Loading…
Loading…
496 results • Best match
Rate Contract for hiring of Temporary Public Address System work on unplanned events under the Jurisdiction of Electric Division-I, PWD, Jaipur.
Optical fiber cable including accessories, connection, testing etc. as required.
Construction of 33 KV Jal Jeevan Mission Bay at 132 KV S/S Narkhi under ETD Firozabad
Supply of Fibre Optical Multimode patch chords (each 10 mtr ) as per sample
Construction of 765/400kV Pooling Substation Mirzapur and 02 nos. 765kV Line Bays at Bara TPS with Line Reactor.
XVII ROAD WORK: - The road work of all nature shall conform to the U.P.,P.W.D. detailed specification No. 20 (Chapter 20) for kankar consolidation, Brick Ballast consolidation, stone ballast consolidation, base course or sub base of bricks, surface dressing with bituminous binders. Laying lean premix macadam (8tcm. thick and 10 em. thick base coat and top coat) Laying Bituminous Macadam (50 mm & 80 mm) thick coat of base coat and base course) Laying Asphaltic concrete (40 mm. and 25 mm. thick), Priming with bituminous primers, established soil layer for road based course, established soil with soft aggregate for road base coats laying bitumen carpet (2 mm. thick) laying gap bitumen concrete seal coat, bituminous penetration Macadam (full grout) Use of pre-coated chip for painting work on road and kankar pitching.
Renovation of Electrical Installations at TCPC (O) Building, Sunder Nagri, Delhi-110093. (SH- Providing EI and Fans, CCTV system, Inverter, RO and Water Cooler System etc.)
Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed,Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value 3.5 18 ps/nm-km and PMD value 0.2 ps/km and Cable Cutoff wavelength 1260 nm i/c splicing & marking etc complete as required. (a) Single Mode 12 Core Optical fiber cable
Carrying out rerouting of 16 inch OD Paradip Hyderabad Pipeline by Horizontal Directional Drilling, Hot Tapping and associated works at ch. 408.10 KM under SERPL Vizag jurisdiction in Andhra Pradesh
Transportation (loading and unloading) of Owner supplied unarmoured Optical fibre cable (OFC) to various sites along Right of Way (ROW), pre laying testing of each cable drum for each fibre and taking the OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer, blowing of OFC through contractor laid HDPE, jointing / splicing of OFC, post installation testing of OFC for each fibre for each drum laid & taking OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer as per the scope, specifications and directions of Engineer-in-charge/ Site Engineer
Development of New Civil enclave at Bagdogra Airport. SH -Construction of Apron, Link Taxiways and airside infrastructure- Provision of GLF System
SITC of OFC Network based Remote Control and indication monitoring PC with suitable software(having lifetime lisence validity) to remotely control ON/OFF, Brilliancy Control, display Feedback indication/Mimic display for Apron High Mast [10 Nos],TaxiwayCkts 2 Nos, Apron Edge light, Stopbar Lights along with integration with existing microprocessor type CCR by provision and configuration of media converter ,network switches, UPS , Power Suppy adapter , PLC , termination of OFC Cable in JBs ,etc as required to complete the work . [ OFC Cable laying excluded in this item ]