Connecting Internal Storm Water Drains of S Block and P Block of Uppal Southend to the Master Drain, Installation of Motor in Low-Lying Area of S Block, and Construction of RCC Box Type Storm Water Drain from Vega School up to GMDA Master Drain at So
Horizontal centrifugal pump has 50 hp motor power, optional input voltage 3 phase AC 220V/230V/240V, 380V/400V/415V to 440V/460V/480V and optional input frequency 50Hz/60Hz for sale. 50 hp centrifugal pump with maximum flow 110 Lps, maximum head 35m and same diameter of inlet and outlet , can be used for HVAC and refrigeration water circulation, high-rise building pressurized water supply, etc.
SHIFTING OF AIR CONDITIONING MACHINES OF WARD 09, 10 AND 11 INNEWLY CONSTRUCTED ROOMS ADJACENT TO RESPECTIVE WARDSALONG WITH ALLIED WORKS AT GOVT. SMGS HOSPITAL JAMMU.
DSITC of new plenum chamber for each ward HVAC machines arrangement along with allied workslike thermal insulation, insulation with heavy density nitrile rubber covered with glass cloth and star bond, Duct lining with open cell nitrile rubber etc. as per site requirement and as per direction of Engineer-in-charge.
AMTC OF 15 MLD STP UE Kurukshetra Supply of blush cutter machine and tube lights Panel Board and MS pipe at 15 MLD STP Kurukshetra complete in all respect and other work contingent thereto
Supply of tubelight welded steel tubing from Phillips Tube Group (for automotive, HVAC, etc.) Philips brand LED tube lights/battens (energy-efficient STP lighting). Phillips Tube Group makes custom steel tubes, while Philips offers various energy saving LED tubes like Slimline, AstraLine, and StarBright for different brightness and aesthetic needs, emphasizing long life and cost-effectiveness.
Extension of Terminal Building Towards City Side Including Provision of Canopy, Construction of Kerb Area and Associated Road Works at Civil Enclave, Hindon Airport, Ghaziabad UP Recall
Engineering Procurement and Construction of extension of Terminal Building along with Kerb area for Kerb amenities etc. with Site development and offices as per drawing, site survey, Earth Work, RCC / Composite Steel Structure/Steel Structure, Roofing system and steel structure, Brick Work / AAC Block work, Aluminium / Glazed façade, Stainless Steel Railings, Cladding works with ACP or as approved by EIC, Flooring, False Ceiling, Partition, offices, polycarbonate canopy, Rain water harvesting, Portable container project office, Interior Works and Sanitary, Plumbing and Water Supply works, Drainage system, Utilities, Internal & External Electrification , Power Supply System including LT panel, etc. & UPS, HVAC with VRV/VRF system, split ACs, Sliding door, Air curtain, Fire Hydrant, Fire Alarm Detection System, Internal, External Illuminated and Non-Illuminated Way Finding Signages and Emergency escape signages, Building Signage, PA system etc. as per drawings including dismantling, shifting of the existing services as per Specifications, DBR, Scope, Codes and Practices and all other requirements as contained in tender document. The detailed design of facilities shall confirm to standard specified by ICAO, DGCA, AAI, MORTH, IRC, NBC, CPWD, IS, IEC etc. wherever required and in conformity with regulations regarding permissible heights, locations requirements etc. i/c all other works covered under Scope of work and meeting all relevant statutory requirements i/c optimization of energy efficiency complete as required. Scope of work shall also cover DLP of 02 years after actual completion of work thereafter Note: (1) The bidder shall quote the offer excluding GST, ESI & PF (Employer’s Contribution). (2) Bidder has to quote their actual cost of the project In INR not in percentage above/below.
Construction of Engineering Hall, Science Laboratory Building and Substation building and related infrastructure at BARC(V) main campus, Atchutapuram, Near Visakhapatnam making fit for occupation all complete on EPC Mode-I turnkey basis
Design and supply of 6 sets of Services drawings (Civil, Electrical, Mechanical, Electronics & IT etc.) in size not less than A1 for all external and internal services for all buildings including Civil, Electrical and Mechanical such as Plumbing systems, water supply distribution systems , drainage systems, sprinklers & irrigation systems for gardens, sewerage systems, rain water collection & disposal systems, waste water pipe lines layout, Internal & External Electrical wiring & Istallations, HT & LT Cabling, LT panels ,HT Panels, PLC panels, APFC/AMF panels, Low voltage services networks, Internet, intranet, HVAC systems, Automatic Fire Alarm systems, Fire Fighting with wet riser System, IP telephony, CCTV system, UPS/Modular UPS, Motorised Rolling shutters, Over Head BUS trunking, Audio Visual Systems, Emergency light exit systems, Substations, Lightining Protection Systems, Passenger and Freight lifts (Elevators), Stand by DG Sets, OFC Cable network, Street lightings, compond lighting, Garden Lightings, Facade lightings, Out door illumination designs, Flood lighting, etc., (The list is just indicative and not exhaustive ) as per the services requirement of each building and as per items specified in the respective BOQ and all other connected services that may be required for successful completion, commissioning & satisfactory functioning of buildings is deemed to be included in this scope of this item of work. No additional payment absolutely whatsoever shall be made on this account. Note: 1) The consultants shall also follow all the norms and regulations specified at various Govt. Publications like NBC 2016 Vol I & Vol II, Structural & Non structural elements for Fire saftey etc. as applicable and based on requirements for establishing & Developing Drawings for all buildings.
Replacement of the AC machines in the chamber no. 07 located at Sesquicentenary Building of Honorable Calcutta High Court.
Supply & Installation of Extra Add-on items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC.