Loading…
Loading…
1,436 results • Best match
Road Safety Improvement Works for 3 corridors covering 21.80km in Tamil Nadu
Proving and fixing Solar powered Traffic Blinkers of 30cm dia with Polycarbonate Dome 5mm Red of Led 150 Nos. iri each Red Blinkers Light - 1 No. with Red / White / Blue Led Blinkers Delineator Solar Panel : 12v 50w Solar Panel — 1 No. 12v 18 AH Battery -1 No. with Box, Solar Circuit Controller Board Box. Straight Pole : MS Pole 3” dia 2.5mm thick 18 Feet height pole (1 No.) with 2 Feet under ground pole foundation and horizontal pone of same dia,eter with 30cm dia with Polycarbonate Dome 5mm Red of Led 150 Nos. iri each Red Blinkers Light - 1 No. with Red / White / Blue , pole painting including transportation charges, installation charges etc., complete as per standard specification
SH2A Southern Sector of Inner Ring Road SH48C Velachery bypass road SH48 Marmalong bridge Irumbuliyur Vandalur Mudichur Oragadam Walajabad Road Velachery bus stand to Tambaram junction on GST
Proving and fixing Solar powered Traffic Blinkers of 30cm dia with Polycarbonate Dome 5mm Red of Led 150 Nos. iri each Red Blinkers Light - 1 No. with Red / White / Blue Led Blinkers Delineator Solar Panel : 12v 50w Solar Panel — 1 No. 12v 18 AH Battery -1 No. with Box, Solar Circuit Controller Board Box. Straight Pole : MS Pole 3” dia 2.5mm thick 18 Feet height pole (1 No.) with 2 Feet under ground pole foundation, pole painting including transportationcharges, installation charges etc., complete as per standard specification. SH 2A
Installation of a solar water tower in front of Kajal Mandal house in Sangamahul village under Bhurkundabari Panchayat
Provision & Installation of Solar Powered submersible Auto run & Stop DC Pump Motor (900 Wp)of stainless steel suitable for minimum 125mmx115mm bore well operating head 60.00m discharge rate minimum 2000 LPH with lowering up to 57.00m suitable dia HDPE pipe &2.5sq mm x3core flat submersible cable of IS694:1190 including monol /Poly Crystalline PVC array (900WP) mounted on steel structure for storage water tank (5.00mhigh)in a suitable direction to optimize panel uses and withstand the wind pressure up to 200 Km /hour &making suitable arrangements to operated Hand pump manually in the same bore when there is no solar power including 5 years warranty against defects in materials and workmanship with locking arrangement of switch board . the system should be ECO-friendly. (a)The PVC Modules should be mounted on hot dip galvanized metallic structure of adequate strength &appropriate design. (b)Components &parts used in the solar pumping system including the metallic structure (MS)should confirm to the BIS (c)The rates are pumping system includes compressive maintenance contract for 5 years . During CMC period the contractor has to visit the installation on quality basis and also on intimation of Defect from user . During CMC Contractor shall have to repair /replace the parts found defective due to manufacturing defect free of cost. (d)Max-m shut off head 120.00meter. (e)Discharge 5000liters per day for 90.00m Dynamic head (f)Cable 2.5mmx3core as per IS 694 (g)Control panel suitable for above pumpset with arrangement of dry run protection ,sensor, float switch &rain preventive box etc. (h)Lighting arrestor. (i)Controller for censer for over flow and dry bore.
Installation of a water tower at the hand pump in Simuldan under Kaliasol Panchayat
Provision & Installation of Solar Powered submersible Auto run & Stop DC Pump Motor (900 Wp)of stainless steel suitable for minimum 125mmx115mm bore well operating head 60.00m discharge rate minimum 2000 LPH with lowering up to 57.00m suitable dia HDPE pipe &2.5sq mm x3core flat submersible cable of IS694:1190 including monol /Poly Crystalline PVC array (900WP) mounted on steel structure for storage water tank (5.00mhigh)in a suitable direction to optimize panel uses and withstand the wind pressure up to 200 Km /hour &making suitable arrangements to operated Hand pump manually in the same bore when there is no solar power including 5 years warranty against defects in materials and workmanship with locking arrangement of switch board . the system should be ECO-friendly. (a)The PVC Modules should be mounted on hot dip galvanized metallic structure of adequate strength &appropriate design. (b)Components &parts used in the solar pumping system including the metallic structure (MS)should confirm to the BIS (c)The rates are pumping system includes compressive maintenance contract for 5 years . During CMC period the contractor has to visit the installation on quality basis and also on intimation of Defect from user . During CMC Contractor shall have to repair /replace the parts found defective due to manufacturing defect free of cost. (d)Max-m shut off head 120.00meter. (e)Discharge 5000liters per day for 90.00m Dynamic head (f)Cable 2.5mmx3core as per IS 694 (g)Control panel suitable for above pumpset with arrangement of dry run protection ,sensor, float switch &rain preventive box etc. (h)Lighting arrestor. (i)Controller for censer for over flow and dry bore.
Rate Contract for Supply Installation Commissioning of CCTV Surveillance Cameras
185 CF – CCTV COMPONENTS 26CF58 Supplying, Installation, Testing & Commissioning of : Solar Power Solution for Camera • Solar Panel with Mount bracket + Battery + Solar Inverter with 20 hrs backup system + IP67 Enclosure for battery & invertor with pole mount bracket
Infrastructure Development of Ranipur Jharial at Bangomunda Block, Bolangir Part 2
Supply of Elegant look 60 W(>=190lm/W) AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 96 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=11400 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products. 1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 – MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 – EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light ) Make-(Philips/Panasonict/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect.