Loading…
Loading…
593 results • Best match
Provision of 3 phase supply to proposed 2x25 kV TSS at Badnera i.e. (A) Supply & erection of EHV equipments for proposed 3rd phase of TSS-I & II bay at 220 kV Badnera S/Stn under EHV O&M Division, Amravati. (B) Stringing of 3rd phase for existing 220 ... Maint. Sub Division ...
2 2 Collecting the metal from switchyard , cum 38.00 677.00 25726.00
AMRUT- KLM SS-01 -Zone A1 - Iron Bridge Zone Commissioning of sewerage system and Rehabilitation of Existing sewerage system, extension of the sewerage systems and construction of Pumping station and wet well at Iron bridge zone - Sewerage work
OD272416/2025-2026:IRON BRIDGE:- ELECTRICAL PANELS AND TRANSFORMERS (H.T Supply)<br><br>Supply and delivery of 400 KVA/11KV/433 V,50Hz,3 phase,Dyn11,ONAN cooled out door type transformer (Copper wound) for the total working load of pumpsets with initial filling of oil interlocking arrangements and all fittings as per standard.<br>Fabrication and supply of 11KV/4 pole structure with suitable RS JOIST along with all structure materials and supplying and fitting suitable size transformer bus bars ,lightning arresters ,drop out fuses AB switch(400A) etc complete required for substation of transformers as per IE rules and approved by CEIG drawing.<br>Construction of transformer plinth<br>Designing and preparation of CEIG drawing approval of safety certificate including submission of completion report,rectification report etc<br>5 Nos of pipe Earthing in the the transformer station and all electrical equipments as per IE rules including cost of materials<br>Chain link fencing the transformer yard with suitable size RSJ along with all structure materials and spreading metal in the transformer yard with suitable size curbe wall as per standard<br>Erection of transformer in sub station as per IE rules .<br>Supply, Delivery of Trivector meter CT/PT unit, cables etc and fixing of kiosk for accommodatin TOD meters(DLMS) as directed by EB engineers including the fencing the E.B structure etc complete.<br>Supply and delivery of floor mounting type MV control panel of vermin proof, dust proof, modular type consisting of the following accessories and controls. The control panel shall be of enclosed type and built with compartmentalized modular type cubicle. All cubicle shall be constructed from 14 SWG, M.S sheet at the bottom and rear and 12 SWG M.S Sheet at front. The panel board shall have removable rear cover hinged front door fitted with knobs. The interior and exterior of the panels and compartment shall be treated with one coat of primer and two coats of stove enameled light gray shade suitable for electric applications. The panel should be supplied with 4 nos of copper bus bars of current carrying capacity properly sleeved(heat srinkable) with respective colour codes.<br>Incoming <br>1.630A 4pole MCCB with Breaking capacity 25 / 36KA for<br> controlling the Transformer (&) DG Set with interlocking(connections are through suitable contactors) <br> arrangement - 3 nos<br>2. (0-500 v) Voltmeter (w) selector switch -1set<br>3. Ammeter 0- 600 A capacity (w) phase selector switch – 1 set<br>4. 3 phase / 4 wire KWH meter – 1 no<br>5. Earth fault relay – 1 set<br>6. Slide locking type fuses – 1set<br>Outgoing<br> <br>1. 63 A TPN MCCB for lighting control –1no<br>N.B (a) Necessary CTs should be provided for safe guarding the instruments wherever necessary<br>(b) The supply should be terminated through A.M.F panel of Genset offered for Auto startup the plant and equipment<br>opration during EB power failure with in 15 secs<br>Providing rules<br>Lighting<br>Supply and completion of required house wiring for accommodating the following including DB panels, cost of wire, cost of PVC conduits, earthing etc.<br>1. SV lamp to be fixed on the top of control room -1no (250w)<br>2. Industrial type tube lights inside the control room.-8 nos (40w)<br>3. 4 Nos CFL (not exceeding 25 W) at suitable locations with fittings.<br>4. 15 A plug and socket with control switch – 2 nos<br>5. 5 A plug and socket with control switch – 2 nos<br>6. Portable lamp with 25W CFL bulb and 15 M cable<br>7. Pedestal fan -1 no<br>The above electrical items as per IE rules includes cost of materials such as bulbs and fittings etc.<br><br>Erecting, commissioning and testing
Implementation of Micro Irrigation System (Drip Irrigation System) of at Droneshwar Pick Up Weir of Machhundri Irrigation Scheme At-Village Dron, Taluka Gir Gadhada, District Gir Somnath.
Switchyard area equipments including
As per TD
Providing, installation, testing and commissioning of LT MCC with panels housing motor starters relays, MCB/MCCBs, bus-bar for all pump sets including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications .
Tender for Work of Mechanical Strengthening and Stub strengthening and H-Frame replacement work of 66Kv Sardargadh - Manavadar Tap at Bantwa H-Frame Line under R and M 2026-27 With Buyback of OLM under Manavadar AM Division of Junagadh Circle
switchyard, “permit to allow to work” must be isolated /de-energized and written clearance should
Tender for Work of Mechanical Strengthening and Stub strengthening of 66Kv Sardargadh - Dungari and 66Kv Dungari - Bantiya H-Frame Line under R and M 2026-27 With Buyback of OLM under Manavadar AM Division of Junagadh Circle
switchyard, “permit to allow to work” must be isolated /de-energized and written clearance should