Loading…
Loading…
3,759 results • Best match
Online UPS Online UPS ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 10.0 KVA 10.0 KVA Technology IGBT-PWM with inbuilt isolation transformer IGBT-PWM with inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz Backup time (Minutes) 30 30 Minimum VAH (VAH) 3200 Warranty for UPS (Years) 1 1 Movable trolly for Batteries Without Without Warranty for battery 1 1 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for synchronising With With, Without 1/4 Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with Yes - 2/4 IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. IEC 62040-1 - Type Test Certificate date 2016 - Name of Lab IECEE - Address of Lab NOIDA - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Om Hazela 453441, ARMY WAR COLLEGE MHOW CANTT 2 15 Required No ePBG Advisory Bank State Bank of India ePBG Percentage(%) 10.00 Duration of ePBG required (Months). 14
PROVN OF ONE ADDITIONAL 1 MW INVERTER ALONGWITH CONSTRUCTION OF AIR CONDITIONED HOUSING ROOM FOR SOLAR POWER PLANT AT MHOW
REPLACEMENT OF INVERTER AND BATTERY IN PWD CIRCUIT HOUSE RAISEN, REST HOUSE BADI, SULTANPUR, BEGAMGANJ, GOHARGANJ AND OBEDULLAGANJ DIST RAISEN
Supply, Installation and Commissioning Of Variable Frequency Drive (VFD) With Inverter Duty Motor In 90 KW LPG Pump at LPG Bottling Plant, Ujjain
All in One Computer (Q3), Interactive Panel (Q3), Antivirus (Q3), 10 KVA Online UPS (Q3), 2 KVA Online UPS (Q3), Video Conferencing Camera (Q3), Speakerphone (Q3), PA Speaker (Q3), Printer (Q3), Multifunction Machine (Q3)
All in One PC (Q2), Online UPS (Version 2.0) (Q2), Multifunction Machines MFM (Q2)
Entry and Mid Level Desktop Computer (Q2), Computer Printers (Q2), Online UPS (V2) (Q2)
Average Turn Over of Last 3 Years 3 Lakh (s) Experience with Gov. Required 1 Year (s) Online UPS 5 KVA For Critical Infrastructures ( 8 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed ... GENERIC Online UPS should ... VAH Inverter Technology ... for Inverter India ... MCB/Fuse, Inverter push ... * Inverter efficiency ... battery, Inverter , ... level, Inverter over ... low, inverter overload ...
Inverter (V2) (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
Supply, Installation, Commissioning and Testing of 01 no. 25KW Inverter of Existing Solar Roof TOP plant at CMPDIL, RI-6, Jayant.
Supply, Installation, Commissioning and Testing of 01 no. 25KW Inverter of Existing Solar Roof TOP plant at CMPDIL, RI-6, Jayant.
Inverter (V2) (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
Supply and Installation Interactive Smart Panel with Audio Speaker and UPS Battery
Supply, Installation, Testing & Commissioning of 110 V DC Battery Bank with buyback (Q3)
Supply & Installation of 2 Ton SPLIT AC 5 STAR with Inverter Technology., Supply & Laying of Copper Piping with Nitrile Insulation, Supply and laying of PVC Drain pipe, Supply and Laying of PVC Insulated 3 core 2.5 sqmm cable
Lead Acid Battery, Model BL 1300 RMF, Voltage - 12V, AH - 130 AH, Required Size: 505mm x 182mm x243mm, Item code - AAM-BL-BL 1300RMF, Make: Exide/Amaron/Tata Green only for GODREJ Fork lift.
