Additional Work for the SITC of HVAC and ELV works at Block-IV, Marwad Hospital, Nani Daman.
HVAC - VRV SYSTEM Lifting & Shifting, Supply, Installation, Testing, Commissioning of floor mounted top / side discharge type AC Outdoor unit with Variable refrigerant flow system with required indoor units, refrigerant piping, refnet connection, individual controller, Necessary integrator for BMS with open protocol. The quote for the work should include necessary, lifting charges for mounting the Condensing units with rubber pads, first charge of 410A refrigerant and mounting of indoor units and other accessories. The outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired, tested with all necessary controls. The outdoor unit shall be modular in design and should be allowed for side by side installation. Each modular inverter outdoor shall be having minimum 1 digltal scroll / inverter & 1 fixed scroll compressors , Heat exchanger, condenser fan etc., capable to operate at 3 Phase, 415 +/- 10 % Volts, 50hz power supply. The unit shall be provided with its own microprocessor control panel & electrical compartment with all necessary electrical and control components. Supply of Variable Refrigerant System with all accessories ( Make : DAIKIN ) VRF Out-door Units ( 60 H.P. )
AMC and Servicing of HVAC for Ist ,IInd and IIIrd Floor and 02 Nos DG Set and Panel for Command Control Center Building near mahamaya flyover, Sector-94, Noida
eProcurement System Government of Uttar Pradesh Created By: Ravinder Kumar Created Date/Time: 28-Apr-2026 11:09 AM Tender Title: AMC and Servicing of HVAC for Ist ,IInd and IIIrd Floor and 02 Nos DG Set and Panel for Command Control Center Building near mahamaya flyover, Sector-94, Noida Tender ID: 2026_NOIDA_1134140_1
Overhauling of Supply Fan and Condenser Fan Motors of RS-9/RS-13 of Sidwal Make HVAC.
Request For Submission Of Non-CSR For Electrical, CCTV, DG Set HVAC Work And Fire Fighting Works
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 100 kVA confirming to CPCB-IV plus Emission Compliant with output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f.A.C supply, a totally enclosed liquid cooled multi in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-0. 5 %, with performance class G2 Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters,switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, with suitable capacity DEF tank provided with first filling of oil, diesel tank capacity not less than 230 Litres etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector if necessary. This D.G set is Fitted in Soundproof & Weather Proof Acoustic Enclosure as per CPCB IV plus Emission Compliant (with acoustic enclosure as per latest Government norms) approved Norms.
HVAC Electrical work in Construction of Phase-II of Medical College and Upgradation of Hospital at Nagaur
eProcurement System Government of Rajasthan Created By: Sanjay Kumar Created Date/Time: 09-Jan-2026 07:34 PM Tender Title: HVAC Electrical work in Construction of Phase-II of Medical College and Upgradation of Hospital at Nagaur Tender ID: 2025_RSRDC_523103_1
HVAC work in Construction of CTO Building (RHS Part) under Construction of Mini Secretariat at Sri Ganganagar
Gas charging of VRF/VRV system with R410A refrigerant gas. Before gas charging system shall be flushed with high purity Nitrogen Gas to remove carbon content, dirt particles to make sure that there is no chance of mixing any impurity with Refrigerant Gas. Thereafter System shall be tested with Nitrogen Gas at 1.5 Times of working pressure of R410 Refrigerant Gas to ensure leakproof system. Whole system shall be Vacuumed up to 500-micron level which ensures the zero-moisture content level in piping to ensure better cooling efficiency and long life of the system.