Loading…
Loading…
2,333 results • Best match
ELS/Lallaguda: Electrical arrangements for Augmentation of Homing Capacity from 225 to 300 Locomotives.
Erection Total 54000.00 Design, Fabrication,Supply and erection, testing and commissioning of plinth mounted weather proof outdoor type vermin proof, medium voltage 433 Volts, 3 phase, 4 wire system breaker panel with copper bus bar for incoming MCCBs and out going MCCBs confirming to IS 2516 or latest of specified capacities in general confirming to Railway Specification No. B/E.CN/Spec/01. The scope of work includes all civil works foundation bolts mounting channels etc. required as per the conditions . The panel shall be provided with specfied meters, indication lamps, switches MCCBs including CTs, PTS, etc. The panel shall be EPOXY powder coated with SIEMENS grey, The cost also included sign writing, fixing of standard caution boards etc., upto the satisfaction of Engineer at site INCOMING:- 315 Amps 36 KA 4 pole MCCBs -2 Nos. BUS BAR:-600 Amps TP&N Copper Bus Bar - 1Set OUT Item- 09 GOING:-i) 250 Amps 36 KA 4 pole MCCB -2 Nos. ii)100 Amps 4 pole 36 KA MCCB - 2 Nos. iii)63Amps 3 pole 25 KA MCCB -6Nos. iv) 20Amps 2 pole 10 KA MCB -6 Nos. v) 10Amps 1 pole 10 KA MCB -10 Nos vi) 50 KVAR power capacitor -1 No. No METERING:-i) 400 Amps, digital ammeter with Selector Switch -1 Set ii) 0-500 Volts, digital Voltmeter with selector switch -1 Set. iii) Digital kWH meter with RS 485 Port meters CT's of suitable ratio- 1 Set. iv) On, OFF, Two LED indication lamps with individual fuse and control with toggle switches -1set. v) 300A Change over switch-1No. NOTE: 1. All MCCBs fitted with Microprocessor based/electronic release based relays. 2.ICs 100% ICU. All the outgoing MCCBs shall be provided with neutral links and on indication lamps LED and MCCBS feeder details stricking on the panel. S No. Item Description of Item Unit Qty Rate Amount No
Construction of Soladevanahalli Depot
Earth work excavation in Ordinary/hard soil for road work / railway work, minor drains, cable trench etc. Either mechanically or manually as per drawing and technical specification, Including setting out, providing shoring, strutting and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, back filling the excavation earth to the extent required and utilizing/transporting the remaining earth including all leads and lifts including cost of labour, materials and HOM etc., complete.
Rising Main emanating from Thirkanji to 46 nos OHT in Puducherry
For Jacking of 900 mm dia & 10mm thick M.S. Casing Pipe. Installation of product pipe by manual jacking method - Manufacturing, providing, transporting, rolling, lowering, laying & jointing, testing, commissioning of ERW (Electric Resistance Welded), SAW (Submerged Arc Welded) MS pipe (Fe-410 grade) conforming to IS 3589-2001 with latest ammendments including perfect linking welding of joints to correct position including cost and conveyance of pipes and materials with all lead ,lift, cost of labour, loading and unloading of pipes for the following diameters with specified thickness of plate as noted below including bailing out of water wherever necessary for laying of carrier pipe of suitable dia including inside and outside of casing pipe painted with two coats of Anti corrossive tankmastic paint. Installation of steel pipe by Ramming / Jacking method to cross Railway track / NH /BDA /BBMP/Other roads/Existing utilities / NALA crossings, filling the gap between casing pipe and carrier pipe with quarry grit using compressor with all necessary equipments, plants etc, complete. Suitable spacers of HDP/MS or other similar material should be provided in between carrier & casing pipe to prevent carrier pipe forming metallic contact with casing pipe. Note : a. The cost of jacking is inclusive of cost M.S. casing pipe of specified thickness b. The cost of carrying pipe is separate and provision shall be made as per site requirement. The cost of Jacking includes all leads lifts, cost of consumables, fuel charges, labour The cost of jacking and receving pits shall be proposed seperately as per site requirement. For Jacking of 900 mm dia & 10mm thick M.S. Casing Pipe.
Electrification work in connection with Provision of 05 nos. of Lifts at RKM & FTS stations to recoup divyangjans facility in Agra Division.
Design, manufacture, display of wall/hanging/floor mounting type LED illuminated sign/direction boards in various shapes (single & Double sided horizontal & vertical Elliptical/Parabolic full elliptical/half elliptical/half elliptical/Semi Elliptical or other types as per site requirement/flat snigle & double sided wall mounted/ circulating area signage) as per site requirement (decided by Sr.DEE(G)Agra). The display sheet shall be of unbreakable translucent 1 polycarbonate sheet of 2mm to 3mm thickness the text/graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed/routed cut on monogenic calendared vinly of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8W/Sq.Ft and with brightness more than ambient light. Suitable size end cap of 1.5mm thick SS 304 should be provided. (Note:- Signage boards to be provided as per Railway Board Guildlines issued on April-2023 or latest) Square
Agra Cantt.:-Electrification work in connection with Extension of platform no. 01 & 03 to high level for recoupment of shortfall in Minimum Essential Amenities (MEA) at AGC .
supply, erection, Testing & Commissioning of energy efficient LED street light fitting 6 60 Watt outdoor complete street light fitting pressure die cast aluminum (PDC) body with make embossed on PDC body and complete with all accessories/ components and connection with PVC copper wire 2.5sq.mm size multicore and fixing arrangement as per site requirement. The technical parameters will generally conform to relevant Railway specification attached Annexure-II
M.M.G.S.Y. 2026-27 Resurfacing & Strengthening of Various Roads Of Valsad Taluka Dist. Valsad -Total 3 Roads 6.00 Km. (Package No. 8)
Indian Railway Standard Specifications