Loading…
Loading…
2,343 results • Best match
Selection of General Engineering Consultants for Airport connectivity (Phase 2A), Gift City extension (Phase 2B), & Extension from Thaltej Gam to Godhavi (Phase 3A) of Ahmedabad Metro Rail Project
assistance in testing and commissioning of Metro Rail/ Light Rail/ High Speed Rail/ Railways.
BID DOCUMENTS FOR CONSTRUCTION WORK OF C & D WASTE PLANT AND SANITORY LANDFILL FACILITY WITH OPERATION AND MAINTENANCE FOR NADIAD MUNICIPAL CORPORATION.
Purchasing & supplying at site of works, with Railway
CAMC of split type, VRF ducted split unit, cassette type, Tower type, window type & Ductable AC package unit of different capacity in Lumding Division for three years.
Comprehensive Annual Maintenance Contract (CAMC) for operation, routine preventive maintenance, attending breakdowns and ensuring proper functioning of LG make Multi Variable Refrigerant Flow (VRF) Air Conditioning System installed at the Booking Area of Guwahati Railway Station for a period of 03 (three) years. The VRF system comprises 11 Nos. Inverter type Cassette Indoor Units of capacity 4 TR (approx. 5 HP each) and Outdoor Units consisting of 01 No. 24 HP and 02 Nos. 16 HP modules.The contractor shall attend all breakdown complaints on priority basis and restore the system within the stipulated response and rectification time as specified by the Engineer-in-Charge. The CAMC shall be comprehensive in nature and shall include repair, replacement and servicing of all defective parts/components including but not limited to PCB cards, 1 sensors, compressors, fan motors, electronic expansion valves (EEV), contactors, relays, solenoid valves, remote controllers, interconnecting cables, control wiring and all associated accessories required for satisfactory operation of the system. The contractor shall deploy skilled and authorized service personnel having adequate experience in VRF systems. All tools, tackles, testing instruments, consumables, refrigerant gas, lubricants and minor materials required for maintenance shall be included in the scope of work.The scope of work under CAMC shall include operation assistance, periodic inspection, preventive maintenance, servicing, testing, fault diagnosis, attending breakdown complaints and replacement/repair of defective parts for maintaining uninterrupted and efficient functioning of the complete VRF system. Routine maintenance schedules, service records and breakdown history shall be maintained properly and submitted to the Engineer- in-Charge periodically. The work shall be carried out as per OEM recommendations, relevant IS standards and site requirements complete in all respects.
ARC for erection of HT/LT and TC and Maintenance work at Nadiad East & Nadiad West S/dn / anywhere under Kheda District with cost of Nut-Bolt and other low value miscellaneous material required for erection work. under RDSS Scheme
ERECTION STEEL POLES OF 13 METERS FOR RAILWAY CROSSING ON
Work of construction of CWR and Block CWPH at various locations for clusters laying of transfer main from block PS to block CPS rising main from block CPS to Block ESRs, construction of ESRs laying of cluster distribution mains CABP Pck 3 under JJM
Supply and Pushing of MS casing pipe of specified thickness by trenchless method adopting micro-tunnelling or any suitable mechanical technology or technology approved by Railway below ground at all depth under running traffic condition as per railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipment’s for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (upto 3 metre depth) with proper protection at three sites with shoring sheets and ISMB's. Providing MS cutting edges for front shield and Constructing thrust bed at designated level. Necessary de-watering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Railway Authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per requirement and as per approved by railway authorities, specification and the direction of the Engineer. (Protective coating/ lining if done that will be paid extra) Note- 1. Manual Pipe jacking is not permitted for workmen safety reasons. 2. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.
Work for Construction of Water Treatment Plants CWRs and CWPHs Near WTPs Clear Water transmission main From WTP various IPSs Laying of Rising mains to different ESRs Construction of ESRs Distribution system in villages providing FHTCs Including
Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.