Custom Bid for Services - SOR Line Item 00010 CAMC For APC Make UPS Including GST 18 Comprehensive Annual Maintenance Contract For UPS APC Make And Inverters Installed At SCOPE Complex And SMC GH New Delhi, Custom Bid for Services - SOR Line Item ... And Inverters Installed ...
ARMO of EI and fans, pump, sub-station, DG sets, UPS system, FF, FA, ETAC and WTAC system at GOI Press, Ring Road, Mayapuri, New Delhi. Subwork/Packages: Comprehensive maintenance of 150 LPH and 50 LPH RO system
Customized AMC/CMC for Pre-owned Products - INVERTER UPS WITH BATTERIES; LUMINOUS; Comprehensive Maintenance Contract (CMC); MONTHLY; No
Custom Bid for Services - AIAMC OF 64 Nos INVERTER 625VA 5500VA WITH 12V 120AH 135AH BATTERIES 131 N
SITC of inverter technology based Split type Air Conditioning units in various locations at North Block, New Delhi.
MOEI & fan at GOB s/DOB s bungalows under SD-III/DED-102, New Delhi.SH Maintenance of Inverter.
1.5 Ton Inverter AC/4500 Kcal/Hr Split AC 3 star rating.Make:- LLOYD/HITACHI/LG/VOLTAS/BLUE STAR
Customized AMC/CMC for Pre-owned Products - Automatic Transfer Switch (ATS) Panel (160A) for Riello UPS System; Havells; Comprehensive Maintenance Contract (CMC); Quarterly; No, Customized AMC/CMC for Pre-owned Products - Automatic Transfer Switch ... Riello UPS System ; ... Riello UPS System ; ... DELTA UPS System ; ... DELTA UPS System ; ... DELTA UPS System ; ... DELTA UPS System ; ... DELTA UPS System ; ...
Maintenance of various E and M services at Dr. KSSR Stadium Tughlakabad, New Delhi during 2024-25(SH: Replacement of outdated 15KVA-1No. UPS system at Trap No. 2 in Dr. KSSR stadium Tughlakabad,New Delhi-44) Subwork/Packages: Replacement of Outdated ... No. UPS system at ...
SH Comprehensive maintenance of Vinitec Make Online UPS and Servo Voltage Stabilizer
Line Intractive UPS with AVR, Online UPS Experience Criteria 2 Year (s)
Multifunction Machines MFM (Q2), Computer Printers (Q2), Online UPS (Version 2.0) (Q2)
All in One PC (Q2), Laptop - Notebook (Q2), Online UPS (V2) (Q2)
SH Comprehensive Maintenance of Vinitec Make Online UPS and Servo Voltage Stabilizer
SH Comprehensive Maintenance of Vinitec Make Online UPS and Servo Voltage Stabilizer
SH Comprehensive Maintenance of 200KVA 06 Nos online UPS and other services
SH Comprehensive Maintenance of 200KVA 06 Nos online UPS and other services
RMO of EI and Fans installed at New Block 1 and 2 Saket District Court Complex, New Delhi during the year 2023-2024. (Annual Comprehensive maintenance of fuji Electric make UPS system)
RMO CCTV Sub Sation DG Sets UPS System RO and compressed Air System at MAIDS New Delhi 2. MOEI Fans Fire Alarm System and Lift at B.L Taneja Block MAMC New Delhi
RMO E and M Services at Janak Puri Super Specialty Hospital C-2B Janak Puri, New Delhi (SH Comprehensive Maintenance of Vinitec Make UPS System, Servo Voltage Stabilizer and Step down transformer)
MOEI and Fans, Street Light and Pump Sets of 17 Nos. Dispensaries under Sub Division HSW-III (SH Comprehensive Maintenance of 10 KVA VINITEC make UPS System at Chirag Delhi Dispensary Delhi)
RMO specialized Electrical and Mechanical Services installed at Delhi High Court New Delhi. Sub Head Comprehensive Annual maintenance of 80 KVA capacity APC Make UPS system installed in C Block DHC ND
RMO UPS system Audio Visual Systems LAN system and Stage Lighting System at Delhi Sachivalaya, New Delhi. SH Attending Day to Day complaint and general maintenance of LAN and and Wi-fi
Maintenance and Operation of E&M services in PH Annexe, New Delhi. (SH: Providing Services for Operation of precision type Air Conditioners & UPS System for Sansad TV, Parliament House Complex, New Delhi).
