Loading…
Loading…
3,759 results • Best match
E D Brand Inverter Type wall mount 1.5 ton Split Air Conditioner with 5 star rating-2018
Provisioning of Variable Frequency Drive with Inverter duty motor in LPG pump at LPG Bottling Plant Guna
Supply, Replacement, Installation, Testing and Commissioning of 80 kw on grid Solar Inverter at DABH Airport, Indore.
Supply of BATTERY CUT OFF SWITCH 24 V, TYPE No. 9BS DTC -24, Drg.No.802001022800-V01-0GA for 8-Wheeler DETC Tower Wagon. Accepted make: Inder or similar
Supply of Battery Charger as per Technical Specification attached Brand: NA (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687730158273 dt.21/02/2023)
Line Interactive UPS with AVR (V2) (Q2), Online UPS (V2) (Q2)
Line Intractive UPS with AVR (Q3), Online Ups-IS:9000 (Q3)
Desktop Computers (Q2), Multifunction Machines MFM (Q2), Online UPS (V2) (Q2)
Desktop Computers (Q2), Multifunction Machines MFM (Q2), Online UPS (V2) (Q2)
Desktop Computers (Q2), Multifunction Machines MFM (Q2), Online UPS (V2) (Q2)
Supply of Electronics instruments and Batteries for Online UPS and installation
Server, Layer 3 - Access Switch, KVM Switch, Online Ups- IS:9000
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2)
ALL IN ONE LAPTOP (Q3), MULTIFUNCTION MACHINE (Q3), ONLINE UPS (Q3)
Desktop Computers (Q2), Multifunction Machines MFM (Q2), Online UPS (V2) (Q2)
Desktop Computers (Q2), Online UPS (V2) (Q2), Multifunction Machines MFM (Q2)
Desktop Computers (Q2), Online UPS (V2) (Q2), Multifunction Machines MFM (Q2)
Desktop Computers, 2KVA Online UPS, Banking And Finance Lab ( 1 set )
Desktop Computers (Q2), Multifunction Machines MFM (Q2), Online UPS (V2) (Q2)
Annual Maintenance Service - Desktops, Laptops and Peripherals - Annual maintenance of Computers Printers Scanners Laptop Online UPS and LAN; Annual maintenance of Computers Printers Scanners Laptop Online UPS and LAN
Work for comprehensive annual maintenance contract for HITACHI Hi-Rel make 2x2KVA UPS system installed in ash handling plant of unit no. 3 and 4, 210 MW at SGTPS, MPPGCL, Birsinghpur.
BLDC electric vehicle Motor Training work bench, Lithium ion battery for EV Battery Characteristics Training work bench, Electric Vehicle Training work bench System, Battery management system training work bench in Electric Vehicle, 3 phase Inverter With MPPT boost Converter and Bi-Directional Battery Charger, Adv. 4 Wheeler EV training work bench with Loading Data Extrapolation Facility, Adv.2 wheeler EV sim. with loading and data extrapolation facility bench
Repairing of control panels of gate no 1,2,3,4,8, General maintenance of 3no 250 KVA DG Set, 2 No 125 DG Set and 1 no 40 KVA DG Set and supply of batteries at Madikheda Dam
PROVIDING INVERTER, BATTERY AND OTHER ELECTRICAL ACCESSORIES IN PWD REST HOUSE GYARASPUR, NATERAN, BASODA AND KURWAI DIST VIDISHA
PROVIDING INVERTER, BATTERY AND OTHER ELECTRICAL ACCESSORIES IN PWD REST HOUSE GYARASPUR, NATERAN, BASODA AND KURWAI DIST VIDISHA
Supply and installation testing and commissioning of inverter battery set in rest house harda and khirkiya dist Harda
e TENDER ARE INVITED ONLINE FOR THE SUPPLY OF UPS AND INVERTER MANUFACTURES STOKIST AND AUTHORIZED DISTRIBUTORS FOR THE YEAR 2023-24.
C-AMC services of 3 kVA and 5 kVA online UPS of make-M/s Best Power Equipments (India) Private Limited, installed at various CNG ROs/CGS/Office in all GAs under CGD Jaipur Cluster. GROUP B- Madhya Pradesh State(Guna, Rewa, Morena and Ashok Nagar GA).
