Loading…
Loading…
970 results • Best match
REQUEST FOR PROPOSAL FOR EMPANELMENT OF LAW FIRMS / LAWYERS/ LEGAL COUNSELS AT IIT INDORE
End-to-End Cleaning, Sanitation and Sanitization Solutions for IIT Indore
Biennial Maintenance Contract and various piece meal maintenance job for Turbine and Auxiliaries Area, 2X250MW of Unit 5 and 6 under TMD, STPS
TG Lub Oil Cooler Cleaning & Servicing ( as per scope of work. )
Work of annual R and M of Shakti Sadan Building and Officers Flat Complex, PSTCL, Patiala for FY 2026-27
Routine cleaning,sweeping dusting, washing of toilets ,lifting of garbage from offical dustbins & dumped in main garbage collection area etc. at Shakti Sdn Patiala, PSTCL offices at HO & officers flats at Patiala (10 No. full time sweepers). Departmental rates = (Basic Rate as applicable) 11726.40+ (EPF@ 13% on Basic Rate as applicable) 1524.43+(ESI@ 3.25% on Basic Rate as applicable) 381.11+ (Bonus @ 8.33% on Basic Rate) 976.81 + Maximum allowable service charges on Basic Rates @ 2.5%) 293.16 = 14901.91
Operation and maintenance of 68 Nos.of Toilet blocks with existing free urinals and Sewerage network in Koyambedu Wholesale Market Complex Chennai 107 for a period of one year
Operation and Maintenance of 68 nos of toilet blocks at Vegetable market, Fruit market , Flower market & 10 nos of urinals at KWMC including maintaining of Water Supply and sanitary network by engaging cleaners for 3 shifts per day (18 nos in 1st shift (6 am to 2.00 pm ),18 nos in 2nd shift (2.00 pm to 10.00 pm) and 9 nos of 3rd Shift (10.00 pm to 6.00 am )), & Plumber-cum supervisor 3 Nos per day (1nos 1st shift (6 am to 2.00 pm ),1nos 2nd shift (2.00 pm to 10.00 pm) & 1nos 3rd shift (10.00 pm to 6.00 am )).Toilet blocks should be cleaned by engaging 12 Nos.of high pressure washer for all perishable markets. The work includes cleaning of toilets by using high pressure washer, operation of motors and valves to ensure uninterrupted water supply to the toilet blocks, sweeping and mopping of floors in toilet blocks, cleaning of urinals, water closet, washbasins, etc Complete., by using detergents / disinfectants round the clock. The rate includes rectification of minor repairs in water supply, including the cost of all the Consumables such as Phenoyl, Bleaching Powder, Broom Sticks, Aluminium Bucket, mob sticks,Dust bin ,Rigid plastic Mug,Wiper &Toilet Cleaning liquid etc., and all complete as directed by Departmental Officers during execution.
Project Supervision Services Agency (PSSA) for Road Safety Projects (RSP) of Southern Railway
services/parts & services for cleaning /
REPAIR/ MAINT OF CERTAIN INTERNAL ROAD OF ZONE-I AND II IN AOR OF AGE B/R-I UNDER GE PANAGARH
M&L Bituminous semi dense asphaltic concrete, 40mm consolidated thickness with minimum 5.5% binder with paving bitumen (VG-30) [Mix Design criteria as per SSR Part-I Clause 20.B.2.11, or as per MoRTH by Marshal method (Ref table 500-12 to 500-16)] coarse aggregate, fine aggregate, filler cement (OPC - 43 Gde) as per recommendation of design by weight of total mix from hot mix plant, rolled by with 8 to 12 tonne vibrating (tandom) road roller to confirm uniform surface and compacted to required camber and gradient including preparing black top surfaces by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. and applying evenly a tack coat of rapid setting cationic bitumen VG-10 conforming to IS : 73 at a rate of application of 0.3-0.4 kg/sqm on bituminous surface as specified in Table 500-5 of MoRTH Specification for Road and Bridge Works 2013, using mechanical sprayer, complete with mechanical paver, complete all as specified and directed. [Note : (i) Work shall be executed after approval of design mix of semi dense asphaltic concrete by GE.(ii) Calibration of Hot Mix Plant shall be submitted to Engr-in-Charge for approval.(iii) Payment shall be made to Contractor after submission of approved design mix, Bitumen Extraction Report, Road Roller Register & Calibration Report.(iv) Exact qty of binder to be used shall be ascertained by Design Mix.(v) Minimum 5.5% binder shall be used. However, in case more than 5.5% of binder content is required as per design mix, the same shall be provided by the contractor at no extra cost to dept.(vi) All testing charges shall include in unit rate quoted by bidder.]