Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.6 LAccepted-AOC 1001 SHIVALIK ABAISE 100 FEET ROAD OPP ANANDNAGAR APARTMENT PRAHALADNAGAR AHMEDABAD AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹62.2 L+₹54,630 (0.89%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹62.9 L+₹1.2 L (2.00%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹63.3 L+₹1.7 L (2.73%)Rejected-Finance 241 SWAMI NARAYAN NAGAR 1 OPP SWAMIVIVEKANA ASHRAM BEHIND HALAR HOUSE JAMNAGAR JAMNAGAR GUJARAT 361001 | JAMNAGAR | GUJARAT | 361001 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹63.9 L+₹2.3 L (3.67%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L5 | Rejected-Finance Being L5 |
Tender Value
₹74.3 L
EMD Value
₹1.5 L
Closing Date
10 Aug 2020, 6:00 pmClosed
Sr.Manager(E-E)
Sr.Manager (E-E), Airports Authority Of India, Regional Head Quarter, Western region, Operational office building, 5th floor, Parsiwada, Vile Parle (East), Mumbai-400099
As Per Tender Documents
2020_AAI_47717_1
AAI/ENG/WR/SM/BHU/NIT-02/20-21
Open Tender
Repair and Maintenance Services
Item Rate
730 days
Bhuj Airport
Tender Fee, EMD, Un-conditional acceptance letter and all other pre qualification documents as per Tender Documents
2 documents required · 2 mandatory
₹1,120
Yes
Airports Authority of India
₹1.5 L
Yes
31 Aug 2020
27 Jul 2020
17 Aug 2020
28 Jul 2020
10 Aug 2020
28 Jul 2020
28 Jul 2020 - 7 Aug 2020
Amount
Annual Operantion and Maintenance of Electrical & Mechanical Installations of Terminal building,Operational area, City Side, AAI residential Colony, Power House, Pump House and other anceliary building of Bhuj Airport including Operation & Maintenance of Pumps, DG Sets, Conveyors in three shifts on all working days as per specification & condition attached, attending to complaints/ faults/ breakdowns, ensuring serviceability and satisfactory working condition of the system, performing preventive maintenance, maintenance of records/ documentation etc. as per the detailed specifications, terms & conditions covered under this contract, on all days including Sundays and holidays and also as & when required basis etc. as required.
Inspection, servicing and Testing of following Electrical Installations and performing preventive maintenance checks and submission of reports to AAI. For VCB and ACB, the activities shall be carried out through the authorized service dealer of the OEM. For power transformer, the activities shall be carried out through OEM/authorized service dealer of OEM or any specialized/licensed agencies with suitable experience for the work.
11 KV VCB (Make: Crompton Greaves, Model: 12V X 12 XL, Rating: 400 A)
Current Transformer of VCB (a set of three) ( Rating: 60-30/5+5A,15 VA/CL.1.0/5P10)
11 KV Potential Transformer ( Rating 11000 /110 V, 100 VA/CL 1.0)
Distribution Transformer 11KV/433V, 500KVA ( Make: Crompton Greaves)
Air Circuit Breaker 800 Amp,400 V ( Make: L & T, Model: CN-CS 800
Inspection, servicing, calibration and testing of Electrical metering and safety device, performing relay co-ordination of the relays, including submission of reports on the related calculations for relay setting etc. as required. The activity shall be carried out through specialized agencies/licensed agencies with appropriate licenses and experiences. (A) IDMT relays (2OC & EF) - 7 nos and Auxiliary and tripping relays (Type-VAA21Z98501FCH)-4 Nos. ( Details as per tender Document)
Dehydration and filtration of transformer oil including testing the BDV and acidity before and after testing and submission of test reports , replacement of Silica Gel etc. as required for following Transformers - 500 KVA Transformer (App. 420Ltr.)
Supply of tested transformer oil for toping up the transformer as required.
Rewinding of the 3 phase 50 Hz AC Electric motor of following Capacity pumps :-
Monobloc pumps below & up to 5 HP capacity
Submersible pump up to 5 HP
Monobloc pumps above 5 HP & up to 7.5 HP capacity
Spray painting of sheet metal enclosures/LT panels/Feeder Pillars/DG exhaust pipes/ Control panel with two coats of synthetic/enamel paint of grey or any other colour as approved by AAI, including cleaning the surface , rewriting the identification of the circuit. The electrical accessories shall be covered and protected from dust during painting as required.
Decoration of Terminal building, Main Entry Gate facia with LED serial lighting and RGB pattern lighting on special occassions/nationally important days/festivals as per the requirements shown below. (a) Minimum no. of LED serial lighting - not less than 6500 LED lights. (b) RGB pattern lighting for pillars of terminal building 15 Nos. ( RGB PAR lights shall be used) (c) Pixel Chaser light batten ( with minimum 12 colour combinations) running linearly on the top of the building for a length of not more than 200 m.
Independence day ( Starting from 18.00 hrs on day before independence day to 06.00 hrs on the day after independence day) Each occasion in an year shall be treated as one JOB.
Diwali ( Four days - Starting from 18.00 hrs. on day before Diwali, Diwali day, Gujarati New year day and Bhai dhooj day , till 06.00 hrs on day after Bhai dhooj day) Each occasion in an year shall be treated as one JOB.
Republic day ( Starting from 18.00 hrs on day before republic day to 06.00 hrs on the day after republic day) Each occasion in an year shall be treated as one JOB.
AAI foundation day ( Starting from 18.00 hrs on day before foundation day to 06.00 hrs on the day after foundation day)
Painting of street light poles, arms with aluminium paint of ( 2 coats) of approved brand and manufacturer, along with one coat of primer, inlcuding cleaning the surface as required.
Pole with single arm (Height not more than 9 m) - City Side & Staff Colony
Pole with single arm (Height not more than 7 m) - Perimeter
Pole with two arms (Height not more than 9 m) - City Side & Staff Colony
Pole of LED post top lantern fixture of height not more than 2.5 metre and dia not more than 18 cm dia.
Painting of HT structure including fencing ( Approximate 6 Sq.mtr.), with two coats of aluminium /enamel paint including cleaning, scraping and applying approved steel primer where ever required similar to the existing colours and shade complete as required.
Supply of batteries for DG set cranking with minimum 2 years warranty:12 V, 180 Ah lead acid battery
Execution of Complete items of CPWD Delhi schedule of rates (E&M) 2018.[Up to a Ceiling limit of Rs. 80,000 without GST]. The materials used for executing the DSR items shall be as per the approved make list of AAI, as enclosed with the tender document.
Onix Structure Private Limited
S. N ELECTRICALS
Ascent Electrification Engineers
Manish Electricals
Techno Electricals
PAN POLAR ENGINEERS PVT. LTD.
SAURABH ENTERPRISES
Adarsh electric works
JAYRAM INDUSTRIES INDIA PRIVATE LIMITED
ABHISHEK ASSOCIATES
Freaquer Corporation Private Limited
SHAH ASSOCIATES
Metropolitan Infrabuild Development And Services Pvt Ltd
M/s K.N.Construction
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .