Loading…
Loading…
1,441 results • Best match
SPL REPAIR/ REPLACEMENT OF CEILING FANS AND PROVN OF GEYSERS, WATER COOLER, DESERT COOLER, AC, SECURITY LIGHT, WALL FAN AND OTHER SANCTIONED WORKS UNDER AGE E/M AT NAMS (4th Call)
Supply and fixing rotational moulded polyethylene water storage tank of 1000 ltr capacity (cylinderical vertical with closed top) Triple layer Food grade hoisted and fixed in position, kept over the height of hot water tank of solar water heater on MS angle iron frame of size 35mm x 35mm x 5mm duly grouted in PCC 1:3:6, complete all as specified and directed. Note: Cost of MS angle iron frame and PCC work shall be measured and paid separtely uder relvant item of the contract.
demarcation of the raw water gravity main by supplying and erecting reinforced cement concrete (RCC) poles at required intervals on both sides of the alignment within the Water Authority acquired land for permanent identification
OD152941/2025-2026:TANKSONAR-WIFI-VER1.0 Solar-powered, WiFi based, ultrasonic echo-based realtime water levels monitoring and alerting system. Ultrasonic echo-based non-contact water level sensing at centimeter accuracy. Supports tanks upto 20m deep. Lower level and upper-level configurable thresholds over web app, and mobile app. Lower and upper-level threshold alerts over web app, and mobile app. Solar-powered with in-built 3.3Ah Li-FeSO4 battery. In-app tank water level trend graphs and analytics. Can be paired with pumps at any distance from the tank over internet for automatic pumping based on remotely configurable tank water level thresholds. Additional weather-proofing enclosure included. On-site warranty: 5 years
CONSTRUCTION OF LNG SATELLITE STATION WITH LNG DISPENSING FACILITY AT BADAPOKHARIA, TANGI -KHORDA, CUTTACK (PART-A), NASIRABAD, RAJASTHAN (PART-B), RAMAYAMPET, MEDAK TELANGANA (PART-C) AND ARPL, PUNE- AHILYANAGR, MAHARASHTRA (PART-D)
Design, Engineering, Manufacturing, Supply, Installation and commissioning (including packaging and forwarding, insurance, handling and unloading as elaborated in tender and elsewhere) of Diesel engine driven Horizontal Split Casing Centrifugal pumping set with bronze impeller with C.I. Body and pump accessories complete and connected by a flexible coupling to a water cooled diesel engine (Conforming to IS : 10002) mounted on a common structural base plate with anti- vibration pads and foundation complete with AMF panel, battery (including one spare battery) battery charging, cooling system, fuel tank, fuel system, automatic starting arrangement, exhaust pipe of required length to discharge at suitable height with muffler to meet latest environmental norms, day oil tank (storage of 8 hrs. running capacity) mounted on suitable structural supports, matching flanges (conforming to IS:6392 table - 17), SS bolts, nuts, gaskets, common base plate, flexible coupling, coupling guard, power and control cable, consumables, compulsory erection & commissioning spares, first fill of lubricants, fuels, Special Tools Tackles etc., Configuration, Interfacing, erection at site, Integrated Testing & Commissioning as per Job specifications and Special Instructions enclosed. The main pump shall be started automatically through a pressure transmitter and stopped manually. Provision of signal output to control room shall be there in the pump panel to be installed in pump house. The work shall be carried out as per direction of Engineer in Charge. Capacity of Pump : 75 m3/hr. Head : 80 mwc Engine BHP : Suitable size to be furnished by the bidder with sizing calculation.
Performance Based Maintenance Contract from Km 58.125 to Km 93.68 on NH373 Hassan Tanniruhalla Holenarasipura town pertaining to Executive Engineer National Highway Division Hassan in the state of Karnataka
Solar Raised Pavement Markers Supplying & fixing of Solar Raised Pavement Markers made of polycarbonate molded body with circular shape, solar powered, LED self-illumination in active mode, 360 degree illumination and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode. The marker shall support a load of 20000 kg tested in accordance to ASTM D 4280. The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand temperatures in the range of 0 C to 70 C. Color of lighting could be provided in red or yellow (amber) as per requirement and typical frequency of blinking is 1 Hz. There should be current losses of less than 20 microamperes at 2.4 V in sleepcharging mode to enhance the life of the marker and a full charge should provide for a minimum autonomy of 50. The height, width and length of the marker shall not be less than 10 mm x 100 mm x 100 mm. Also, the surface diameter of the marker shall not be less than 100 mm respectively. The weight of the marker shall not exceed 0.5 kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the Engineer Solar Powered Road Markers are more effective which can immediately draw the attention of drivers and shall be provided at locations like approach to road crash prone |locations and highly hazardous locations like bridge, toll plaza, sharp curves, pedestrian crossing, lane transition, speed humps, junctions, channelizers, construction sites, rail road crossings, accident prone locations, median opening and lane changing where performance of normal road studs are not that effective due to street lightings and other roadside activities. etc., as per specification and as directed by the Engineer incharge of work.
DEVELOPMENT OF TOURIST FACILITIES AT SONEPUR MELA GROUND, SARAN IN BIHAR.
NS-14 Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power
Climate Resilient Coastal Fishermen village at Tamliporia, Purba Mukundapur Maa Naikali Matsya Khuti, Ramnagar-I Dev. Block, Purba Medinipur District.
B) Stand Alone Solar PV STREET LIGHTING SYSTEM: Configuration-I Stand Alone Solar PV STREET LIGHTING SYSTEM (12W LED LIGHT) a) 6 METER G.I. POLE b) 1 x 75 Wp Si PV Module. c) 1 x 30 Ah 12.8V Lithium Ferro Phosphate (LiFePo4) Battery d) 1 x 12 LED Luminary