Loading…
Loading…
379 results • Best match
Improvements to Sangamner Wadgaon (SH-50) to Nilwande (SH-65) to Kauthe Kamaleshwar to NH-160D (MDR-10) Road Tal.Sangamner Dist.Ahilyanagar (Part SH-50 Km. 115/400 to 121/700, SH-65 Km 68/900 to 72/100, MDR-10 Km 0/00 to 10/500, Total Project Length-
19 Architect 5000 7500
Supply, Installation Testing and commissioning of surveillance system at DIHM Lajpat Nagar-IV, New Delhi .
Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 128 Gbps and packet forwarding rate of 95Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 4 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: FCC, CE marked, UL/EN, RoHS and relevent, MTCTE(TEC)/BIS Compliance/certification as applicable , etc. complete as required. 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each cooper port supporting 802.3at PoE+min.
Provision of Soil Investigation and Consultancy Services for Provision of Technical Accommodation for COSMOS Facility at Site K
Building including internal services : Consultancy Services for detailed planning, designing and detailed engineering including preparation of detailed architectural, structural and service drawings etc., for the proposed buildings/ structure including internal services as per detailed scope of work given in Para-2.1(A) including proof checking for structural design from third party.
Event management of Ayurveda Expo at Kannur
Providing a faccade at the main entrance with metal/ wooden material, as approved by the architect along with necessary boards etc. (Design will be supplied by the client before the prebid meeting) 40 ft length and 20 ft height with scaffolding support.
SUPPLY, INSTALLATION, TESTING and COMMISSIONING OF CCTV SURVEILLANCE SYSTEM AT 140 WAREHOUSE LOCATIONS
Supplying , fixing and configuring ethernet managed ethernet each switch of minimum of 24 ports 10/100/1000 Base-T PoE+ ports with min 180W power and 2x 1G SFP ports and 1 x Out of Band IP based management Port with CL1 provided, switch of min. 36 Gbps or more with non-blocking architecture forwarding rate of 26.8 Mpps rack, equipped with minimum 512MB RAM and 128MB flash, should have LED indicator for per port status, FAN, PSU and Management status and sustain 0°C to 50°C OT and 10% to 95% RH as directed. It should support for IPv6 , cover transmission distance of 250 meter. The swithching and routing should have 16 K MAC Address, 255 active Vlans, 802.1D spanning Tree, 802.1w, 802.1s, should have BPDU Guard, support aggregating and load balancing, 802.1 AK for dynamic VLAN propagation, Local and Remote port mirroring, Link Layer Discovery Protocol (802.1ab), MAC address tracking and address addition, delete or movement. The secutrity LA database for RADIUS Authentication for 802.1x login, SSH-2, SCP for secure management, dynamic arp inspection, DHCP snooping with min 50 ACL entry support. Management should consist scheduled archiving / uploading of configuration and system log to a central server, Auto-install support for firmware images and configuration files and vendor should submit Mfr Test Certificate along with supply as directed by Engineer in charge as per technical specification no. 1 complete.
Appointment of an Event Management Agency on turnkey basis for Designing, Execution and Management/ Supervision of arrangements, activities and ancillary services for an Event being organized in conjunction with Republic Day Celebrations 2026
Office set up of Concerned Ministries ( Ministry of Road Transport,NECRT,MoEF&CC,Department of Post, Council of Architect, Ministry of Jal Shakti etc.) Water Proof Pagodas (10mtr x 5mtr) Structure each with wooden platform base of 10 cm, carpet with each to have 12 light fittings of 40 watts each or compatible LED light fittings, Furniture- Octonorm Table 3’x 1.5’ - 08 Nos, Banquet chairs with chair covers 8 nos, Power Points 08 Nos, Spot lights -15 Nos, Dustbin -02 No, etc. with Modular structure inside. Each Modular structure within each theme Pavilion to have Presentable Almirah (all equal size) with lockable facility to be placed in each Central Ministry/ Department Pavilion pagoda and 1 No. fascia. Each Pavilion (10 mtr x 5 mtr ) to have additional average Electricity load of 6 KW for each pavilion including Electric load required from 22nd January,2025 for fabrication of stalls)