Loading…
Loading…
3,946 results • Best match
Construction of Double Storey Office Building for TLMD 1st and TLMD 6th at Bemina
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy>135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light/ street light with bracket of suitable size, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with inimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).), Philips/ Wipro/ Regent/Endo/LT make / sample to be approved before installation..
Construction of control room with development work, parking, store shed, fencing work, water supply system and water harvesting system at 132 KV GSS Chandpura, Sikar
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing and secondary lens on each LED/ integrated lens diffuser without cover & should be High power LED of 3 to 5 watt each . The System efficacy >=135 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current 750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required.LED Street Light fixture with Minimum lumen output 8100 lm. Code-18.12.4
Renovation Work of Steel Ganj Talab in Nagar Palika Parishad, Bahraich
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect. CAT- AAA
Tourist Reception Centre for Integrated Development of Deomali in Koraput District
Supply of Elegant look 60 W(>=190lm/W) AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by concerned engineer from OTDC before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 96 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by concerned engineer from OTDC before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=11400 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from concerned engineer from OTDC for the technical acceptance of the products. 1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 – MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 – EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light ) Make-(Philips/Panasonict/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect.
Development of Proactive 2.0 street in Srirangapatna TMC Limit
Supply of LED Street light luminaire with pressure diecast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antiglare clear diffuser with injection moulded polyca...
i) Electrical work in c/w "Construction of subway in lieu of LC gate no 8/spl at Km 286/5-6 in bet stn GGA-LLM in SBG-BGP section of Malda Division." ii) Electrical work in c/w "Construction of Subway in lieu of LC gate no 2A at Km 314/9-315/0 bet stn NAT-AKN in BGP-JMP section of Malda Division." iii) Electrical work in c/w "Construction of subway in lieu of LC gate no 2 at Km 316/7-8 in bet stn NAT-AKN in BGP-JMP section of Malda Division." iv) Electrical work in c/w "Construction of subway in lieu of LC gate no 7 at Km 325.636 in bet stn AKN-SGG in BGP-JMP section of Malda Division." v) Electrical work in c/w "Construction of subway in lieu of LC gate no 11 at Km 331.629 in bet stn SGG-GNNA in BGP-JMP section of Malda Division." vi) Electrical work in c/w "Construction of subway in lieu of LC gate no 16 at Km 351/8-9 in RPUR yard in BGP-JMP section of Malda Division." vii) Electrical work in c/w "Construction of subway in lieu of LC gate no 16/spl at Km 361/6-7 in bet stn JMP-DRTP in BGP-JMP section of Malda Division." viii) Electrical work in c/w "Construction of subway in lieu of LC gate no 17/spl at Km 362/7-8 in bet stn JMP- DRTP in JMP-KEU section of Malda Division." ix) Electrical work in c/w "Construction of subway in lieu of LC gate no 23 at Km 377/9-378/0 in bet stn MSDN-AHA in JMP- KEU section of Malda Division." x) Electrical work in c/w "Construction of subway in lieu of LC gate no 26 at Km 382/6-7 in bet stn AHA-KJH in JMP-KEU section of Malda Division." xi) Electrical work in c/w "Construction of subway in lieu of LC gate no 27/spl at Km 386/4-5 in bet stn AHA-KJH in JMP-KEU section of Malda Division." xii) Electrical work in c/w "Construction of subway in lieu of LC gate no 34/spl at Km 400/0-1 in bet stn DNRE-KEU in JMP-KEU section of Malda Division." xiii) Electrical work in c/w "Construction of subway in lieu of LC gate no 29 at Km 41/14-15 in bet stn BHLB-PJLE in BGP-MDLE section of Malda Division."
26 26 Supply, fixing and connection of LED street light Numbers 16.00 4105.61 65689.76