Auto Extension count 1 Bid to RA enabled No RCM Applicable Yes Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 3 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No
LED Luminaire for Floodlight (V2) Conforming to IS 10322 (Part 5/Section 5) (Q3) MSE Exemption for Years Of Experience Yes | Complete Startup Exemption for Years Of Experience Yes | Complete Document required from seller Certificate (Requested in ... category LED Luminaire for ...