Loading…
Loading…
3,755 results • Best match
AGRA EXPRESS-WAY PAR LUCKNOW SHAHAR ME AAGMAN HETU PRAVESH DWAR KA NIRMAN VIKAS KARYA. (KRISHNA DWAR)
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage., For vertical surface two coats @ 0.70 kg per sqm
CERTAIN B/R REPAIRS MAINTENANCE FOR LEAKAGE ARRESTING WORKS IN STATIC WATER TANKS OHT FIREFIGHTING TANKS AND OTHER CONNECTED WORKS AT NAD NAUSENABAUGH AND NAVAL BASE AND CONNECTED WITH CERTAIN WATER SUPPLY WORKS UNDER GE U II VISAKHAPATNAM
M & L for providing two coats of water based epoxy coating certified for portable water [Sikagard 67 of SIKA/ Nitokote EP 405 of FOSROC/ T Grout EC 200 of THERMAX/ Tankmastic of STP or equivalent chemical as specified herein after in Particular Specifications] on all over the internal reinforced cement concrete surfaces of water tanks complete all as per manufacturer's instructructions, as specified and as directed. [Note: The Thickness after two coating shall not be less than 500 microns. The coating shall be applied using brush. First Coat shall be allowed to dry for 6 to 8 hours and then second coat shall be applied and allow it to cure complete 24 hrs.]
Construction of Culvert Admin building and Overhead Tank Under Ground Sump and Formation of Road at KINFRA Industrial Park Puzhakkal Thrissur
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerincharge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
Under The BP Year 2026 27 Work of Regrouping by installing new transformers at various place Under the area of EDSD Mandiyanhu Newadiya Barshathi and Rampur Under EDD Badlapur Jaunpur
STAY CLAMP 8.5M STP POLE
Running Contract for Maintenance of Line damaged due to Aandhi/Tufan/Accident/Other Special Reasons under EDD-Baheri
STP 9 Mtr Long
Custom Bid for Services - GROUND WATER ANALYSIS for more detail refer scope of job, boq, and tender document, Custom Bid for Services - DRINKING WATER SAMPLE TEST for more detail refer scope of job, Custom Bid for Services - TESTING OF AMBIENT NOISE ... ETP/ STP WATER ... ETP/STP WATER TESTING ... of Water Quality ... of Water Quality ... to Plant Air ... to Plant Testing ... of Water Quality ... to Plant Testing ... of Water Quality ... to Plant Testing ... of Water Quality
Custom Bid for Services - ETP/STP WATER TESTING for more detail refer scope of job