Loading…
Loading…
1,281 results • Best match
REPAIR/MAINT OF CERTAIN ROADS AT CENTRAL AMENITIES AREA AND VARIOUS OTM ACCN AREA UNDER GE MISSAMARI
S&F in repairs Solar Light Road studs LED based of size (125x125x25mm) (Model -DA-110-DHRUV of SINOR ) with Aluminium alloy body and Solar powered by nanocrystal solar panel with one high capacity NI-CD Recahrgeable battery and three LED on each side (total six LEDs) fixed with araldite solution /12 mm dia 125 mm long pointed nails complete all as specified and as directed
REPAIR/MAINT OF CERTAIN ROADS AT NORTH OF RLY LINE UNDER GE MISSAMARI
S&F in repairs Solar Light Road studs LED based of size (125x125x25mm) (Model -DA-110-DHRUV of SINOR ) with Aluminium alloy body and Solar powered by nionocrystal solar panel with one high capacity NI-CD Recahrgeable battery and three LED on each side (total six LEDs) fixed with araldite solution /12 mm dia 125 mm long pointed nails complete all as specified and as directed
2. TOURIST DEVELOPMENT OF KALNESHWAR TEMPLE LOCATED IN HARLAKHI BLOCK UNDER MADHUBANI DISTRICT.
Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. (with a 5-year product warranty)
REPAIR TO CERTAIN ROAD AND ROAD FURNITURE AT TECH AND AKASH BIHAR AREA, 274 SU, 756 SU, 12 AFH AT AF STN GORAKHPUR
S&F in replacement solar cat eye aluminium alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25 mm (shank 65mm) of high efficiency mono rystafie solar panel 2.4V/0.3 Watt one NI-ed recharageable battery (1.2V/1600MA) consiting of super bright LED with 10,000 to 18,000 mcd complete all as per manufacturer instructions complete all as specified and directed.
Construction of B type - 4 Units and C type - 4 Units Quarters Ta. Bhiloda Dist. Aravalli.
258 Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar Power Plant with
Supply, installation, testing and commissioning of Telecom material in connection with Provision of CCTV cameras at Manned Non-Interlocked Gates. (41 LC Gates)
Installation, Testing and commissioning of Numbers Solar Power system for power supply for Camera. Fabricated mounting frame of angle iron of suitable size ( MS galvanized ) of adequate strength for Solar panel with suitable fitting arrangement and to be fixed on roof top of Pole. This includes supply of power cable, conduit pipe and grouting bolt/hardware. This includes 1x2.5, 2x2.5 Sqmm cable for series and parallel connection of module and 2x10 sq. mm cable between junction to charge controller, with contractors own material and as per instruction of site engineer. As per technical specification