Online UPS Online UPS ( 5 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 1.0 KVA As per GeM Catalogue. Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT- PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 15, 30, 60, 90, 120, 180, 240 Minimum VAH (VAH) 1000 Warranty for UPS (Years) 1 1, 2, 3, 4, 5 Movable trolly for Batteries Without With, Without, Without trollery but 1/4 with rack Warranty for battery 1 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes - REPORTS AND Damp Heat : in Yes - 2/4 CERTIFICATION accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. R-164541 - Type Test Certificate date 05-03-2017 - Name of Lab NOREN - Address of Lab NOREN, DELHI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sagar Deelip Mahatme 470002, 321 Field Regiment PIN-926321 c/o 56 APO (Military Station Dhana) PIN-470228 Mob No : 8716924527, 7979020437 5 15
Online UPS Online UPS ( 2 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 3.0 KVA * Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT- PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 15, 30, 60, 90, 120, 180, 240 Minimum VAH (VAH) 400.0 400-640000 1/4 Warranty for UPS (Years) 1 1, 2, 3, 4, 5 Movable trolly for Batteries With With, Without, Without trollery but with rack Warranty for battery 1 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for synchronising With With, Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4.0 * Voltage Regulation from no load to full load (%) /= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) - * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes * Indicators for mains presence, Battery charging and Yes * 2/4 discharging, Output Over Load, Low Battery Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. R-41015563 * Type Test Certificate date 21-05-2019 * Name of Lab Bureau of Indian Standards * Address of Lab 9 Bahadur Shah Zafar Marg, New Delhi-110002, India * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Amit Kumar Yadav 474006, Morar cantt 2 15 3/4
Annual Maintenance Service - Desktops, Laptops and Peripherals - Online UPS 25 KVA; SOCOMEC
All in One PC (V2) (Q2), Online UPS (V2) (Q2) (3 (3 ))
All in One PC (Q2), Computer Printers (Q2), Online UPS (V2) (Q2)
Laptop-Notebook, Online UPS Bidder Turnover (Last 3 Years) 3 Lakh (s)
All in One PC (Q2), Computer Printers (Q2), Online UPS (V2) (Q2)
Desktop Computers (Q2), Multifunction Machines MFM (Q2), Online UPS (Version 2.0) (Q2)
Desktop Computers, Online UPS Bidder Turnover (Last 3 Years) 5 Lakh (s)
Workstation (Q2), Network Attached Storage (NAS) Device (Q4), Online UPS (V2) (Q2)
Desktop Computers (Q2), Online UPS (Version 2.0) (Q2), Multifunction Machines MFM (Q2)
MOEI & fans in CPWD office building at Gwalior during the year 2024-25. SH- Replacement of defective on grid inverter Subwork/Packages: MOEI & fans in CPWD office Building at Gwalior during year 2024-25. SH- Replacement of defective on grid Inverter
As per tender documents
As per tender documents
ONLINE 5KVA UPS, BATTERY, BATTERY STAND, MCB, BATTERY TERMINAL WIRE
Wall Fan, Calling Fan, Gas Chulha Double Burner, Revolving Chair, Executive Chair, Computer Table, Water Geyser, RO Water Purifier, Water Cooler, Battery, Sine Wave Inverter, Online UPS, Desktop Computer, All In One Computer, Laser Printer, ... Scanner, Inverter Split ...
Supplying installation Testing and commissioning of 2 7 KVA inverter system in Dronacharya Lecture Hall under CSWT BSF Indore
WELDING MACHINE, PORTABLE, INVERTER TYPE, SINGLE PHASE, CURRENT OUTPUT: 20 -200 AMPS. AIR COOLED, POWER FACTOR - 0.93 WITH ACCESSORIES.
Servicing of 2 nos. set of Hitachi Hi-Rel make 2x50KVA UPS system during annual over hauling (AOH) and emergency or breakdown visit of unit no. 1 and 2, at SGTPS, MPPGCL, Birsinghpur.
1.5 Ton-Split Air Conditioner A. Technology of AC* : Inverter AC(variable speed) (Q3), Printer Type - LaserJet; Functionality - Single Function (Print Only) ; Printer Output - Black & Wh (Q3)
All in One PC (Q2), Multifunction Machines MFM (Q2), Online UPS (V2) (Q2)
interactive panels and accessories (Q2), Multifunction Machines MFM (Q2), Online UPS (V2) (Q2)