Loading…
Loading…
2,360 results • Best match
Replacement of sewerage pipe line dia 150mm damaged with new pipe line of 200mm dia for laying at MD Khan Cloth merchants to 19-3-262/60 at Vattepalli under M.R.G Section 2) Laying of 200mm dia SWG sewer line at 19-3-528/3/D to RR Residence, IPS ... Electrical Transformer (Opp: ...
laying of water supply pipeline from Housing Board Office to H. No. 1-1-1/A/100, from 1-1-1/A/72 to Govt. Primary School, from E.P. No. 1/9 to 1-1-1/A/50/1, from EP No. 1/30 to 1-1-1/A/142 in ward No. 1 and from Naini Krishna house to Transformer in R.B. Nagar, Ward No. 6 , Municipality under General Fund.
Rock cutting & laying of UGD from P.No.62 to Transformer No.200224737, from P.No.5 to 21-695/10/7, from H.No.21-639/9/ to 21-695/7/3, from V.B Polymer to EP No.128/2/9/4, from EP No.128/1349 to EP No.128/1347 in Shivalaya Nagar of Suraram in Ward No.129, Gajularamaram Circle, GHMC (Item No.9) (Completion period: 3 month)
Remodeling of 100mm dia RCC water supply line with 100mm dia DI W/S line due to pollution from H.No.18-10-380/6 to Boardan Bowli Nala Transformer and from Masjid-E-Mehdi to H.No.18-10-40/20/A to Doodh Ki Doodi to H.No.18-10-214/5 at Barkas area, Chandrayangutta ward under Maisarm section, Sub Division-I of Operations and Maintenance Division-II(B)
Laying of CC Road H.No:7-45/1 to H.No:7-176 (Toor Colony), H.No:7-45/1 to H.No:91/9, H.No:7-142/2/1/A/1 to H.No:7-171/14/2 (Toor Colony), H.No:7-31/1 (Ghora Aunty) to Yousuf Kirana store (Toor Colony) & Transformer to H.No:7-53/4 (Sadath nagar) at Toor colony & Sadath nagar Ward No.27 in Jalpally Municipality under HMDA Grants.
Laying CC road and SWD drain at 19-2-238/4/1 to transformer nos 200179097, 230/6/C/3 to 239/25/F/2/2, 238/2/A/1/2 to 238/6/F/A to 238/3 and 238/6/F/A to 227/B via 227/2/F/3 in Rahmathpura in Ramnaspura Div-55,W-19,CRZ,GHMC. (Reserved for Individual ST Contractors proprietor firms / Partnership firms )
Laying of CC raod by RMC from 19-5-44/A/1/A via 19-5-44/A/16/A/1 to Transformer at Asadbaba nagar from 19-5-44/A/24/M to Ttransformer via Yousafain Ice Cfeam , 19-5-44/A/P Syed Darya Islamic Center, from 19-5-32/22 to Akber darbar Hotel at Asadbaba Nagar at in Kisanbagh divn . (RESERVED FOR ALL WLCCS)
High Voltage HRC Cylindrical Fuse 2 Amps (without holder), 1.2KV, Size: 8X50MM for Voltage Control as per Item No. F01 to F06 and Place of Installation S1F90 to S1F96 of Bill of Material of RDSO Spec No. RDSO/PE/SPEC/AC/0184-2015. (Rev-0) Used in ... Control Transformer LHB ...
25 Amps, 500 Volt AC, NH Knife Blade Fuse (Din Type), size NH000 with caharacteristic:-gG/gL, breaking capacity 120 KA. confirming to IS: 13703/IEC 60269-2, suitable for KVA Transformer 415 output side HRC fuses in underslung HV power panel. Accepted Makes: Siba/EFEN/Ferraz/ETI/Siemens/Bussmann/Schneider/GE/L&T Only as per item No. 7,8,9 of BOM in Annexure-A of EDTS 355 EDTS, Rev-1.
Attending to break down calls, replacement of switch in panel, feeder pillar box near transformer and other connected works in Asman Mahal Staff quarters, Hyderabad
Custom Bid for Services - Repair of 1600KVA, 11KV/433V Voltamp Transformer at Astra Service Block Similar Category Operation and Maintenance Of Electrical Systems/Electrical Installations
FUSE AND FUSE LINKS, ELECTRONIC MODULE or PCB or CARD, SCR OF EACH TYPE AND RATING, BLOCKING DIODE OF EACH TYPE AND RATING, AUX TRANSFORMER
Annual Maintenance Estimate for Dam and Appurtenant works, Generator and Transformer of Kaddam Narayana Reddy Project Kaddam (VandM), Nirmal (Dist) for the year 2026-27.
REPAIRS MAINTENTANCE OF HT DISTRIBUTION SYSTEM INCLUDING REPAIRS TO TRANSFORMERS, GODS, LAS EARTHING AND ALLIED WORKS AT AOC CENTRE, MUDORT, HANUMAN TEMPLE, HAVLOCK LINE, NCC, 54 DOU, SAFILGUDA, SHAPERS LINE, ABC LINE, SOLAR PLANT AND ADJOINING AREA
(3rd Call) Emergency Repairs to 500KVA (11KV/433V) Transformers of Mangela Lift Irrigation Scheme on Right bank of Godavari River at Mangela (V), Beerpur (M), Jagtial (District) (Invited under earmarked works- SC communities are only eligible to participate)
Supply, Installation, Testing and Commissioning of 11kV, 630kVA Compact Sub-Station (CSS) with CRT DRY Type Transformer for TiHAN complex expansion, IIT Hyderabad campus, Kandi, Sangareddy.
Emergent Repairs to 500 KVA (11 KV/433 V) Transformer at Jaina Lift Irrigation Scheme on Right Bank of Godavari River in Dharmapuri (M), Jagtial District
Emergent Repairs to 315 KVA (11KV/433V) Transformer of Kammunoor Lift Irrigation Scheme on Right bank of Godavari River at Kammunoor (V), Beerpur (M), Jagtial Dist
Digital Multimeter-IS:9000, Insulation Tester-IS 9000, true rms clamp meter, Digital Earth Resistance Meter-IS 9000, Contact Resistance meters, Transformer Oil BDV Test Set
Supply of Numerical Non - Directional Microprocessor based 3O/C+ 1E/F Protection Relay of operating, Supply of Numerical Draw out type Transformer Differential & Protection Microprocessor based Relays
Laying of CC road near transformer at Sri Sai Enclave to clear water stagnation, Dammaiguda Ward No.04, Keesara Cir-01 Malkajgiri Zone, MMC(item no.3)
Construction of CC Drain from 2-94/12 to 3-8, and E.P.No. ASN 8/2 to 3-69/E2 and house of yamanna 3-68/3, and 3-69/2 to 6-17 and 5-87 to 5-74/1 via 5-94 and 6-37/1 to 3-69/4 and house of bellal to laxmipriyanagar common armoor road and 3-66/63/4 to ... existing transformer in
Supply, delivery and fixing of 1600 Amps ACB, with outdoor panel having outgoing 400 Amps MCCB and 250 Amps MCCB 4 Pole of Two nos each with suitable water proof busbar along with digital indicators to the 500 KVA transformer for the incoming power supply to the Banjara Hills Pump Houses including control wiring with suitable lugs including GST at Banjara Hills Substation under Electrical and Mechanical Section, EAMC-V, O and M Division No.VI
Laying of C.C Road in internal lanes at Jk colony Plot No 01 to transformer and Pochamma Temple surroundings & Reddy colony from plot no 133 & 129 to plot no 84 to plot no 83 and plot no 61 to plot no 54i& bhagya nagar colony from 1-9-323/26a to 1-9-323/15 n Ward No.3 Cherlapally of Kapra Circle, GHMC (Reserved for Individual ST Contractors / Proprietorship Firms / Partnership Firms / ST LCCS).
Construction of Shed at Gangaram Solid waste management park, Water Supply arrangements - Borewells with submersible motors and internal pipelines, Power - Supply and arranging of Transformer with electrical poles and three phase conductor, Construction of Waste receiving platforms , Construction of Compost windrow platforms, Construction and arranging of Compost screening, refinement and storage shed, Construction of Office and security room, Construction of Vehicle wash cum garage facility under 14th FC Grants For the year 2018-19
(i) Laying of CC Road from Main Road to Vegetable Market (also internal lanes) in Vijayanagar colony in Div. No. 63 (ii) Laying of CC Road, Construction of CC drain from Main Road Masjid to Transformer, Vishnupuri via Hanuman Temple in Div. No. 63 (iii) Construction of CC drain and culvert and Laying of CC Road from HDFC ATM to Muslim Graveyard Waddera Colony near St. Anns School in Div. No. 63 (MGF)
HRC Cylindrical Fuse 2 Amps (without Holder), 500V, 120KA, Size: 10x38mm conforming to IS:13703/IEC/EN-60269-1&2 used in secondary circuit of 100VA Control Transformer LHB type AC & Non AC Coaches as per Item No. 5 and Place of Installation S1F151 to S1F156 from the Bill of Material of RDSO Spec No. RDSO/PE/SPEC/AC/0184-2015. (Rev-1) . Accepted Makes: Eaton, Siba, Bussmann, ETI, L&T, Siemens, ABB only.
REPAIRS / MAINTENANCE OF HT DISTRIBUTION SYSTEM INCLUDING REPAIRS/REWINDING TO TRANSFORMERS GODS LA S EARTHINGS AND ALLIED WORKS ATCDA DAD PAO(AOC) MH MEADOW LINE MH AREA GOLDEN PALM STN WORKSHOP AND ADJOINING AREA AND ALLIED WORKS AT DGQA U
REPAIRS MAINTENANCE OF HT DISTRIBUTION SYSTEM INCLUDING REPAIRS REWINDING TO TRANSFORMERS, GODS, LAS EARTHINGS AND ALLIED WORKS AT DIV UNITS AREA ,54 IDSR,554 ASC BN,654 EME BN , 729,289,ASSAY LINE,SAFILGUDA PKT 2, AND MEDOWS LINE, MAP JCOOR
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - 11 KV 433 V Electrical SubStation and overhauling the transformer and related to associated works; Substation; Service Provider
Maintenance of centralised AC system of MCR, Packaged AC untis of chem.lab AHP control Room,Air Washer units AHUS and deluge system in transformer yards(2Y)at CPPHWPM
Approach road formation and supply, erection and removing of 600/400mm MS pipelines for running of 20Nos x 125/100HP submersible centrifugal pump sets strengthening of all 50 spans of PSCC 6.6KV, HT Electrical poles, servicing of 3Nosx 1250KVA, ... 11KV/433V transformers engaging ...
Contactor K-44 for 60 KVA Transformer, Rated current: 95 Amps, Rated Voltage: 690V AC, Main Pole: 4, Aux Contact 1 NO + 1 NC, Control Voltage: 230V AC (168-300V AC means 230V +/- 30%) with surge suppressor as per RDSO Specification No. RDSO/PE/SPEC/AC/0184-2015 (Rev-1) and as per updated BOM items issued by RDSO Lr.no EL/7.1.108/MSSBC, dated 19.09.2021 to ABB model no: AF 116 B-40, Schneider model no.LC1D1150046M5 + LA4DA2U only accepted.
Laying of Under Ground Storm Water Drainage Pipeline from #5-5/27/42 to #5-5/27/18/S, Plot No.52 ( Biksham Goud) to #5-5/27/177/SP, #5-5/27/172 to #5-5/27/177/SP, Transformer to #5-70/111/1523, Plot No.96 to #5-70/111/1523 & #5-70/126/A/1 to #5-70/111/1523 in Laxma Reddy Colony of Division No.15 of Boduppal Municipal Corporation under general funds
16 Amps, 500 Volt AC, NH Knife Blade Fuse (Din Type), size NH000 with characteristic:-gG/gL, breaking capacity 120 KA. confirming to IS: 13703/IEC 60269-2, suitable for 9KVA Transformer 415V output side HRC fuses in underslung HV power panel as per EDTS 355 EDTS, Rev-1. Accepted Makes: Siemens / WOHNER / ITALWEBER / Ferraz / Bussmann / Schneider / GE / L&T Only as per item No. 12,13,14 of BOM in Annexure-A of EDTS 355 EDTS, Rev-1.
MCB for 5KVA Transformer (primary) 16A, D Curve, 415 V AC, 3 pole, breaking capacity 10KA. Suitable for LHB type AC Coaches. As per Sr. No. 32 and place of installation S1F107 of RDSO letter no. EL/7.1.108/MSSBC dated 17/09/2021. Material is catalogue no. 5SL73168RC of Siemens or S B203 M-D16 of ABB or BB30160D of L&T or FAZ-D16/3 of Eaton or A9N3P16D of Schneider or 408762 of Legrand only.
Transformer Oil BDV Test Kit (Q3) MSE Exemption for Years Of Experience and Turnover Yes | Complete Startup Exemption for Years Of Experience and Turnover Yes | Complete Document required from seller Certificate (Requested in ATC), OEM Authorization Certificate, Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6884858 Dated : 29-11-2025 Bid Document 1/9 Number of Auto Extension count 1 Bid to RA enabled Yes RA Qualification Rule H1-Highest Priced Bid Elimination Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Advisory Bank State Bank of India (%) ePBG Percentage(%) 5.00 ( ) Duration of ePBG required (Months). 3 (a)., EMD & Performance securityshould be in favour of Beneficiary, wherever it is applicable. Beneficiary : Regional Director P & S (On behalf of the President of India) Directorate of Purchase & Stores, Department of Atomic Energy, Nuclear Fuel Complex, HRPU, ECIL POST, HYDERABAD-500062 (Ref. No. HRPU/NFC/B2/1906) (Regional Director, P And S)
Custom Bid for Services - Retrofitting, Installation, Testing and Commissioning of 132 KV Transformer OLTC Control and OLTC Remote Control Panels Similar Category Operation and Maintenance Of Electrical Systems/Electrical Installations
REPAIRS MAINTENANCE OF HT DISTRIBUTION SYSTEM INCLUDING REPAIRS TO TRANSFORMERS, GODS, LAS EARTHING AND ALLIED WORKS AT MH, GOLDEN PALM, STN WORK SHOP, DGQA, DAD, CDA, PAO (OR) EME, PAO(OR) AOC AND ADJOINING AREA UNDER AGE E/M NO II OF GE(U) SECUNDE
Refurbishment and up-gradation of with new Control and Relay panels for Line feeder and 10/16 MVA Power Transformers feeders including erection and commissioning of the panels etc., complete at 132/6.6KV substation, Peddapur Campus under EAM Cell-II, Transmission Division No.II,Patancheru
REPAIRS MAINTENTANCE OF HT SWITCH GEAR INCLUDING REPAIRS TO TRANSFORMER, VCBS,GODS LAS EARTHING AND ALLIED WORKS AT MCEME AND ADJOINING AREA OF AGE EM NO II UNDER GE(U) SECUNDERABAD
Contactor K44 for 60 KVA Transformer, Rated current: 95 Amps, Rated Voltage: 690 V AC, Main pole: 4, Auxcontact: 1NO + 1NC Control voltage: 230 V AC (168 V AC 300 V AC means 230 V AC +/- 30%) with surgesuppressor as per RDSO Spec No. RDSO/PE/SPEC/ AC/0184-2015 (Rev - 1) and as per update of commonBOM items issued by RDSO Lr.No. EL/7.1.108/MSSBC, dt 17/09/21 to ABB Model No. AF 116B-40, SchneiderModel No. LC1D1150046M5 + LA4DA2U only accepted.
Laying of CC Road From Masjid-E-Ameena to Osman Nagar Lake & Construction of Storm Water Drain From Masjid-E-Ameena to Osman Nagar Lake & H.No; 12-115/28 to Transformer & H.No: 12-132/11 to Sajid House & H.No: 11-7 to H.No: 11-8/5/B & H.No: 11-4/2/5 to H.No:11-9/141 & H.No: 12-10 to Govt. School Venkatapur at Ward No.07, Osman Nagar & Al Ain Hills & Yahiya Abdullah Nagar in Jalpally Municipality under HMDA Grants
TGGENCO-YTPS(5X800MW)-SY TY-Tightening of clamps and connectors in 400kV switchyard from power transformers bushing, Bus Reactors and Repair and Alignment of Isolators and Earth Switches and Replacement of CT/CVT/CBs as and when required in YTPS plant during the FY 2026-27
Annual Maintenance for preventive and emergency maintenance to HT Electrical Installations at Electrical Sub Stations including all HT equipments like Transformers, Control Panels, LT Switchgear, APFC Panels, AMF Panels etc., and routine maintenance in the entire High Court premises for the period of one year 2026-2027.
laying of CC road from 8-15-130/9/a,transformer 200668512,8-15-130/1/p at diamond hills in ward no 58 in shastipuram division in Rajendranagar Circle 11 GHMC (Rs 25.85Lakhs)
Laying of CC Road & SWD Drain from Habeeb Colony (Bus stop) to Shah Hills, Bismillah Colony and Pasha Colony, Wadi-e-Saleheen ward office to Masjid -e-Rahmania, Quba Colony, Ahmed Shah Masjid to H.NO:7-62/1/A,H.NO-7-62/1/A BAD KI JAD welding shop to ... office, Transformer to ...
100A HRC fuse link (Low voltage fuse), DIN type, Rated Voltage 500V AC, Breaking Capacity- 100kA, Suitable for use in secondary side of 60kVA transformer & local main supply of LHB AC Coaches, Confirming to IS: 13703 Pt-2 & RDSO Specification No. RDSO/PE/SPEC/AC/ 0184-2015 (Rev.-1). Makes: Siemens, ABB, wohner, Bushmann, L&T, Italweber, Eaton as per item Sr. no. 8 & 34 of common BOM of RDSO letter no. EL/7.1.108/MSSBC dated 17.09.21 or any other make with prior approval of RDSO/RCF.
RC Filter Set consisting 01 Ohm, 6W Resistor connected in series with parallel connected 1.5 Micro Farad, 850V range capacitors of Epcos or Vishay make in each arm of Star connected to be provided between phase and neutral and phase and earth of each ... 60kVA transformer to ...
Laying of damaged CC road from Mallikarjuna swamy temple,Transformer, H.No:23-26/39/A to Mataji mini Kiranam, Famous Chicken center at Mallikarjun nagar in Ward No.23- Chilkangar, Uppal Circle-9, GHMC