RMO specialized Electrical and Mechanical Services installed at Delhi High Court, New Delhi. Sub Head Comprehensive Annual maintenance of 80 KVA capacity APC Make UPS system installed in C Block DHC ND.
ARMO of EI and Fans, Pump, Sub-Station, DG Sets, UPS System, Fire Fighting, Fire alarm, ETAC and WTAC System at GOI Press Ring Road, Mayapuri, New Delhi. (SH: Misc. Electrical Works )
Maintenance and Operation of E&M services in PH Annexe, New Delhi. (SH: Providing Services for Operation of precision type Air Conditioners & UPS system for Sansad TV, Parliament House Complex, New Delhi).
ARMO of EI and Fans, Pump Sub-Station, DG Sets, UPS System, Fire Fighting, fire Alarm, ETAC and WTAC system at GOI Press, Ring Road Mayapuri, New Delhi. (SH: Misc. Electrical Work )
MOEI and Fans at A, B, C, D, E, F, G, H, K, L, M, N Block Vikas Bhawan, New Delhi (SH. Comprehensive Annual Maintenance of 120 KVA UPS installed at Excise Department at L and N Block, Vikas Bhawan, New Delhi)
MOEI, Fans at A, B, C, D, E, F, G, H, K, L, M, N Block Vikas Bhawan, New Delhi (SH. Replacement of defective Batteries of 120 KVA UPS installed at Excise Department at L and N Block, Vikas Bhawan, New Delhi)
FCBC 48 Volt 50 Amps, Online UPS 2 KVA with inbult Batttteries, Online UPS 2 KVA, Online UPS 5 KVA with 16 x 12 volt 75 AHC btys and Rack, Online UPS 10 KVA with with 16 x 12 volt 75 AHC btys and Rack, Bty 12 Volt 42 AHC, Power Cable 2 Core, Change Over Switch 63 Amps, Change Over Switch 25 Amps, MCB 4 Pole, Digital Earth Test Meter
SITC of UPS at RBIPMT Hospital-Provision of 2 Nos. 60 KVA UPS in OTs and one no. 20 KVA UPS in SNICU at RBIPMT Hospital
UPS BATTERY, BATTERY UPS, DDR3 RAM, DDR4 RAM, PROCESSOR I3
Online UPS Online UPS ( 6 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA 2.0kva Technology MOSFET-PWM with inbuilt isolation transformer mosfet-pwmwithinbuilti solationtransformer Input Power single phase 160V - 260V sinewave, 50Hz singlephase160v-260vs inewave50hz Output power Single phase 230V +/-1% sinewave 50 Hz singlephase230v-1sine wave50hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 1900 Warranty for UPS (Years) 2 1, 2, 3, 4, 5 Movable trolly for Batteries Without With, Without, Without trollery but with rack Warranty for battery 1 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for synchronising With With, Without Installation and Commissioning Yes N/A 1/4 CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 N/A Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) N/A FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 N/A Voltage Regulation from no load to full load (%) /= 3% N/A 20% Overload limit for minimum 10 minutes Yes N/A Overall Efficiency (%) >/=90% N/A Total Harmonic Distortion(THD) (%) Maximum 3% N/A 50% Overload limit for minimum 1 minutes Yes N/A PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes N/A Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes N/A METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes N/A Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes N/A REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes N/A Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 Yes N/A 2/4 (reaffirmed 2007) at 55 degree C for 16 hrs Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes N/A Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes N/A Type Test Certificate No. R-410J5563 N/A Type Test Certificate date 08-11-20 17 N/A Name of Lab Bureau of Indian Standards N/A Address of Lab Manak Bhavan, 9 Bahadur shah Zafar Marg, New Delhi-110002 N/A As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anant Vaibhav 110010, Room NO 110 A, B bLock Hutments, Dara Shikoh Road 6 45 EMD Required No ePBG Required No
Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 10.0 KVA 10.0kva Technology IGBT-PWM with inbuilt isolation transformer igbt-pwmwithinbuiltisol ationtransformer Input Power single phase 160V - 260V sinewave, 50Hz singlephase160v-260vs inewave50hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 16000 Warranty for UPS (Years) 2 1, 2, 3, 4, 5 Movable trolly for Batteries With with Warranty for battery 2 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for Without With, Without 1/4 synchronising Installation and Commissioning Yes N/A CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 N/A Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) N/A FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 N/A Voltage Regulation from no load to full load (%) /= 3% N/A 20% Overload limit for minimum 10 minutes Yes N/A Overall Efficiency (%) >/=90% N/A Total Harmonic Distortion(THD) (%) Maximum 3% N/A 50% Overload limit for minimum 1 minutes Yes N/A PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes N/A Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes N/A METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes N/A Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes N/A REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes N/A 2/4 Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes N/A Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes N/A Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes N/A Type Test Certificate No. QML/M-18/2095 N/A Type Test Certificate date 13-03-2008 N/A Name of Lab GOVT. QUALITY MARKING CENTRE FOR ELECTRICAL GOODS N/A Address of Lab N.H – IV, I.T.I COMPLEX, FARIDABAD, HARYANA- 121001 N/A As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Moolchand Gujar 110066, Wst Block 3, R K Puram 1 15 EMD Required No ePBG Required No 3/4
SH Annual Comprehensive maintenance of 4 x 200 KVA UPS
SH Annual Comprehensive maintenance of 4 x 200 KVA UPS
Replacement of Inverter Type all weather 2 Tr Hi wall mounted split AC units at National Science Centre Delhi
MDL PWR 68817AX1AA - Inverter for Auxiliary Converter as per BHEL Part No. ED68817AX1AA. Make/Brand: - BHEL. Accepted Make : Self.
Sealed Maintenance free lead acid battery 300 AH capacity consisting of 52nos. (104 volts) of 2V cell module with inter cell and inter module connectors, hardware etc. assembled in stainless steel battery box complete to ICF Drg. No. SSA 7-1 001.(latest). Note:- All cells shall be interconnected using 50 sq.mm e- beam cable. Drg.No: ICF Drg. No.SSA 7-1 001.(latest) Sepc.No :The battery shall be generally confirming to RDSO Specification RDSO/PE/SPEC/AC/0009-2014 (Rev#02)
RMO UPS System Audio Visual System LAN System Stage lighting System at Delhi Sachivalaya New Delhi during 2020 21. (SH Comprehensive Maintenance of computers, Printers, Scanners at M253 Division and all Sub Divisions)
RMO Specialized Electrical and Mechanical services of Delhi High Court, New Delhi. (SH Comprehensive maintenance of 50 KVA on-line UPS system installed in New Server Room at 2nd floor of C Block)
RMO of EI and Fans installed at New Block 1 and 2 Saket District Court Complex, New Delhi during the year 2025-2026. (SH Annual Comprehensive maintenance of fuji Electric make UPS system)
RMO of Electrical and Mechanical Services, Pump Set, DG Set and Passenger Lift installed at College of Art, Tilak Marg, New Delhi (SH. Comprehensive Annual Maintenance of UPS System installed at Auditorium Block)
Operation and maintenance of sub-station equipments including DG sets, MOEI and fans, fire fighting, UPS system at INCP, South Block, New Delhi. SH : Refilling and servicing of various type of fire extinguishers.
Operation & maintenance of Sub-Station equipments i/c DG sets, MOEI & fans, Fire Fighting, UPS System at INCP, South Block, New Delhi. (SH: Comprehensive maintenance and Operation of CCTV and Access Control System.)
Operation and Maintenance of Sub-Station equipments i/c DG sets, MOEI and Fans, Automatic Map Display system, UPS system at INCP, South Block, New Delhi. (SH: Operation and maintenance of Electrical Installations.)
Operation and maintenance of sub-station equipments including DG Sets, MOEI and Fans, fire fighting, UPS system at INCP, South Block, New Delhi. SH: Refilling and servicing of various type of fire extinguishers.
Procurement of SMF Batteries for ARD system installed in various lifts and batteries for DG sets, under sub division-I BM-II (E) division
Customized AMC/CMC for Pre-owned Products - AIAMC of 64 Nos Inverter 625VA 5500VA with 12V 120AH 135 AH batteries 131 in Nos; AIAMC of 64 Nos Inverter 625VA 5500VA with 12V 120AH 135 AH batteries 131 in Nos; Annual Maintenance Contract (AMC); Monthly..