Loading…
Loading…
948 results • Best match
Different urgent electrical repairing work under Banga Bhawan Sub Division, New Delhi..
S & Installation of Extra Add-on Items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle, screws, insulation tape, fasner etc for above AC machines as per direction of EIC.
Operation and Maintenance of water supply Network including Running, Repair and Maintenance of boosting stations, Tubewells, Rising Mains, Distribution Pipeline and Allied water supply works in ward nos, 7, 8, 28, 29, 30 and 32 in Division - 2B under
Horizontal centrifugal pump has 150 hp motor power, optional input voltage 3 phase AC 220V/230V/240V, 380V/400V/415V to 440V/460V/480V and optional input frequency 50Hz/60Hz for sale. A. 150 hp centrifugal pump with maximum flow 140 Lps, maximum head 45m and same diameter of inlet and outlet , can be used for HVAC and refrigeration water circulation, high-rise building pressurized water supply, etc.
PROVN OF CENTRAL AC PLANT CONNECTION IN OT NO-04 AT MH UNDER GE SOUTH PATHANKOT
M & L for CBRI certified 16-gauge Motorised GI fire damper with , at least of 120 minutes fire-rating, spring activated on melting of fusible link having melting point 67.13° C complete with smoke detector / thermistor, fusible link etc. and actuator as required for operation, located in the SA / RA ducts, at all fire rated crossovers (shafts, walls, etc.) along with control panel (located in such a way that the reset may easily be done), interlocked with the building management system for the fire detection or HVAC to trip / close in the event of fire / smoke in the respective zone and tested as per UL-555 complete all as specified and directed. The fire dampers shall meet the following criteria on: [i] Bare fire dampers with 400 mm sleeve [ii] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position [iii] Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers. [iv] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommandations of the manufacturer. (v) Motorized, spring return type, combination fire and smoke damper. (vi) Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.
Condemnation and Replacement of Central AC Plant in MIRC Building at INMAS, Delhi
Design of Central AC Plant including all related drawings / Layout in all complete in consultation with User / CCE and all designs / drawings shall be got vetted by expert HVAC Approved Member of HVAC Society. All designs / drawings shall be submitted to competent Authority for final approval of CCE before the execution of work. Note :- The rate shall be inclusive of all designs / drawings as per site requirement.
DSITC of BMS at DATS
AICMC COST for 8 Years after defect liability period of 2 years:- All inclusive comprehensive maintenance contract for providing experienced electrical /electronics /software engineer for preventive, breakdown and servicing(minimum 4 quarterly visits in a year) of BMS system installed for operation & monitering of HVAC & other associated systems inclusive of low side, CCUs (PACs), SCU, VFD, Fire fighting system , UPS, VRF and lifts remotely as per above BMS SITC works for BMS DATS Complex including providing operation support in general shift by deploying qualified B.Tech engineer having sufficient experience of the BMS system for operation and supervision of these installations complete all as required and specified. Agency have to supply and replace all the faulty spares including controllers, wires,cables panels etc. as per OEM recommendations complete all as required as per specifications.
Supply, Installation, Testing, Commissioning of Air Conditioning arrangement at 2 nos. Meeting Hall, 1 no. Dinning Hall and 1 no. Dignitaries room of Siliguri Mahakuma Parishad, Siliguri.
Supply & fixing of HVAC grade copper pipe with minimum thickness 9 mm Nitril Rubber insulation of following sizes for liquid line and gas line / suction line between ODU and IDU (Make - Ryoku/Nippon):-