Loading…
Loading…
2,777 results • Best match
REPAIR/ REPLACEMENT AND MAINTENANCE OF BUILDING PANELS ALONGWITH ALLIED WORKS AND REPAIR/ REPLACEMENT AND MAINTENANCE OF STORAGE TYPE WATER HEATERS, CEILING FANS, WALL FANS, EXHAUST FANS AND ELECTRIC METERS UNDER GE (AWC) MHOW
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, pipes etc. and getting out all excavated material in any type of soil complete all as specified and directed.
REPAIR AND MAINTENANCE OF EXTERNAL LT POWER DISTRIBUTION NETWORKS INCLUDING REPLACEMENT OF UG CABLES, POLE PAINTING, MCCBs, LT PANELS AND OTHER ASSOCIATED COMPONENTS AT ALTINHO, BAMBOLIM AND OTHER LOCATIONS WITHIN THE AOR OF AGE E/M UNDER GE PANAJI
M&L for Checking/meggering of UG cable fault of any size/core and taking out the damaged portion of cable from trenches and removing the fault portion of cable and checking, jointing the same with proper cable end jointing kit and testing for smooth functioning of complete cable and re-laying the same after testing of following size . Notes : (i) Excavation/earth work/returning filling/relaying of brick and relaying soft soil for cushioning deemed to including the job. (ii) Extra cable will be measured and paid under relevant item. iii) Joint kit required will be measured and paid separately under relevant item.
Construction of ACB Police Station (G + 1) at Botad, Dist. Botad. [Including Electrification]
laying of cable below ground / road surface for enclosing cable and
rRenovation of existing hostel rooms, stair case, reception, dining, revamping of Water Fountains, Terrace water proofing of hostel, training blocks and other Miscellaneous Works including Electrification works.
Supply and Laying, Installation, Cable tagging (>&)> continuty testingof CAT6 cable , ATC Braided, Unarmoured (>&)> Overall FRLS PVCSheathed Co-axial Cable in cable tray/PVC conduits.
SPL REPAIR AND STRENGTHENING OF RCC STRUCTURE AT KENDRIYA VIDYALAYA PANAGARH UNDER GE PANAGARH (DEPOSIT WORKS)
Supply and lay for dry river sand filling for cable protection with at layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying, complete all as specified and directed. [Note : (a) Total Qty : 7.00 (Part-IV) + 161.00 (Part-V) = 168.00 (b) Punned thickness shall be measured]
3 LPE COATED CARBON STEEL PIPELINE LAYING AND ASSOCIATED WORKS IN Jehanabad GA (GROUP A)
Supply, installation, Testing & Commissioning of Test lead Points (TLP) including weather proof Test Lead Box as specified in specif ication with backlite strip, bolt terminals, 4” dia heavy duty pipe at top end to fit the test lead box and base plate welded at the bottom including MS bend for concrete Base, Bend, Cables, pipe to cable connection, Epoxy Encapsulation & Miscellaneous such as con nectors, Excavation and backfilling trenches for cable laying & Pin Brazing etc. complete in all respects. The work shall include su pply & fixing of a non corrosive name plate containing the details like KM location, identification, TLP No, Direction of flow, conn ection scheme, type etc., on the side of Top box including the cost of all labour, materials, tools & tackles etc. cables shall be a nnealed high conductivity, tinned, stranded copper conductor, XLPE insulated, 650/1100 V grade, PVC sheathed or as per specification .