All in One PC (Q2), Online UPS (V2) (Q2), Headset (V2) (Q2), PA Speaker (Q2)
Entry and Mid Level Desktop Computer (Q2), Multifunction Machines MFM (Q2), Online UPS (V2) (Q2)
Multifunction Machines MFM (Q2), Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2)
All in One PC (V2) (Q2), Online UPS (>10 KVA) With Battery (Q2) (3 (3 ))
Desktop Computers (Q2), Television (TV) (V2) (Q2), Multifunction Machines MFM (Q2), Online UPS (V2) (Q2)
Multifunction Machines MFM, Online UPS, Desktop Computers Bidder Turnover (Last 3 Years) 15 Lakh (s)
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2), Multifunction Machines MFM (Q2)
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2), Multifunction Machines MFM (Q2)
Desktop Computers (Q2), Television (TV) (V2) (Q2), Online UPS (V2) (Q2), Multifunction Machines MFM (Q2)
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2), Multifunction Machines MFM (Q2)
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2), Multifunction Machines MFM (Q2)
Custom Bid for Services - Supply Installation Commissioning of Inverter Part No 91565040 Timer Relay Part No 91521530 for San Diesel Engine Shunter()
Inverter with sine wave output Average Turn Over of Last 3 Years 2 Lakh (s) Experience with Gov. Required 2 Year (s)
Digital Controlled IGBT Inverter Based MIG/MAG Welding system with remote management controller. Make: Panasonic/Esab/Lincoln/Miller/Frounius/Kemppi or Equivalent.
Digital Controlled IGBT Inverter Based MIG/MAG Welding system with remote management controller. Make: Panasonic/Esab/Lincoln/Miller/Frounius/Kemppi or Equivalent.
Supply, Installation, Testing and Commissioning of 2 X 80 KVA Uninterrupted Power Supply (UPS) System in N+1 Parallel Redundant Mode at Main Office Building, Reserve Bank of India, Bhopal (Date of NIT available: June 26, 2025)
SUPPLY OF BATTERY TESTER ( LOAD CELL TESTER ) 2-6-12 V ; 4-500 AH. FIRM SHOULD SUPPLY DEALER CERTIFICATE ALONG WITH MATERIAL. MAKE/MODEL: MECO MODEL BM63 OR SIMILAR MAKE/BRAND: MECO Battery Meter MODE
Entry and Mid Level Desktop Computer (Q2), Multifunction Machine MFM (V2) (Q2), Online UPS (V2) (Q2)
Desktop Computers (Q3), MFP Laser Printer (Q3), 2KVA Online UPS (Q3), Banking and Finance Lab (Q3)
Entry and Mid Level Desktop Computer (Q2), Multifunction Machine MFM (V2) (Q2), Online UPS (V2) (Q2)
Entry and Mid Level Desktop Computer (Q2), Multifunction Machine MFM (V2) (Q2), Online UPS (V2) (Q2)
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2), Multifunction Machine MFM (V2) (Q2)
All in One PC (Q2), Online UPS (V2) (Q2), Multifunction Machines MFM (Q2), Laptop - Notebook (Q2)
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2), Multifunction Machine MFM (V2) (Q2)
Desktop Computer Intel Core, Document Scanner, NAS Drive, Hard Disk Drive Capacity 8 TB, Online UPS
Enquiry for supply of Step Down transformer Copper Wouded Capacity 1500 VA for Battery Charger Primary Side Tapping 0 to 190 V, 220 V , 230 V , 240 V Secondary Side tapping 0 to 28 Volt, 30 V , 34 V , 40 V Under Datia.
Supply of Battery and SDHC Card
Supply and installation of 72 Nos. 2 Ton 3 star fixed speed and 12Nos 1.5 Ton 5 star inverter Split type Air Conditioners
Okaya Inverter 1.5 KVA Brand: Okaya (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687712198212 dt.25/03/2025)
Heavy duty portable single phase inverter welding machine as per technical specification attached. To be procured from OEM or OEMs Authorized distributor only.
SITC of new solar inverter for existing 15 kwp solar power plant i/c all connections etc. as reqd at KV Datia Subwork/Packages: work
Work Station With Monitor (Q3), 1 KVA UPS (Q3), Corel Draw graphics Suit (Q3)
Supply, Installation, Testing & Commissioning of 2 Sets of 2000AH, 220V DC Battery Bank with Buyback
All in One PC (Q2), Online UPS (V2) (Q2) MSE Exemption for Years of Experience and Turnover