Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹2.5 L
Closing Date
24 Sept 2026, 5:00 pm
Superintending Engineer
Superintending Engineer, Uttarakhand Jal Sansthan, Pithoragarh
Permanent Restoration Work of Damaged Restoration work damaged pipe line and protection work under Kapkot (Anarsa, Manigair, Baisani, Pausari and Sumati) W/S Scheme
2026_UKJS_99505_1
391/Nivida/2026-27/16 dated 22.08.2026
Open Tender
Civil Works - Water Works
Item Wise
180 days
Bageshwar
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,720
Executive Engineer, UJS
₹2.5 L
Pithoragarh
27 Aug 2026
27 Aug 2026
25 Sept 2026
27 Aug 2026
24 Sept 2026
8 Sept 2026
1 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Rates of Restoration work of Dameged Pipe line & Protection work under (Anarsa, Mainigair, Baisani, Pousari & Sumti) W/S Scheme | |||||
| 1.01 | Anarsa Water Supply Scheme | - | - | - | - |
| 1.02 | Providing of all materials , Carting from site store to site of work, Laying & Jointing of GI screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etc complete
50 mm dia | 1,100 | Rmt | - | - |
| 1.03 | 65 mm dia | 400 | Rmt | - | - |
| 1.04 | Source Work | - | - | - | - |
| 1.05 | Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical
specifications Clause 305.1 of MORD Specifiction | 8.25 | cum | - | - |
| 1.06 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (For height upto 5 m) R.C.C grade M 20 | 3.6 | cum | - | - |
| 1.07 | Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 (The reinforcement steel shall be procured from original (primary) steel producers as per clause no. 2011.3.1 of MORD specifications (First revision'2014) and IS 1786:2008 clause no. 1.6) | 7.07 | Qtl | - | - |
| 1.08 | Construction of SCC Cum Roughning Filter As per unit Estimate | 1 | Job | - | - |
| 1.09 | Pipeline work | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
Anarsa.pdf
Tender Documents • 3.58 MB
BOQ_117338.xls
BOQ • 0.44 MB
TS.pdf
PDF • 1.38 MB
ESMP.pdf
PDF • 0.86 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .