Loading…
Loading…
6,352 results • Best match
164/R and M of boundary wall at Transformer Repairing Workshop Chutia, Ranchi
Onsite repairing of 2 nos of 3.3 kV grade 400 Amps Circuit Breaker i) PnM No-62 for control of pump feeder at DD mines substation ii) PnM No 48 for primary control of 500KVA 3.3KV/440V transformer and 3 nos of secondary 440 Volt controlling ACB sw
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - COAL MINES; Electrical System or Installation, Supply and installation of current transformer CT Potential transformer PT other electrical items of Kirloskar make 66KV ..
Job for (1) making of Platform and Shed for installation of 1 No. 1 MVA, 6.6KV/3.3KV transformer near TSS 4205 for feeding power to 3.3 KV OHTL of Bijan Village (2) Dismantling of idle 4 span 6.6 KV overhead power line Idle 4 pole of same line nea
PART REPAIRING AND FILTERATION OF (A) 750 KVA 6.6/550 VOLT LIGHTING TRANSFORMER SL.NO.96097 MAKE PARKINSON (B)500 KVA 3300/550 VOLT (c) 500 KVA 3300V/440 V GEC MAKE SL.NO.224237/1 (D)1000 KVA 6.6 KV/3.3 KV SL.NO.34918 V AT KESHALPUR COLLIERY SUB-S
Onsite Repairing of 5 Nos of 11kV grade 400 amps Circuit Breaker (A) Reyroll Burn make 11 kV 400 amps Sl no 87/153 for Secondary Control of 10 MVA transformer akkocp feeder (B) Reyroll burn make 11 kV 400 amps Sl no 87/117 for control of office
Complete Repairing of 400 Amps. 3.3 KV VCB Switch Make Prabhu CTR 50/5 SL. No. 123 Primary Controlling Switch of 100 KVA Transformer 3.3 KV/440 Volts Main Controlling Switch Local Id. No. BCCL/NT/SW/3.3/61 at Sector-2 Sub-Station of NT-ST O.C.P.
A) Complete repairing and Rewinding of 50 KVA 550 Volt/440 Volt 3 Phase Lighting transformer Local Id-BCCL/NT/50 KVA/550 V/440 V/TR-8 installed at Huchuktand sub station near 09 no. siding for power supply to Tisra colony. B) Partial repairing of 25
Overhauling of 220/132 kV, 100 MVA auto Transformer No. 02 make- kanohar, bearing Sl. No. KT-100000/1 cooling fans and overhauling of 33/0.415 kV, 315 kVA SST make Associated Electricals, bearing Sl. No. AE/315 kV A/6 at 220/132 kV GSS Chandil-I
Work of erection of poles for fixing of GO switch and MCCB for the primary and secondary control of transformer AND replacement of damaged pole in LT OH near WB area, heightening of Fd No 1 (HT OH) near Pit Office and dismantling and fixing of 1 POLE
(A) Erection of 6.6 KV D/L feeder power supply EKG-496 Installation of 6.6 KV/220V Transformer for lighting haul road and face JOCP patch, Dismantling of 6.6 KV D/L feeder clear the area out sourcing patch (B) Dismantling and Erection of 220V LT O/H
(A). Repairing of 3.3KV, 630A, VCB, CTR 600/300/5A, make-PCE, Sl.No.-05/HMV/132 installed at main sub-station of GVP Phase-II OCP, (B). Repairing of 3.3KV VCB, make-PCE, 630A, Sl.No.-05/HMV/131 of secondary switch at 3MVA, 11KV/3.3KV transformer of G
Supply and Installation Of 5 nos, of JVS make Earth leakage relay in Bicco Make, 400A, 3.3 KV Main Controlling Transformer 1) Sl no. 4277. 2) SL No. 4276 3) Sl no.4272 , 4) Sl no. 4275, 5) Sl no. 493 of 5/6 pit colliery at site
(A)Transformer Oil Filtration and Repairing of 750KVA,11KV/550V Sl. No.S854-1 BenidihU/G and 750KVA,11KV/550V transformerSl.No.S854-2 at FB Siding S/S (B)Repairing of GEC make,440V,1200A OCB switch,type K-5,Sl.No.50/0241 of KKC link F/B S/S,AMPC.
Make base to install 11KV outdoor type VCB control of 3MVA, 11 KV or3.3 KV P transformer,3.3KV outdoor type VCB as control of 3.3KV power of F- 1,cable lying, connection work ,S/F g. bush,clamp in control switch gear at 4 MVA 11KV/3.3 main Substation
Complete Repairing and Overhauling of One No. Submersible Auto Starter 175 HP 550 Volt Amba Speed Make 3 Phase and Rewinding of Auto Transformer Sl. No.249 at 7 Pit Sub-Station Local ID No.JL/STR/02 Serial no-AS/249/210-11 at Jealgora Colliery of Ama
(A) Lifting and lowering of 02 Nos. submersible pump with 6 inch dia 14 Nos pipes at K.T. Pump (B)Cutting old and used iron materials from old Transformer shed structure at KT substation for making a new shed at Paharigora (Size 17 ft Long X 15 ft wi
Complete Rewinding of 02 Nos. 10 KV Lighting Transformer 3.3 KV/220 Volts Installation by CKE-142 Balram Machine and Houl Road Lighting Line purpose Sl.No.(1) EST- 23787 and (2) 2378 of Amal . NT-ST-JG OCP under Lodna Area Local Id No. BCCL/NT/10 KV
Repairing of 5 nos of 33kV grade Sf-6 Control (A) ABB make control panel Sl No-OHB 1469 for primary control of 33kv/3.3 kv 3.15MVA transformer . (B) ABB make 33 kv grade control panel sl no - IVY030315000203 for ontrol of 33kv /11 kv 3 mva M
Cutting old and used iron material from near 9 No. Siding Structure and Making a new shed for transformer and One No. 3.3 KV Switch has to be installed for power supply of F Patch Jeenagora at near KT Sub-Station under Amal. NT-ST-Jeenagora Project u
Partial Repairing and Safety Protection of 01 No HT Switch 400 Amps Make Crompton Greaves OCB Switch for Controlling of 11 KV Primary Side of 1000 KVA Transformer Sl. No. Dum/SB/SW/27 at 9 no. Siding of Amal. NT-ST-JG Colliery under Lodna Area Id. No
Onsite repair and maintenance of two nos. of VCB Switches, first 3.3 kV, 1250 A, Andrew Yule make, Sr. No. 2545, second, 3.3 kV, 800 A, Andrew Yule make, Sr. No. 0017, and its connection with the transformer and one no. of OCB Switch, 3.3 kV, 400 A,
Complete Repairing /Overhauling and Safety Protection of 400 Amp.11 KV Meditron Make VCB Switch Sl. No.6363 Local Id BCCL/JG/SW/11KV/12 for Power Controlling of 500 KVA 11KV/550 Volt and 250 KVA 11 KV/440 Volt Transformer at KT Sub-Station of Jeenago
Dismantling, Erection, Breakdown an Repairing of 6.6 KV HT O/H line advancing of face power supply 4000 GPM Pump, shovel M/C Drill M/C 9 seem and DECO Patch of ABOCP and installation of 10 KVA/ 220 V Transformer for lighting coal face and DECO Patch
For Repairing of 02 nos. of 400Amp 11KV grade OCB BIECCO make and 400A 11KV grade OCB Crompton make acts as controlling of 02 nos of 1000KVA 11/KV/440V Transformer at NPTS(ii)(a)and 400Amp 11KV grade VCB Andrew Yule make act as main controlling Swit
Dismantling of 2 nos poles and 4 Span conductor along with erection of 3.3 KV oh line of poles with 5 span conductor near pahari rise side of VOCP (II) Eretion of 2 nos of poles aong with installation of lighting transformer 10 KVA 3.3 kv/220 V for
Onsite repair and maintenance of two nos. of VCB Switches, first 3.3 kV, 800 A, Andrew Yule make, Sr. No. 0017, second, 3.3 kV, 1250 A, Andrew Yule make, Sr. No. 2545, and its connection with the transformer and one no. of OCB Switch, 3.3 kV, 400 A,
Custom Bid for Services - Necessary Dismantling Transportation from DSTPS Andal WB to KTPS JH Erection Testing Commissioning of one no of 315 MVA Ms BHEL make 400 220 KV Inter connecting Transformer ICT along with other associated works at KTPS of DV.. Similar Category Repair and Overhauling Service
Custom Bid for Services - Day to day electrical maintenance of OH line 3point 3 kV and 415 V breakdown job external street lighting maintenance job minor maintenance of transformer and switch in public utility building along with power supply job d.. Similar Category Manpower Outsourcing Services - Minimum wage
Repairing and maintenance of 2 nos. 440V LT control panels for secondary control of transformers installed at different places of SDOCM, Dhori Area.
Supplying and fitting of copper cable lugs 185sqmm and 240sqmm of different transformers and power controlling switches at regional substation under Kathara Colliery
For Installation 2 inch GI pipeline from 3.15MVA 6.6KV/11KV and 7.5MVA 6.6KV/11KV Transformers to oil soak pit at SBRS Sijua Area
Minor repairing and preventive maintenance of 01 no 250 KVA,11KV/440 V transformer
Providing and installation of DTH, 400Amps for 500KVA, 3.3KV/440V Transformer under Bhurkunda Colliery.
Repair and maintenance of floor and gate of transformer repair workshop at Karandih, Jamshedpur.
Installation/Commissioning WTI/OTI meter with Buchholz relay alarm tripping circuit 03 nos transformer 1 no. 1000 KVA 6.6 KV/415V and 2 nos 900 KVA 6.6 KV/380V a. 3302A/2 , b. RY 3302/1 c. RY-3308/02 VOLTAS make at site of P.B Project Colliery
supply and commissioning and installation ofdigital x-ray 300ma with cr system (Q3), supply and commissioning and installation of isolation transformer servo 10kva (Q3), supply and commissioning and installation of isolation transformer servo 20kva (Q3)
Repairing of following equipment as mentioned below 1.rewind of 3.3KV/220V lighting transfrmer 10KVA of departmental 2.Complete rewind of lighting transformer 550V/220V 3.Complete rewinding of 1.5KVA,550V/125V drill panel transformer
Online UPS Online UPS ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM without inbuilt isolation transformer IGBT-PWM without inbuilt isolation ... isolation transformer Input ...
A) Dismantling of 6.6 KV SF No-1 6.6 D/L feeder 6.6 KV benidih feeder and dismantling of 10 KVA/6.6 KV/220V Transformer for advancing of face power supply shovel M/C, drill M/C, D/L M/C 4000 GPM pump ABOCP Mine B) Diversion, Dismantling and Erection
Repairing of one no 11kv/ 400 Amp long and coford make OCB, P and M no 9 used at primary side of 3 MVA, 11KV/ 3.3 KV transformer and (b) 11KV, 400Amps reyroll burn make OCB Si NO 87/63 for control of crusher feeder at main substation under AKKOCP
Complete Repairing of 3.3 KV 400 Amps GEC Make CTR 200/5 Ampair OCB Switch Controlling by Lighting Line Colony Transformer Sl. No. OCB/M-163 local Id No. BCCL/NT /SW/3.3 KV/ 05 of 6 No. Sub - Station of NT-ST O.C.P. Local Id.No. BCCL/NT/ SW/3.3KV/05.
Complete Repairing and Overhauling of (A) GEC Make 11 KV/400Amps Local Id. JL/AW/16 and (B) 1000 Amps ACB Switch 440 Volt Transformer Local Id. JL/ACB/SW/415V/47 (C) Auto Starter Amba Make Local Id. No. JL/ ST/06 Installed at 2 Pit Sub-Station Jealg
(A)Complete Repairing and Overhauling of One(01) No. HT Switch 11 KV 400Amps 11 KV Primary Side of 3150 KVA Transformer Sl.No.ST/SW/OCB/11KV/27(B)VCB Switch Sl.No. 910 (C)O.C.B. Switch with Busbar ID.No. BCCL/NT/SW/OCB/49 and Sl. No. 30/0089 at 6 No
Complete Repairing and Overhauling of 1 No H.T Switch 11 KV 400 Amps ECE Make OCB Switch for Controlling of 200 KVA Transformer Main Switch at 5 Pit Sub-station under Joyrampur Colliery Sl. No JOY-5-sw-6 Model NO JOY 5/SW/OCB/11KV/06 of AJC Under Lod
Set of Hotel load bushing gaskets (Location A, B, C, D, E) for 7775 KVA 3 Phase loco transformer., bushing type DIN DT 3/1000 as per Annexure attached. A Set consists of 05 items in 20 Nos. Material should be supplied as per TC No- ELRS/TC/0076 Rev-1.
Providing of Platform for 250 KVA (3.3 KV/440V) Transformer Installed at Jholandia Basti and also making an arrangement of barbed wire fencing around the transformer for safety of nearby lives under Purnadih Project, N.K. Area
Repair and maint. Of 11KV OH line from SDOCM S Sub-station to CHP transformer point river side 1 MVA Transformer, Kalyani officer colony and Turio colony and CISF barrack A-company, Karipani in SDOCM S.
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - COAL MINES; a Complete repairing of no name plate 315KVA 66KV440V transformer lying at electrical repair shop b repairing of powerwaere make 160 KVA 66KV440V transformer..
Construction of PCC road from Makro Pahad to electric transformer in Village- Makro G.P. - Karmatad