Loading…
Loading…
4,923 results • Best match
Maintenance of various E&M services at MDC National Stadium, New Delhi during 2025-26 (SH- Replacement of old defective batteries of 160 KVA & 300 KVA USP System) Subwork/Packages: Replacement of old defective batteries of 160 KVA & 300 KVA UPS System...
Provision of split Air Conditioner-Split AC with stabilizer, Water cooler, UPS System for power backup and some electric work at Ayurvedic Dispensary Kapashera in ward no. 132 under Najafgarh Zone.
Comprehensive Maintenance of UPS system
Online UPS Experience with Gov. Required 1 Year (s) Online UPS ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0kva Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT-PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz singlephase160v-260vs inewave50hz Output power Single phase 230V +/-1% sinewave 50 Hz singlephase230v-1sine wave50hz Backup time (Minutes) 120 120 Minimum VAH (VAH) 24000 Warranty for UPS (Years) 3 1, 2, 3, 4, 5 Movable trolly for Batteries Without With, Without, Without trollery but with rack Warranty for battery 1 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for With With, Without 1/5 input and out put Paralleling kit for synchronising With With, Without Installation and Commissioning Yes N/A CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 N/A Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) N/A FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 N/A Voltage Regulation from no load to full load (%) /= 3% N/A 20% Overload limit for minimum 10 minutes Yes N/A Overall Efficiency (%) >/=90% N/A Total Harmonic Distortion(THD) (%) Maximum 3% N/A 50% Overload limit for minimum 1 minutes Yes N/A PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes N/A Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes N/A METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes N/A Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes N/A REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of Yes N/A 2/5 (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes N/A Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes N/A Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes N/A Type Test Certificate No. R-81001295 N/A Type Test Certificate date JAN-2017 N/A Name of Lab BIS DELHI, STQC-ETDC (GOVT. OF INDIA) N/A Address of Lab DELHI N/A As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ashish Dhingra N 110010, Army Cyber Group, Signals Enclave, Rao Tula Ram Marg, New Delhi 2 30 EMD Required No ePBG Required No 3/5
Operation and Maintenance of Sub-Station equipments including DG sets, MOEI and Fans, fire fighting, UPS system at INCP, South Block, New Delhi. (SH :- Annual Comprehensive maintenace of RO system.) Subwork/Packages: Annual Comprehensive maintenance of RO system.
ADDITION ALTERATION OF ALUMINIUM FRAME WINDOWS WITH GLASS BLDG NO P22 P23 P24 P14 P15 P16 P17 PROVISION OF 01 50 KVA UPS ALONGWITH BATTERY BACKUP PROVISION OF COVERED HARD STANDING AT MT PARK AND ADDITION ALTERATION OF BUILDING NO P44 04 NOS OFFRS MD
EOR to Providing and Fixing Split Type AC, 10 KVA Inverter and Water Cooler at SDM Court, Seelampur Complex, Delhi.
E.O.R to providing Geyser, Inverter and CCTV System at Boys and Girls Hostel, Sanskar Ashram Complex, Dilshad Garden Delhi - 110095.
E.O.R to providing Geyser, Inverter and CCTV System at Boys and Girls Hostel, Sanskar Ashram Complex, Dilshad Garden Delhi - 110095.
MAINTENANACE OF E&M SERVICES AT NATIONAL SCHOOL OF DRAMA BAHAWALPAUR HOUSE NEW DELHI SH- SITC OF UPS AND INVERTER
MOEI & Fans and MO electrical appliances of HMPs Bungalows/Flats under North Avenue, New Delhi. (SH : Providing & fixing Inverter System)
Medha make Inverter Duct Filter LHS/RHS Side part No. SP648V22022 or equivalent, sample to be approved before bulk supply.
Supplying and replacement of defective batteries and other accessories of 3 x 100 KVA capacity Riello make UPS system of Department of Trade and Taxes, installed at1st Floor, Vyapar Bhawan, I.P. Estate, New Delhi.
RMO Pump Set, Lifts, UPS system, 3x10 TR capacity package type AC Plant, AC equipments and DG Set installed at Honble LGs Residence and Office Building at Raj Niwas Marg, Delhi as per NIT
i ARMO various E and M services at SGM Hospital Mangolpuri Delhi ii ARMO various Electrical and Mechanical Services at 325 Bedded Bhagwan Mahavir Hospital Pitampura Delhi SH Annual Comprehensive Maintenance of UPS system
M/o Completed scheme under Nazul A/C-II South Zone. Sub Head-Providing and installation of UPS system in divisional office and safety equipments in Community hall at Tekhand village and Zamroodpur village.
Operation & maintenance of Sub-Station equipments i/c. DG sets, MOEI & fans, fire fighting, UPS system at INCP, South Block, New Delhi. (SH: Round the Clock operation of 11 KV HT sub-station equipments.)
ARMO of EI & Fans pump Sub-Station, DG Set, UPS System, Fire Fighting, Fire alarm, ETAC, WTAC system at GOI Press Ring Road Mayapuri, New Delhi. (SH: Providing Electrical Operated Gates at sub-Station )
Operation & maintenance of Sub-Station equipments i/c. DG sets, MOEI & fans, fire fighting, UPS system at INCP, South Block, New Delhi. (SH: Operation and routine/preventive maintenance of fire fighting and sprinkler system.)
Server, Desktop, UPS 20 KVA, UPS 01 KVA, Software Enterprises solution
lead acid battery Lead Acid Battery ( 280 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Lead-Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Lead-Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 88 88 Warranty (Years) 2 Years 2 Years Battery Condition Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 6.8 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn., corresponding Ah Yes. - No.of cells per Battery (No.) 6 Cells for 12 Volt battery - 1/3 CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab HALDIA - Name of the Lab EXIDE - Test Report No. EIL/88/HALDIA/142018 - Test Report Date 1.4.2018 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells, and for Batteries made from them for use in portable applications YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 S K SINGH 110088, FC 50, Integrated Complex, Near Max Hospital, Shalimar Bagh 280 21
Supplying, Installation testing and commissioning of Inverter Type 1.5 TR Split Type Air conditioner
Supply of SMF batteries of different capacities for DG Sets, ARD of Lift and IT Server Room of various location under BM-I(E) Division.
Providing ACs Refrigerator and water dispenser and inverter at various AAMC
As per tender document
Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM with inbuilt isolation transformer IGBT-PWM with inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 15, 30, 60, 90, 120, 180, 240 Minimum VAH (VAH) 12480 12480 Warranty for UPS (Years) 2 2 Movable trolly for Batteries Without With, Without, Without trollery but with rack Warranty for battery 2 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for With With, Without 1/4 input and out put Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of Yes - 2/4 (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. Will provide if required - Type Test Certificate date Will provide if required - Name of Lab Will provide if required - Address of Lab Will provide if required - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Agusthia Minj 110016, Level-5, East Block-7, Sector 1, RK Puram, New Delhi - 110066 1 15
Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM with inbuilt isolation transformer IGBT-PWM with inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 8064 8064, 8000 Warranty for UPS (Years) 3 3 Movable trolly for Batteries Without trollery but with rack Without trollery but with rack Warranty for battery 2 2 Degree of Protection IP20 IP21, IP20 Cabling 5 meters for input and out put With With Paralleling kit for synchronising Without With, Without Installation and Yes - 1/4 Commissioning CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with IS:9000 (part Yes - 2/4 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. NTS/PPTL/UPS-309/04 - Type Test Certificate date 09/10/2015 - Name of Lab NISAKI TECHNOLOGY SERVICES - Address of Lab No.46, Park Road, 2nd main, 10th cross, Wilson Garden, Bangalore-5600 27 - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sushil Kumar 110020, Okhla Industrial Estate, Phase-III 1 15
Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA 2.0 KVA Technology IGBT-PWM without inbuilt isolation transformer IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz Backup time (Minutes) 120 120 Minimum VAH (VAH) 4500 4500 Warranty for UPS (Years) 2 1, 2, 3, 4, 5 Movable trolly for Batteries Without trollery but with rack Without trollery but with rack Warranty for battery 2 1, 2 Degree of Protection IP21 IP21 Cabling 5 meters for input and out put With With Paralleling kit for Without With, Without 1/4 synchronising Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes - 2/4 Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. 00158 - Type Test Certificate date 17-12-2016 - Name of Lab CORTEX - Address of Lab BHWADI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ashok Kumar Jajoriya 110013, NRTCC, POWERGRID, Maharani Bag 400/220 kV Sub Station, Behlolpur Khadar, Opp. ISBT, Sarai Kale Khan, New Delhi 1 15 EMD Required No ePBG Required No
ARMO of EI Substation DG Set water supply pump STP ,Lifts Acs plant, WTAC/STAC unit & fire fighting system at NFSU complex sec-3 &5 Rohini Delhi During 2024-25(SH: Comprehensive Maintenance of inverter and non inverter type Split/Window/Cassette/Ductable Type Air Conditioners)
Additional essential requirements, Online UPS, Workstation with GPU, AI SERVER, Network Switches, Computer Systems
Comprehensive Maintenance of Servo automatic voltage stabilizer and Online UPS at various VREC Offices
Providing of Automatic Phase Sequence Corrector for online ups at A Block 12 Court
12V/9AH Batteries for offline UPS (Q3), 12V/84AH Batteries for Online UPS (Q3)
Multifunction Machines MFM (Q2), Layer 2 Access Switch (V2) (Q2), Online UPS (V2) (Q2)
Construction of Bharat Darshan Park at Panjabi Bagh ward 02-S in West Zone under Waste to Art. Subhead Provision of Lead Acid Batteries, Bollard Lights, C PVC Pipe, Electrical Cable and Electrical Power Distribution Control Panel.
