Providing and fixing of suitable size cable end box of both HT and LT sides transformer of different ratings installed at D.D mines substation and gandhi nagar substation with suitable cable glands to avoid any ingress of dust and water in respect of
Complete repairing and rewinding of 30KVA Transformer 6.6KV by 220V phase to phase with mid point earthed and not exceeding 250V 3 phase polish make Sl. No 621800 oil cooled type for surface and in quarry of the mine under ASP Colliery.
complete repairing and overhauling of 1 no HT switch 3.3 KV 400A Mine line make VCB switch sl no 910 for controlling of 3.3kv secondary side of 2000 KVA transformer at 9 no siding of Amal.NT-ST-JG OCP under Lodna Area.
Erection of 30 nos, 11 Mtr Steel tubular Pole with 6-wire 440V, overhead line through AAA rabbit conductor for chamatu coal patch weighbridge for providing power from 11 KV, 440V Transformer to be installed by JBVNL under magadh OCP, Magadh-Amrapali
Complete Repairing and Overhauling of 1 No HT switch 11KV 400A Crompton greaves make OCB switch for controlling of 11KV primary side of 2MVA transformer sl no.ST/SW/OCB/11KV/27 at 9 no siding of Amal.NT-ST-JG OCP Under Lodna Area.
Providing and installation of Aerial Bunches cable for renovation of overhead line with 19 Nos. pole painting of Rusted old poles and 4 nos. stay set from G.M.Office transformer room to Executive Hostel, SBI Bank and Foot Ball Ground road street ligh
Complete Repairing and Overhauling (A) 3.3 KV 400 Amps Make Southern Gear OCB Switch with Busbarat 7 Pit Jealgora Old Sub-Station for Main Controlling of Lighting Transformer Local Id No. JL/SW/29 and Sl.No. 682/870 ( B) Complete Repairing and Overha
(A) Erection of lighting OH line due to advancement of mine working area at the north east part of the mine (B) Erection and extension of HT OH line for providing source power to the lighting transformer to be installed..... Ashok OCP
Rep. of two VCBs, 6.6kV, 1250A, Sl.No. 6281, Make Meditron and 11kV, 800A, Sl. No.8637, Make Andrew Yule both outdoor type engaged as primary and secondary switchgear of 3MVA (11kV/6.6kV) Transformer at QNo. 01 SS under PND OCP, NK Area
Partial Repairing Stude Gasket and Cooling tube cleaning of 300 KVA 2.2 KV/440V 3 Phase Marson Electric Make Lighting Transformer at Jealgora 7 Pit Old Sub-Station Sl.No. 12537 Colliery Id No. JL/TR/300 KVA/11 of Amal.Joyrampur Colliery under Lodna
Complete Rewinding/ Repairing of One(01) No.250 KVA 3.3KV/440 Volt Lighting Transformer GEC Make Sl.No.SQ61/1116 and Local Id.No. NT/250 KVA/TR/09 for Lighting Line of Sector-II MOCP Colony of Amal.NT-ST-JG-JG Colliery under Lodna Area.
Repair of one no. 550V, OCB switch, 600 Amps, make-Brush Electrical Eng. Co. Ltd., SI. No.45/85473/12 installed at 9.0 colony substation for Secondory controlling of 300KVA, 3.3KV/550V Transformer used for pumping etc. and installation of 01-no. MCCB
Diversion, Erection, Dismantling of 6.6KV D/L feeder clear the area out sourcing patch old point power supply JOCP patch 4000 GPM pump and installation of 10KVA/6.6KV/220V, Transformer for lighting purpose (B) Diversion of 220V LT O/H line clear the
Dismantling of 500KVA and 250KVA Transformer of 35 no. incline and installation of the same at WTP and 35 incline respectively with complete cable removal and jointing work at the same place for smooth water supply for 1000 GPM pump at WPT.
Dismantling and Re-Erection of (A) Overhead Line 550 Volt from Budhi Bandh to 1 No.Chhat Talab to Officer Bunglow (B) Overhead Line ( 2.2 KV) to 1 No. Bararee old transformer Room about 450 Mtrs length under Bararee Section of Amal.Joyrampur Co
Diversion/Modification/ extension of 3.3KV O/H line for providing power at new location of pumping station and Extension of 440V O/H line and shifting of 100KVA, 3.3KV/440V Transformer for lighting near mines proposed site at Rajhara Colliery under R
Repairing of 11KV 400amps A Yule make VCB switch Sl No 3850 for controlling of 750KVA transformer 550volts at Madhuban new pit sub station and repairing of 800amps Erskine heap make 550volt Sl No 327461 for controlling of KKC link feeder breaker and
A. Repairing of 400Amps welding transformer Air Cooling make 550V./500V/440V/220V Colliery Sl. No. Phu/Welding Tans/03 controlling of KKC Link of Feeder Breaker. 550V/500V/440V/400V/220V, Colliery Sl. No. Phu/welding Trans/03 controlling of KKC link
10 Nos. Bharat Bijlee Siemens Make Transformer Oil Filtration, Testing, Silica gel Changing and Total Body (Out Side) Conservator Tank Cleaning, 06 Nos. - 1750 KVA, 02 Nos. 1250 KVA and 02 Nos. 500 KVA. Rating 6.6 KV/ 415 - V at Sudamdih Coal Washery
Renovation of O/H line with providing of PCC poles, aerial bunch cable, junction box etc. for provision of 3.3KV/440Volt O/H line through 10KVA transformer A.B Cable from near of CPP gate switchyard to In-motion Weigh Bridge under Kathara Washery
Maintenance of 3.3 KV OHL from Coal Stock No. 01 to end point or Purnadih Basti for uninterrupted power supply to HT pump (3.3 KV), 100 KVA Transformer and mines (extended patch) at quarry no. 01 mines under Purnadih Project, NK Area
Complete Repairing/Overhauling and Safety Protection of 400 Amps 2200 Volt Southern Switch Gear Make O.C.B.Switch at 1 No. Bararee as a Main Power Controlling of Lighting Transformer of Bararee Colliery Sl. No. BAR/TRANS/19 Local Id. No. BAR/SW/19.
A)Changing of corksheet and brass stud and other elect.Work in 2MVA,11KV/6.6KV transformer Sl.No.Mur/08 A/Yule make to feeding power of Jarlahi face pump in SOCP,(B) repairing of electrical wiring of NHS Q.No.390 of Muraidih Colony, AMP Colliery
Complete Repairing of (A) Rewinding of Transformer 550/440 Volt 65 KVA Local ID.No. NS/TR/03 and (B) Complete Rewinding /Overhauling 550 Volts 400 Amps ACB Type Mine Line Make Switch Local Id. No. 100 FLP of N.S. Workshop under Lodna Area.
A. Rearrangement in 440 V LT OH line of Excavation workshop , installation of 11 KV grade GOAB and installation of 10 KVA Transformer near outsourcing coal stock yard at Tapin North OCP under Hazaribagh Area. B. Repair maintenance of 440 V OH line
Repairing of VCB and its control panel of 3.3kV, 1250A, VCB Andrew Yule make, Sl. No. 3126 Secondary Main Control of 7.5 MVA Transformer with remote control panel installed at 33/11-3.3kV, 22.5 MVA Old Substation of KDH OCP, NK Area
Carriage of spillaged coal from the floors and shed of PS-3 transformer room and west side of PS-3 floor and building shed by manual labour including loading unloading and stacking and loading of stacked material to belt / chute / suitable place for
Complete Repairing /Overhauling of 01(One) No. 200 H.P. AMBA Make Auto Transformer Starter of Submersible Pump Sl. No. A-316-45 Types ATS 550 Volt 3 Phase 50 HZ/AC of 1 Pit Lodna Section of Amal.Joyrampur Colliery under Lodna Area.
Day to day cleaning of grass and bush inside the boundary and its nearby its approaching of 33/11KV main sub-station and around the transformer installed in colonies like barwabera village, phase 2, KMP colony, konar siding, and 750 KVA crusher trans
Repairing of 500KVA/11KV/440V lighting transformer sl no. 5G/15 at Aambagan 15 no. Domagada Sub-station South Govindpur Colliery Govindpur Area III. B. Minor repairing of 800 Amps. Main line make NFLP ACB switch 550V/440V, sl. no. 04 for controlling
Complete Repairing and overhauling of 01 No. H.T. Switch 11 KV 400 Amp.ECE Make OCB Switch (Sl.No KJ/10/ ) for Primary Controlling of 500 KVA 11 KV/440V Transformer Main Switch at 3 Pit Mohribandh Sub-Station at Kujama Colliery Under Lodna Area.
(1) REPAIRING and OVERHAULING OF 200A,550V,SL.NO.10962 KILBURN MAKE,GTC UNIT,AGKCC.(2) COMPLETE REPAIRING OF 400 AMPS OCB SWITCH MAKE BIECCO LAWRIE 6.6 KV SL.NO.116937 CONTROLLING FOR 300 KVA LIGHTING TRANSFORMER AT OLD AREA OFFICE SUB-STATION AKWM
Carriage of spillaged coal from the floors and shed of PS-3 transformer room and west side of PS-3 floor and building shed by manual labour including loading unloading and stacking and loading of stacked material to nearby belt / chute / suitable pla
fabrication, dismantling of base plate and making of pump body short piece for installation of 4000GPM Pump-2 Nos.1000GPM Pump and 2400 GPM Pump of OCP NPC(ii)fabrication of cover box of Transformer 500KVA for protection of 11KV incoming and outgoing
Providing and Fixing Air Break Switch, Drop Out Fuse in HT side and outdoor cable termination work in LT side with other accessories work of two nos. Transformer installed near pit office and Shivpur Railway Siding and provision of Earth Leakage Rela
Carriage of spillage coal from the floors and shed of PS-3 transformer room and west side of PS-3 floor and shed building by manual labour including loading, unloading and stacking and loading of stacked material to nearby belt/chute/suitable places
Partial rep. and rewinding of Transformer 3 MVA, 11kV/6.6-3.3kV, Make Andrew Yule, Sl. No. 522(P), Vector group Dyn11, Cooling Type ONAN installed at Q.No. 01 Sub-stn and testing of different parameters from NABL accredited lab under Purnadih OCP.
