Construction of Community Hall in Dussehra Ground, Mukherjee Nagar, ward no. 13/CLZ. Sub head Consultancy services for structural design drawings, mechanical, electrical, plumbing MEP operations alongwith soil investigation for Construction of C
Providing comprehensive consultancy services for preparation of architectural, structural and allied engineering designs, drawings and detailed estimates for construction of Community Hall building including conducting soil investigation and submission of detailed soil investigation report indicating safe bearing capacity, soil profile, depth of water table, depth of filled-up soil, rocky strata and other relevant geotechnical parameters, preparation of concept plan and preliminary drawings, preparation of architectural layout plan, floor plans, elevations, sections and site development plan, preparation of detailed structural design and drawings for foundation and superstructure including columns, beams, slabs, staircase, lintels, chajjas etc. along with complete reinforcement details as per relevant IS Codes, structural design and drawings for underground/overhead water tanks, sump, retaining walls and other ancillary structures, preparation of layout plans for plumbing system, water supply lines, drainage system, sewerage network, storm water drains and internal roads required for site development, preparation of detailed estimate based on prevailing DSR/Approved Rates including cost of civil works, MEP services such as electrical, HVAC, fire fighting and plumbing works and external development works, incorporation of Rain Water Harvesting system, fire safety measures, green building norms (if applicable) and barrier free access as per statutory requirements, preparation of BOQ, tender documents and technical specifications, coordination with concerned departments for obtaining necessary approvals, vetting and statutory clearances wherever required, proof checking/vetting of structural design wherever required, providing necessary revisions/modifications during approval stage as well as execution stage, providing consultancy during construction stage including clarification of drawings, structural stability related inputs and issuance of revised drawings as per site conditions, submission of complete set of drawings, structural design calculations and reports in triplicate including 06 hard copies and soft copy in editable and PDF format, complete in all respects as per direction of Engineer-in-Charge.
Estimate for Installation of New motor Pump set/Panel in Civil line boosting station in ward 27, Div 3B, under MCG. Re-call
Horizontal centrifugal pump has 150 hp motor power, optional input voltage 3 phase AC 220V/230V/240V, 380V/400V/415V to 440V/460V/480V and optional input frequency 50Hz/60Hz for sale. A. 150 hp centrifugal pump with maximum flow 140 Lps, maximum head 45m and same diameter of inlet and outlet , can be used for HVAC and refrigeration water circulation, high-rise building pressurized water supply, etc.
Construction of new Community Hall Vijay Nagar in Mukherjee Nagar ward no. 13/CLZ. Sub head Consultancy services for structural design/ drawings, mechanical, electrical, plumbing MEP operations alongwith soil investigation for construction of new
Providing comprehensive consultancy services for preparation of architectural, structural and allied engineering designs, drawings and detailed estimates for construction of Community Hall building including conducting soil investigation and submission of detailed soil investigation report indicating safe bearing capacity, soil profile, depth of water table, depth of filled-up soil, rocky strata and other relevant geotechnical parameters, preparation of concept plan and preliminary drawings, preparation of architectural layout plan, floor plans, elevations, sections and site development plan, preparation of detailed structural design and drawings for foundation and superstructure including columns, beams, slabs, staircase, lintels, chajjas etc. along with complete reinforcement details as per relevant IS Codes, structural design and drawings for underground/overhead water tanks, sump, retaining walls and other ancillary structures, preparation of layout plans for plumbing system, water supply lines, drainage system, sewerage network, storm water drains and internal roads required for site development, preparation of detailed estimate based on prevailing DSR/Approved Rates including cost of civil works, MEP services such as electrical, HVAC, fire fighting and plumbing works and external development works, incorporation of Rain Water Harvesting system, fire safety measures, green building norms (if applicable) and barrier free access as per statutory requirements, preparation of BOQ, tender documents and technical specifications, coordination with concerned departments for obtaining necessary approvals, vetting and statutory clearances wherever required, proof checking/vetting of structural design wherever required, providing necessary revisions/modifications during approval stage as well as execution stage, providing consultancy during construction stage including clarification of drawings, structural stability related inputs and issuance of revised drawings as per site conditions, submission of complete set of drawings, structural design calculations and reports in triplicate including 06 hard copies and soft copy in editable and PDF format, complete in all respects as per direction of Engineer-in-Charge.
Operation and maintenance of water booster as well as repair of water supply leakage for the month of April to Sept. in ward 5, under MCG.
Horizontal centrifugal pump has 50 hp motor power, optional input voltage 3 phase AC 220V/230V/240V, 380V/400V/415V to 440V/460V/480V and optional input frequency 50Hz/60Hz for sale. 50 hp centrifugal pump with maximum flow 110 Lps, maximum head 35m and same diameter of inlet and outlet , can be used for HVAC and refrigeration water circulation, high-rise building pressurized water supply, etc.
TOTAL TURNKEY INTERIOR FIT OUT WORKS IN THE EIGHTH FLOOR (B- BLOCK) IITMRP
HVAC vendor shall co ordinate with other vendor's (like fire , Electrical etc) and make a provision in their system so that in case of any fire / un even incident, the entire power supply to HVAC shall get disconnected and all the HVAC system supplied by the vendor shall stop on safety. The cost for the system integration including potential free contact provision shall be borne by the HVAC Vendor. In case if cable required then the same shall be quoted additionally after prior approval from consultants / architects (If not considered by electrical vendor).
Construction of NCDC Branch Centre and BSL -3 Lab Building at UCHC Campus, Shivpur, Varanasi on Engineering, Procurement and Construction (EPC) Basis.
BSL-3 Laboratory Buidling with BSL-3 , BSL-2 and other lab works Specialized equipments, systems and works for BSL-2, BSL-3 and other Lab Specialized Works High Containment laboratory work in NCDC BSL-3 Building shall include specialized internal walls, ceiling and finishing works i/c aluminium coving, door, floor coving, self levelling epoxy flooring, HVAC works including HEPA filters works BIBO/containment housing, Electrical Works, Containment barrier double door autoclave with bio-seal, Effluent decontamination system, Building and Lab management system, CCTV system, Access Control system, Walk-thru-shower system + BLED room, Laboratory work stations, modular laboratory work stations, Double door class 100 dynamic pass box, biosafety door for transfer/decon air-lock and showers, Double door autoclave, compressors, dunk tank, Ventilated type garment storage cabinet, garment storage lockers, Effluent decontamination system for BSl-3 lab 2 nos 750 litre each (1W+1S) with steam boiler and accessories, Water treatment/softening plant, VHP pass Box, Eye-wash stations, Lockers etc and associated works including handing over, validation and certification from Department of Bio-Technology (DBT) complete as per scope of work and directions of Engineer In charge.