1) RMO E and M Services at Dada Dev Hospital New Delhi 2) RMO E and M Services at Rao Tula Ram Memorial Hospital New Delhi 3) RMO E and M Service at Sardar Vallabh Bhai Patel Hospital New Delhi (SH Comprehensive Maintenance of DELTA Make UPS Systems)
PROVN OF 82.5 KVA DG SET MP HALL BLDG AT HQ TG EME, SPL REPAIR/ REPLACEMENT OF DEFECTIVE POWER MODULES OF 120 KVA 3 PHASE ONLINE UPS AT OLD SERVER OF DIPAC AND SPL REPAIR/ REPLACEMENT OF ELECTRIC CABLE AND LT PANEL IN THE AREA OF 35 INF BDE, SHANKAR
SITC of UPS, Electrical Connections and Air Conditioning System in Manifold Room, Plant Room, Bed Head Panels and Area Alarms at Janak Puri, Super Specialty Hospital, C-2B Janak Puri, New Delhi (SH UPS System)
Annual Comprehensive Maintenance of Servo Voltage Stabilizer, ARD and UPS System at Guru Gobind Singh Govt. Hospital, Raghubir Nagar New Delhi (SH Comprehensive Maintenance of VINITEC make UPS and Servo Voltage Stabilizer in PSA Plant)
RMO of EI and Fans installed at New Block 1 and 2 Saket District Court Complex, New Delhi during the year 2025-2026. (SH Repair and Annual Comprehensive maintenance of fuji Electric make UPS system)
Annual Comprehensive Maintenance of Servo Voltage Stabilizer, ARD and UPS System at Guru Gobind Singh Govt. Hospital, Raghubir Nagar New Delhi (SH Comprehensive Maintenance of VINITEC make Servo Voltage Stabilizer and UPS in PSA Plant)
AM&O (2022-23): Sub Station & DG Set (i/c UPS System) in Parliament House, New Delhi. (SH: Annual Maintenance of 3x1500 KVA Silent Type Perkins Make DG Set at New Parliament House, New Delhi).
Installation of inverter technology based Split type air conditioning system in the various Offices of MoD Sectt., South Block, New Delhi.
R.M.O. of various types of HMPs Bungalows/Flats under South Avenue, New Delhi. (SH : Monitoring and maintenance of 10 KVA Inverter)
Provision of split Air Conditioner with stablizer, Water cooler, UPS System for power backup and some electric work at Ayurvedic Dispensary Sadh Nagar in ward no. 138 under Najafgarh Zone.EEE/NGZ/MCD/2024-2025/84-01
Provision of Split AC with Stabilizer, Water Dispenser, UPS System for power backup and some electric work at MCD Ayurvedic Dispensary Nangli Sakrawati in Ward No.124 under Najafgarh Zone.EEE/NGZ/MCD/2024-2025/91-01
ARMO of EI and Fans, Pump Sub-Station, DG set, UPS System, Fire Fighting, Fire Alarm System, ETAC and WTAC system at GOI Press, Ring road, Mayapuri, New Delhi. Subwork/Packages: Replacement of Data receiver cum Display unit with Data signal repeater and transmitter
ADDITION ALTERATION OF ALUMINIUM FRAME WINDOWS WITH GLASS BLDG NO P22 P23 P24 P14 P15 P16 AND P-17 PROVISION OF 01 X 50 KVA UPS ALONGWITH BATTERY BACKUP PROVISION OF COVERED HARD STANDING AT MT PARK AND ADDITION ALTERATION OF BUILDING NO P44 04 NOS
COMPREHENSIVE MAINTENACE OF PASSENGER/GOODS LIFT UPS SYSTEM OF CAPACITY 300 KVA AND DG SET OF CAPACITY 2X1500 KVA AND 3X1010 KVA INSTALLED AT RESTRICTED AREA (NBC) UNDER GE E/M BASE HOSPITAL DELHI CANTT-10
SITC of Uninterrupted Power Supply (UPS) System for Signalling, Telecommunication, Automatic Fare Collection, Platform Screen Door/Gate System and Emergency Power Supply to E and M at Elevated Stations of .... of Phase-IV of Delhi MRTS.