Round the clock comp. AMC of all E.I and Running and manning operation of L.T Panel, 02 nos 1500 KVA DG set and 02 nos 500 KVA Dgd set and 02 nos 2000KVA Transformer installed in Jharkhand High Court at Dhurwa, Ranchi
Construction of Drain in Tridandi Ashram from Pramod Singh House to Main Drain via Vipin Saw House, Near Transformer in Gali from Pradip Vishwakarma and Manoj Rawani House to Bada Drain, In Manaitand Near Pani Tanki from Sanjay Saw..in ward no. 31
Complete Repairing and Overhauling of 1 No. H.T. Switch 11 KV 400 Amps ECE Make OCB Switch for Controlling of 1000 KVA Transformer Main Switch at 5 Pit Sub-Station at Joyrampur Colliery of Amal. Joyrampur Colliery under Lodna Area.(Local Id.No.JOY-5-
Complete repairing and rewinding of 01 No. 100 KVA 11 KV/440 Volt Local Id- BCCL/NT/100 KVA/TR/04 Lighting transformer for uninterrupted power supply for pahari Sub-Station to new colony of Amal. NT-ST-JG Colliery under Lodna Area.
(1) ONE NO JYOTI MAKE 33 K.V MOCB,DISMANTLING AND OVERHAULING400 AMP MOCB AT KC-2 PIT REGIONAL SUB-STATION KATRAS AREA FOR OUT GOING MOLB OF TRANSFORMER NO.O2,SL.NO.491/85.(2) PREVENTIVE/PREDICATIVE OF 33KV SENDRA BANSJORA LINE FEEDER INCLUDING DISMA
(1) (A) PART REPAIRING OF 1000 KVA 6.6/3.3 KV MAKE COMPTON GREAVES SL.NO.349/8 VOLT AT KESHALPUR SUB-STATION OF AKWMC UNDER KATRAS AREA. (B) COMPLETE REPAIRING/REWINDING OF 63 KV/3.3 KV-440 VOLT LIGHTING TRANSFORMER KANTAPAHRI SUB-STATION AKWMC
Complete Repairing and Safety Protection of 1 No.H.T.Switch 3.3 KV 400 Amps Electrotecnica Make VCB Switch Sl. No.FCB-060 and Local Id.No. LC/SW/209 for Controlling of 250 KVA Lighting Line Transformer Main Switch at 1 Pit Sub-Station Lodna Colliery
Carriage of spillaged coal from floors and shed of PS-3 transformer room and west side of PS-3 floors shed building by manual labour including loading unloading and stacking and loading of stacked material to belt / chute / suitable place for a lead
Construction of PCC road from main road to Transformer, Shambhu Das Gali , Shambhu Das to Old PCC and Rameshwar Jha to Lalu Yadav , Rameshwar Jha to Bablu Manda and Shibu Singh to Dr R P Singh at Ganga Nagar in ward no. 35
Complete Repairing and Overhauling of 1 No.H.T.Switch 11 KV 400 Amps Biecco Make OCB Switch Id.No. JOY/5/SW/11 for Power Controlling of 500 KVA Transformer Main Switch at 5 Pit Sub-Station of Joyrampur Colliery of Amal. Joyrampur Colliery under L
Complete Repairing of 11 KV 400 Amps.OCB Switch with Busbar Make Southern Gear Controlling of 300 KVA/11KV/440 Transformer for Lighting Purpose and welding Machine at Avinash Transport Camp Local Id. No.BCCL/NT/SW/11KV/61 of Amal.NT-ST-JG O.C.P.
Carriage of spillaged coal from the floors and shed of PS-3 transformer room and west side of PS-3 floors shed building by manual labour including loading unloading and stacking and loading of stacked material to belt / chute / suitable place for a
Partial Repairing of 11 KV OCB Switch with Busbar ECE Make installed at 11 KV incomer Switch Controlling breaker for 100 KVA/11KV /440V Transformer at 6 No. Sub-Station and Local Id. No. BCCL/NT/Sw/11KV 37 of NT-ST OCP.