Design, Supply, Installation, Testing and Commissioning of Prefabricated Packaged/Portable container based Waste Water Treatment Plants having capacity of 10 KLD including operation and maintenance for 10 years at NHP at Pocket-B, Dilshad Garden (Han
Operation and Maintenance of 28 nos. water chiller plants and 06 nos. R.O. plants of piaos situated at MNI, Azadpur
Potable water purification system Potable Water Purification System ( 27 ) Technical Specifications Specification Specification Name Values Variant EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier electricallyoperatedrev erseosmosisbasedwate rpurifier Ultraviolet (UV) LAMP Yes Yes, No Ultra Voilet (UV) Lamp power consumption 11 N/A STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection N/A Number of float valves/sensors 3 INPUT PARAMETERS Input Water TDS 1000 1000, 2000, 3000, 4000, 5000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 25-35 25-35, 30-40, 90-100 Output Water of RO system Conforming to Indian Standard IS 10500(latest) N/A Output water capacity (Litre/Hour): 10 10, 25, 50, 100, 250, 500 Arsenic and Floride true 1/4 removal capability Misc, warranty etc Thin-film composite membrane Yes Yes, No High Pressure Pump Yes N/A Raw water/Chemical Raw water/Chemical Cleaning PUMP Yes Yes, No Pre Filter Vessels: Yes Yes, No Micron Filter Yes Yes, No Membrane Housing No Yes, No Auto cut No Yes, No No of candles (Nos) 3 Installation Type Wall mounted wallmounted Warranty period ( for free replacement of machine 2 2, 3 Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 2 2, 3 Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes Yes, No Chloride & Flouride removal facility Yes with Pump Yes with Pump, Yes without pump, No Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 Yes N/A Test certificate No and date: CE/045-A 27-09-2013 to 26/9/2018 N/A Name and Address of laboratory which conducted Test: Swiss Cert Pvt Ltd, best sky tower, netaji subhash place, pitampu ra, Delhi-110034 N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sameer Milan Banerjee 440013, MOIL LIMITED, MOIL BHAWAN, 1-A, KATOL ROAD, NAGPUR-440013 27 15 2/4 EMD Required No ePBG Required No
Design, Supply, Installation, Testing and Commissioning of Prefabricated Packaged/Portable container based Waste Water Treatment Plant having capacity 50 KLD (Three nos.) including operation and maintenance of ten years
Supply, Installation, Testing and Commissioning of RO Plant including O and M for 15 years at OKHLA STP
Running Maintenance and Operation of STP, RO Plant, Hydraulic pumps and submersible pumps at Squash and Badminton Stadium.
Custom Bid for Services - SPLY AND FIXG OF RO MEMBRANE, Custom Bid for Services - CAMC OF RO PLANT
Balance common services works viz Fire fighting, UG tank and Pump Room, WTP, ETP, STP (Including Collection Chamber), Sewer line, Effluent line and Substation work and allied Civil works, etc. in National Capital Region
ARMO of International Boys Hostel of 500 capacity and Food court including water supply, sanitary installation, internal electrical installation, Fire Fighting System, Fire alarm system, Sub-Station, Lift, DG Sets, CCTV, RO Plants, Access Control System and Solar PV System at IARI Pusa, New Delhi. ( SH SITC of wireless data receiver cum Digital data transmitter with capacitance based Battey powered data signal ) Subwork/Packages: SITC of wireless data receiver cum Digital data transmitter with capacitance based Battery powered data signal
Design, Supply, Installation, Testing and Commissioning of Prefabricated Packaged/Portable container based Waste Water Treatment Plants having capacity of 25 KLD including operation and maintenance for 10 years in Distt. Park at Nand Nagri Ph-II. (Sp
Design, Supply, Installation, Testing and Commissioning of Prefabricated Packaged/Portable container based Waste Water Treatment Plants having capacity of 25 KLD including operation and maintenance for 10 years NHP at 1536 and MIG and LIG Flats East
Design, Supply, Installation, Testing and Commissioning of Prefabricated Packaged/Portable container based Waste Water Treatment Plants having capacity of 25 KLD including operation and maintenance for 10 years at Park and RSP AND CGHS at Mayur Vihar
Operation and routine maintenance of E.I and Fans and CCTV, pumps, firefighting and fire alarm system, Lifts, HVAC Plants, STP/ETP, R.O. Plant, DG Set and EPABX system etc.
Annual Maintenance Contract (AMC) for window/ Split Air Conditioners and Reverse Osmosis (RO) with Water Coolers Installed at Zonal Office Building Lajpat Nagar in ward No. 57-S under Central Zone. (FY- 2020-21).
Supplying, installing, testing and commissioning of RO Plant with capacity 10,000 ltrs. at District Centre, Paschim Vihar (Specialized Work).
Supply, Installation, Testing and Commissioning of 20 MGD RO Plant including 7 years of O and M at Rohini
Supply, Installation, Testing and Commissioning of 10 MGD RO Plant including 7 years of O and M at Chilla
Supply and Replacement, Repairing and Renovation of Filtration Plant and cleaning of water and overhauling of 40 KVA D.G. Set of Swimming Pool at HNSC.
Clearing Jungle at Haider Pur WTP
Clearing the jungle at Haiderpur WTP.
Providing water effluent at Bawana WTP.
Engagement of unskilled (Sweepers/S.G Beldars) and Semi Skilled (Mason, Carperter, Plumber Manpowerfor maintenance at Haiderpur water works, Bawana WTP and Varun Niketan in the division of Dy. SE(Civil) plant WW-HP.
Audio Amplifier (Q3), Drinking Water Cooler - as per IS 1475 (Q3), Potable water purification system Reverse Osmosis or UV based (Q3), Professional Large Format Display (Q2), Bluetooth Speakers (Q3), Bldc Pedestal Fan-IS:1169 (Q3)
MOEI and fans, Power plug, street/compound light and RMO sub-station equipments stand by 320 KVA DG Set, Pump set for water supply, wetriser i/c sprinkler system, Automatic fire alarm, PA and sound system in CCRAS Building at Janakpuri New Delhi.(SH: ... and RO Plants )
Running operation along with annual comprehensive maintenance of 02 nos. 320 KLD sewage water treatment plant installed at Housing Pocket-7, Sector A1 to A4, Narela for the year 2025-26
SITC of 02 Nos. Chlorinators of 40 Kg/hr Capacity at Post Chlorination System (North and South) Water Treatment Plant Haiderpur Phase-I along with allied accessories, under C.W.A. (WnS)-II.
Repair, Servicing and Replacement of Required Spare Parts of Absorption system and Leak Detector System at Pre, Post (north) and Post (south) of Water Treatment Plant, Haiderpur Phase - II.(Make-Metito)
Design, Supply, Installation, Testing and Commissioning of Prefabricated Packaged/Portable container based Waste Water Treatment Plant having capacity 10 KLD (Two Nos.), 25 KLD (One No.) and 50 KLD (One No.)
Potable water purification system Potable Water Purification System ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis ... Operated Reverse Osmosis based ...
Restoration of cut made for water supply system including O M of Transmission Distribution Pipes, Pumping Stations, Service Connections and Consumer Meters with DMA formation and NRW Reduction in Chandrawal WTP Command Area Package-2 (West) at Ros
Shifting of 500 mm dia Rising Main from Tahirpur Rising Main to clear water tank (main UGR) of WTP Sonia Vihar for feeding of water to 5.90 MGD new UGR Sonia Vihar under ACE (M)-2
Hiring of portable flowmeter with all accessories at Bhagirathi WTP and Sonia Vihar WTP command area under Bhagirathi Plant.
Mo completed scheme of Nazul A c II of SWZ
RMO of 50LPH RO and 500LPH RO plant of Surya Envoiropure make under EMSD-III, South East PWD Sunlight Colony
SH-Designing, Providing, installation and commissioning of R.O. Plant having capacity 10000 ltr/hr at in-situ development project of Kathputli colony at Shadipur including 3 years warranty, operation and maintenance.
Split AC 1.5 Ton 5 Star, Windoow AC 1.5 Ton 5 Star, Water Cooler Stainless steel 150.150 Ltr, Supply and fix reverse osmosis plant of output capacity 60 ltr per hour single phase electric driven complete
Repairing, Servicing and Replacement of Stirrers, Agitators (No. 01 to 06) installed inside the Alum Solution Tanks in Chemical House at Water Treatment Plant, Haiderpur Phase-II under C.W.A. (WnS)-II division.
Supply of Medium Basicity Poly Aluminum Chloride (PAC-10) in liquid form ISI marked, manufactured from virgin raw material for the treatment of low to high turbidity surface raw water for drinking purpose at various water treatment plants of DJB co
Miscellaneous and emergent works at Bawana WTP.
Maintenance of existing garden at Bawana WTP.
Construction of Recharge Pits at Bawana WTP.
Supply of Enamel Paint for Bawana WTP.
Premixing of internal road at Okhla WTP.
Improvement of areas at Sonia Vihar WTP.
Premixing of internal road at Okhla WTP.
Maintenance of existing garden at Bawana WTP.
Renovation of various UGRs at Bawana WTP.
Repairing/ Renovation of Filtration plant and chemically cleaning of water for Swimming pool at PDKP, CSC, Kanti Nagar (green area) under PDKP, RSKP, MDCSC and RSC, DDA.
Deployment of technician cum operator for daily regulation and maintenance of RO plant at Pkt 1C, Sector A1 to A4, Narela.