VIJAYAWADA MUNICIPAL CORPORATION
Vijayawada
Providing Electrification work and Installation of New Air Conditioners at Circle III Revenue Office and Cash Counter in Circle III area
941272
Tender Notice No.: 09/VMC/CDB/2026-27, Rc.E3-109683/2026
OPEN - NCB
Similar Work
NTR
5 documents required · 5 mandatory
₹150
₹4,300
29 May 2026
29 May 2026
29 May 2026
Supply of 1.8/1.9/2.0TR, 3 Star capable of delivering not less than 21600 BTU/hr and above with operating on refrigerant R-410A / R-32, INVERTER Model Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidation with copper condenser. Makes: Mitsubishi / O General / Toshiba (prevailing models in the market) as directed by the departamental authorities.
Supply of 3 core 2.5 Sqmm PVC insulated and sheathed FRLS/FRLS-H copper round cable for voltage up to 1100V as per IS 694/1990. Makes: Finolex / Polycab / Goldmedal / Finecab as per the approval of the departmental authorities.
Supply of 5.0 KVA 1-Phase, automatic Electronic Voltage Stabilizer. Makes: V-Guard / Real Guard / Uni Stab / ITL /Power Guard including labour charges conveyance of all materials as per site condition and as directed by the departmental authorities.
Supply of 6-32A SP MCB10KA C/D Curve ISI Mark of Makes: Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4/ Havells STADx /L&T-AU/Indo Asian-Opti pro/ HPL (Techno) as directed by the departamental authorities.
Installation of Split Air Conditioners, with all charges including cost and conveyance of all materials and labour charges etc., complete as directed by the departmental authorities
Providing 2 runs of Copper tubes for suction and liquid between indoor and outdoor unit for split/Casseete Air- Conditioner including foaming etc., complete. Make: Copper:Totaline /Nippon /Mandev. Nitrile Insulation: Kflex/ Totaline /Armaflex 5/8" x 1/4" as directed by the departamental authorities.
Supply and run of 2 of 56/0.3mm (4 Sq.mm) FR P.V.C. insulated flexible copper cable in existing pipe for mains inlcuding all labour charges etc., complete as directed by the departamental authorities using Finolex/ RR kabel/ Havells KEI/ Polycab/ Gloster/ Goldmedal /GM make wire.
Supply and run of 1 of 14 /0.3mm (1.0 Sq.mm) FR P.V.C. insulated flexible copper cable in existing pipe for earth continuity including all labour charges etc., complete. as directed by the departamental authorities using Finolex/ RR kabel/ Havells KEI/ Polycab/ Gloster/ Goldmedal /GM make wire.
Supply, installation and testing of 25 mm dia UPVC Drain Piping with 6mm Nitrile Rubber class "O" Insulation covered with interwoven glass cloth protection. Necessary pipe fittings(Including enlarger, bends, T Joints etc) has to be considered to connect the UPVC drain pipe to cast iron floor trap. Including cost and Conveyance of all material and labour ect complete as directed by the departmental authorities
Providing Core Cutting in Wall for Split AC copper pipes & drine pipes as directed by the department of authority
Supply & fabrication of 1set of MS bracket suitable for fixing out door unit of split AC unit etc., complete as directions of departmental authorities.
Supply and fixing of 25mm dia. 1.60 to 1.80mm thick surface P.V.C. pipe (ISI MARK) with all accessories fixing on chromium plated metallic base saddles including Hot Dip galvanized 20/18 SWG 12 Module box for switches for Light, Fan and separate plug point including all labour charges etc., complete for run of mains as directed by the departamental authorities using Sudhakar make pipe.
Supply and Fixing of AC Metal Box apporoved make including cost and conveyance of all materials and labour charges etc., complete as directed by the departmental authorities.
Supply of (8 +24) 8 Way TPN DB Horizontal with IP 43, protection suitable for installation of 24 Nos of SP outgoing MCBs and for 1 No 4 pole, MCB/Isolator incomer along with provision for 1 No of 4 Pole RCCB/ELCB etc., complete as per IS 8623; IS 13032; IEC 61439-3. Makes: Legrand (Ekinox 3) / Schneider-A9/Hager - Novello+/ Seimens/ Havells STADx/ Lauritz Knudsen (formerly L&T) -Newrange/Indo Asian-Opti Pro/ HPL (Techno)/ Anchor (Uno Plus)/ABB-ITUS as directed by the departamental authorities.
Labour charges for fixing of (8 +24) 8 Way TPN DB with Protection suitable for IP 43, 30 Nos S.P out goings and for 5 No Incommeretc complete including cost of necessary materials i.e., screws, connection wire leds etc., and labour charges etc., complete as directed by the departmental authorities.
Supply and fixing of 100 X 50 Casing capping for AC Copper tubes suction and liquid between indoor and outdoor unit for Split/Cassette Air- Conditioner including foaming etc., complete. as directed by the departamental authorities.
Supply of 40-63A, FP MCB10KA C/D Curve ISI Mark of Makes: Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4/ Havells STADx /L&T-AU/Indo Asian-Opti pro/ HPL (Techno) as directed by the departamental authorities.