947 results • Best match
Design Supply Installation Testing and Commissioning of HVAC Cooling Towers 3 Nos along with associated Civil Electrical and Piping Works
Design, supply, installation, testing & commissioning of 3 No's CTI Certified Induced Draft Counterflow glass FRP cooling towers guaranteed to cool 785.25 USGPM of water from 97.5 Deg.F to 90 Deg.F at a design wet bulb temperature of 83 Deg.F (with a minimum heat rejection capacity of 786,240 Kcal/Hr.) complete with FRP casing, fill, drift eliminators, fan, fan cylinder, TEFC/TEAO motor (IE3), water distribution system, ladders, handrails, base frame, SS/HDG hardware, along with associated Civil, Electrical and Piping works, complete as per detailed technical specifications and scope of work mentioned in Annexure-XVI of NIT.
SH Replacement of damaged outdated Air handling unit in ICU Conference Hall MS Office and Emergency and Misc HVAC work
SITC of Copper Plate Earthing arrangement for ESD/ANTI STATIC FLOORING at HVAC/ CLEAN ROOM AREA in GOAW Neemuch M.P.
Replacement of 1 X 250 TR centrifugal HVAC plant in ABVIMS building at Dr. RML Hospital, New Delhi. (Electrical Work)
Fabrication /Protection of powerpacks, emergency gate panels, HVAC panels to protect from moisture in Gate Chamber of BHEP-I PH-I
PUF Panel System a. Type: PUF Panel Cottage System, cam-lock jointing arrangement. b. Panel thickness: 60 mm. c. Sheet thickness: 0.5 mm (inner & outer). d. Sheet profile: Both sides ribbed profile. e. Insulation: Polyurethane Foam (PUF), density 40 kg/m³. f. Application: External walls, internal walls (if any), and ceiling of corridor/ roof soffit. g. Finish: Pre-painted (P/P) coating on both sides
SupplyInstallationTesting and Commissioning of HVAC works for vertical extension of OPD building Third Floor at Dr B Borooah Cancer Institute Ghy
Compressor The compressors shall be hermatic type scroll compressor. MOC of compressor shall be forged steel with symmetrical profile. Compressor shall be suitable for continuous operation at 50 Hz, 03 phase, 400 (+/- 10%) Volts ac supply and at RPM near to 2900. Multiple compressors shall be used in single chiller for capacity control as per varying load, also single compressor shall be suitable for operation with varying and fixed frequency. The compressors shall be fitted with crankcase heater for maintaining oil temperature seperately for an individual compressor during shut down and operation period having integral oil seperation system, oil pump and oil sight glass with filter. The compressors shall be suitable for operations with R410A/ CFC free refrigeranthaving suction and discharge side check valve, suction filter, suction discharge side service valve mounted on GI base with vibration isolators with factory fitted sound isolation feature. The compressors shall be direct driven integral hermatic motor and motor shall be suitable for continuous operation. Every compressor shall be having factory provided one year warranty. The compressor's set up shall be inclusive of automatic capacity control with unloaded starting device, high and low pressure cut outs, safety valves, oil pressure gauges. Unloading process shall be done by sensing chilled water outlet temperature with electronic sensors through microprocessor.