SPECIAL REPAIR OF OFFICERS GUEST HOUSE BLDG NO P 65 AND PROVISION OF IRON NET INSTALLATION ON THE TOP OF STORAGE WATER TANK SWT AT BACK SIDE OF MAIN BUILDING AT CQA SA ICHAPORE UNDER GE NORTH KOLKATA
... unserviceable sub main wiring all as specified and directed (Note : (i) Three run of 2.5 sqmm cable one run of PVC conduit shall be measured and paid as one unit. (ii) Cost of wall cutting if any for laying of cable and also making good surfaces are deemed to be included in unit rate).
MYS Augmentation of Mechanised Laundry from 3.5 Ton to 7 Ton / Day capacity.
for safety of cables. NS 12.00 Set 5436.01 65232.12 AT Par 65232.12 Description:- L.T. Earthing arrangements for hard soil using 50 mm C-Class GI Pipe- 2.7 Mtr length,
REPAIR/MAINT OF DG SET AND ALLIED WORKS SERVICES AT AFS PHALODI
M&L in replacement for Earthing complete with galvanised steel earth plate electrode 60cm X 60 cm X 6 mm thick, buried... 1.5 meters below normal ground level, connected to and inclduing GI Strip 25mmx4 mm as earthing lead, by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 5 of MES SSR Part I and testing on completion inclduing excavation and earth ...
Construction of IREL Wellness and Wisdom HUB at Karithura under CSR 2026 27
... point / exhaust fan point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLSPVC insulated copper conductor single core cable etc as ...
RENOVATION OF HOUSE NO.1620 (TYPE-VII), SECTOR-39, CHANDIGARH UNDER EECP DIVISION NO.4, CHANDIGARH (IBM NO.W4/2026/26094).
DSR 8.10 LED Batten light (System lumen efficacy ≥120 135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material... P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till ...
Rajkot Division:- Replacement of old dilapidated Type-II quarters at THAN -9 Nos, Ramparda-8 Nos & Dahisara-01 Nos (Type-III) and Okha-16 Nos. Type-II.
... crystalline panel complete with all accessories, monitoring system, inverter, structure cables, net metering etc complete with five years' warrantee - Design, supply, installation, testing and commissioning of "ON GRID" Solar Photovoltaic power plant with required ...