Loading…
Loading…
93,191 results • Best match
INTERCEPTION AND DIVERSION WORK FOR TAPPING NALLAH AND SETUP SEWAGE TREATMENT PLANT FOR USED WATER MANAGEMENT FOR GAIRATGANJ TOWN
INTERCEPTION & DIVERSION WORK FOR TAPPING NALLAH AND SETUP SEWAGE TREATMENT PLANT FOR USED WATER MANAGEMENT FOR GAIRATGANJ TOWN
Custom Bid for Services - Hiring of services of four nos of Effluent Treatment plants Similar Category Operation and Maintenance of Effluent/Sewage Treatment Plant
Custom Bid for Services - Hiring of services of four nos of Effluent Treatment plants Similar Category Operation and Maintenance of Effluent/Sewage Treatment Plant
MAINTENANCE AND IMPROVEMENT OF SEWAGE TREATMENT PLANT TERTIARY TREATED WATER NETWORK AND SEWAGE PUMP HOUSE DG SET AT MIL STN GANDHINAGAR
Supply and laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable all as specified.
Providing Grid Connected Roof Top Solar Power Plant without Battery Bank in Sewage Treatment Plant and Water Work at Jind.
32.70.2 Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 2. Above 10 kWp and up to 100 Kwp [Through Rate]
Krishna Koyna Lift Irrigation Project- Mhaisal Lift Irrigation Scheme- Kavathemahankal Part- Construction of Arag Bedag Lift Irrigation Scheme Tal. Miraj Dist. Sangli and Borgaon Lift irrigation Scheme Tal. Kavathemahankal Dist. Sangli
eProcurement System Government of Maharashtra Created By: ROHIT KORE Created Date/Time: 17-Feb-2026 11:39 AM Tender Title: Krishna Koyna Lift Irrigation Project- Mhaisal Lift Irrigation Scheme- Kavathemahankal Part- Construction of Arag Bedag Lift Irrigation Scheme Tal. Miraj Dist. Sangli and Borgaon Lift irrigation Scheme Tal. Kavathemahankal Dist. Sangli Tender ID: 2025_CWRDP_1253604_1
REPAIR MAINT TO CHAJJA ROOF SUNKEN FLOOR TREATMENT INTERNAL WATER SUPPLY PLUMBING WORK FLOORING KITCHEN HARDWARE PAINTING AND OTHER MISC B R WORKS AT AFTC 2DC AREA AND AFS JALAHALLI
Petty repair to internal/external water inlet water pipe line coming from over head tank to the quarter including socket,elbow,nipple ,with repair to water blockage , pipe line leakage, cleaning internally , removing the blockage including concealed water tubing etc of any height using scaffolding and and making the water supply functional complete all as specified and directed.