Erection of lighting conductor pole with earth pit at different place of mines due to safety reasons under Kathara Colliery
Diversion of 4 spans of existing overhead line conductor, 550V/3 phase in OCP Patch - B of East Bassuria Colliery
Erection and Dismantling of Poles, drawing of conductor and earth wire of 220V and 3.3KV overhead line Under Birsa Project.
Extension of 440 V Overhead line and changing of conductor for Power separation of Colony No. 02 of Kathara Colliery
Repairing of 30 KVA generator and laying of copper conductor from generator room to security guard room for generator connection
SUPPLY AND INSTALLATION OF 1 NO.OF JD-100 NEGATIVE SEQUENCE AND BROKEN CONDUCTOR RELAY AT SALANPUR COLLIERY UNDER KATRAS AREA
Erection Dismantling of 440V mine LT OH Line conductor, Poles and accessories near pit office at PEOCP under Hzb Area.
Replacement of damaged pole and conductor of 220V line in lodharbeda and CISF C company under Bokaro Colliery, BnK Area
Erection of pole , and conductor work of 415 volt O/H line at Chiriyatand rehabilitation village under CHP-CPP/PPR.
Dismantling and erection of conductor of 11kv GT-1 O/H line beside RK camp under Ena colliery, Kusunda Area
FLEXIBLE EARTHING SHUNT OF BRADED TINNED COPPER CONDUCTOR AS PER DY.CEE(W) PL'S DRG NO.AC-1803. FOR LHB AC COACHES
Double Compression type Weatherproof, Heavy duty Brass Cable Gland suitable for armoured cable of size 3 or 5 Core x 2.5 sq. mm, Size CBW01 or Equivalent, Double Compression type Weatherproof, Heavy duty Brass Cable Gland suitable for armoured cable ... for armoured cable of ... for armoured cable of ... for armoured cable of ... for armoured cable of ... for armoured cable of ... for armoured cable of ... for armoured cable of ... for armoured cable of ... for armoured cable of ... for armoured cable of ...
Providing and commissioning of PVC sheathed multi core copper cable 16 sq. mm x 4 core, 10 sq. mm x 4 core, and SS cable clamp for trolley no. 137 and belt conveyor no. 138 for RCB top of Raw Coal receiving bunker for Raw Coal Feeding 08 nos. bunker
Magnet cable 2 core x 35 sq. mm, 1100 V, grade flexible copper cable
Day to day 440 volts O/H line maintenance, re-erection , assembling / dismantling of O/H lines conductors , poles and associated parts like insulators , brackets etc to maintain safe and smooth power supply to Jarangdih colony , water supply , ho
Repair and maintenance of 440 volt over head line for power supply lighting line erection of poles, conductors, stay sets, insulators, cradle guard etc. at Officers Colony from P.O Bungalow (KTC) to Ch. Manager (EnM) Quarter under Kathara Colliery
Renovation and extension of 3.3 KV O.H. Line near washery colony and replacement of damaged poles and restrengthening of conductors of 440 V domestic OH lines at washery Colony and GDC colony of Gidi C Colliery under Argada Area.
REPAIR MAINT INCL REPLACEMENT OF STREET LIGHTS, PERIMETER SECURITY LIGHTS LT SWITCH GEARS OH LT CONDUCTORS LT PANELS UG CABLE ELECTRIC GEYSER CEILING FAN EXHAUST FAN WALL MOUNTED FANS SUB MAIN WIRING POINT WIRING SWITCH SOCKET LIGHT FITTING AT
Replacement of damaged service PVC conduit, junction box, bas bar, main switch in A type Block and block no 13,14,15 at central colony GM unit Dhori Area.
Replacement of damage service wire, PVC pipe Bus-bar, Din-bar, main switch and co-related work in C type quarter, P type quarters, TH type quarters with providing earthpit for safety purpose at Regional Hospital Colony under Dhori Area.
Dismantling of 220V O/H line with of 7 Nos. of poles and 7 span conductor and 1 No. lighting tower and erection of 9 Nos. of poles and 8 span conductor and one No. lighting tower at Coal Depot and mining area of ADI Colliery.
Dismantling of A Section of 3 wire 11 KV Overhead Line of Bhulan-I Feeder from Jeenagora Kali Than to Golden Sub-Station SouthTisra comprising of 36 Nos Pole of 12 Mtr overhead conductor and Erection of 10 Nos of Pole ( 12 Mtr) Conductor for extendin
Erection of 38 Nos. Of above 11 mtr pole and 3540 (1180x3) mtr. DOG Conductor and dismantling of 26 Nos. of above 11 mtr. pole and 2850 (950 x 3) mtr. Dog Conductor for diversion of existing 11 KV OH Line of Sayal-D, from Sayal OCP
Dismantling of 19 Nos. Tubular Pipe Pole 900 X 3 wire 3.3 KV Overhead dog conductor of Prabhu Feeder Operating Pump engaged in fire fighting and Erection of 10 Nos Tubular Pipe Pole and 500 X3 wire 3.3 KV overhead dog Conductor for extension of Prab
Dismantling of 5 No. Pole and 200 Mtrs 2 wire 220 Volts Overhead Conductor from old Magazine House near Flat Type Quarter of Golden Pahari and Erection of 5 Pole as well as 200 Mtrs 2 wire 220 Volts Overhead Conductor near old Magazine House Close t
12 Modular Iron Box, 12 Modular Plate, 18 Modular Iron Box, 18 Modular Plate, 6 Modular Iron Box, 6 Modular Plate, 4 Modular Iron Box, 4 Modular Plate, 4mm Copper Wire, Two and half mm copper wire, One and half mm copper wire, 1mm Copper Wire, 32 Amp MCB Box, 10 Amp Modular Box, 10 Amp Modular Socket, 25 Amp Modular Switch, 25 Amp Modular Socket, 2 Amp Fan Regulator, Indicator, 4x4 Iron Box, 1 inch Pipe, 1 inch Bend, Saddle Clip, 2 inch Nails, Round Fiber, 36 Watt Tube Light, Black Tape, Labour Charge
PVC Copper Cable Single Core and Multi Core Circular Sheathed Cable with Rigid Conductor (V2) as per IS 694 (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? No Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days Bid Number : GEM/2025/B/6360781 Dated : 19-06-2025 Bid Document 1/6 ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) Yes Inspection to be carried out by Buyers own empanelled agency Yes Type Of Inspection Pre Dispatch Name of the Empanelled Inspection Agency/Authority RITES Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Repairing and replacement of damage tap off box set, service cable and pvc conduit etc. in 6 nos. D type quarters located at GM colony and CHD colony under GM Unit, Dhori Area.
Replacement of damaged service cable, main switch, Bus bar box, junction box, main switch in 5 blocks B-type block no. 01 to 05 at Central colony under CCD, G.M. unit, Dhori Area.
Replacement of damaged service cable, junction box, Bus bar box of C-type at Shimla colony C-36 to C-41 and C-50 to C-52 under CCD, G.M. unit, Dhori Area.
185 Sqmm, Straight through jointing kit for 11 KV grade, 3 core AL Cable, 185 Sqmm, outdoor type terminal end Joint Kits for 11 KV grade, 3 Core, Al cable, INDOOR TYPE END TERMINATION JOINTING KIT FOR 11 KV GRADE XLPE ALUMINIUM CONDUCTOR CABLE OF ... grade XLPE Cable , ... GRADE XLPE CABLE , ... GRADE XLPE CABLE , ... GRADE XLPE CABLE , ... grade XLPE Cable , ... GRADE XLPE CABLE
Weatherproof Brass made double compression cable gland suitable for 4C, 10 sq mm PVC armoured cable. Overall diameter of cable -18 mm with shroud and earthing ring., Weatherproof Brass made double compression cable gland suitable for 4C, 16 sq mm PVC ... PVC armoured cable . ... PVC armoured cable . ... PVC armoured cable . ... PVC armoured cable . ... PVC armoured cable . ... PVC armoured cable . ... PVC armoured cable . ... PVC armoured cable . ... PVC armoured cable . ...
LED Batten (Q2), LED Garden Light (V2) (Q2), XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2), LED Luminaire for Floodlight (V2) Conforming to IS 10322 (Part 5/Section 5) (Q3), Molded Case Circuit Breakers ... PVC Copper Cable Single ... Flexible Conductor (V2) ... (Q3), PVC Insulated Copper Cable Single ... Flexible Conductor (V2) ...
ISI marked 33 kV XLPE UG Power Cable 400sqmm
ISI marked 11 kV XLPE UG Power Cable 300sqmm
Providing and Fixing of PVC insulated mat around the control panel at machine shop and workshop sub-station of Rajmahal OCP
PVC Insulated (Heavy Duty) Electric Cables (V2) as per IS 1554 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years Of Experience Yes | Complete Document required from seller OEM Authorization Certificate, ... category PVC Insulated (Heavy ...
Dismantling of 48 nos Rail Poles 10 nos PSC Poles 2 nos Gatar, 720 mtrs Wolf conductor and 915 Meters Dog Conductor Channel bracket 2747.34 kg and Angle 1317.79 kg for using in Diversion work of 11 kv Overhead line of feeder No 1 and 2 feeding power
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2), Xlpe Cables, Category C2 - FR - LSH, for Working Voltages From 3.3 KV up to and Including 33 KV as per IS 7098 (Part 2) (Q3), XLPE Cables for Working Voltages From 3.3 KV up to and Including 33 KV as per IS 7098 (Part 2) (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Additional Doc 1 (Requested in ATC), Additional Doc 2 (Requested in ATC), Additional Doc 3 (Requested in ATC), Additional Doc 4 (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? No Bid Number : GEM/2025/B/6927348 Dated : 02-12-2025 Bid Document 1/13 Minimum number of bids required to disable automatic bid extension 3, -- Number of days for which Bid would be auto -- extended 10 Number of Auto Extension count 1 Bid to RA enabled Yes RA Qualification Rule H1-Highest Priced Bid Elimination Type of Bid Two Packet Bid Primary product category Xlpe Cables, Category C2 - FR - LSH, for Working Voltages From 3.3 KV up to and Including 33 KV as per IS 7098 (Part 2) Time allowed for Technical Clarifications during technical evaluation 4 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Item wise evaluation Arbitration Clause Yes ( Arbitration clause document ) as per DoE OM No.F.1/2/2024-PPD dated 03.06.2024 Arbitration should not be routinely included in contracts Mediation Clause No Bid Details EMD Detail Advisory Bank Bank of India Schedule 1 EMD Amount (In INR) 196116 Schedule 2 EMD Amount (In INR) 115122 Schedule 3 EMD Amount (In INR) 35048 Schedule 4 EMD Amount (In INR) 1641 Schedule 5 EMD Amount (In INR) 769 Schedule 6 EMD Amount (In INR) 236879 ePBG Detail 2/13 Advisory Bank Bank Of Baroda (%) ePBG Percentage(%) 5.00 ( ) Duration of ePBG required (Months). 24 (a). EMD EXEMPTION: The bidder seeking EMD exemption, must submit the valid supporting document for the relevant category as per GeM GTC with the bid. Under MSE category, only manufacturers for goods and Service Providers for Services are eligible for exemption from EMD. Traders are excluded from the purview of this Policy. (b). The EMD Amount will be applicable for each schedule/group selected during Bid creation. (c)., EMD & Performance securityshould be in favour of Beneficiary, wherever it is applicable. Beneficiary : CE (GEN) Gsecl Corpotate Office, Energy and Petro Chemicals Department Gujarat, Gujarat State Electricity Corporation Limited (GSECL) Vadodara, (Company)
Erection and dismantling of 50 Nos of poles along with conductors and other associated accessories of 3.3KV OH line 220V lighting line and installation of 11KV Grade GOAB switch as and when required basis at Tapin North OCP under Hazaribagh Area
Dismantling of poles and conductors at new railway siding and repair and maintenance of 440 Volt O/H L.T line for power supply from LVS Section to P.O Office (KTW) and RLB Section to Weigh Bridge No. 2 under Kathara Washery
For repairing and breakdown maintenance of existing O/H L.T. Line (550V,440V,220V) and replacement of damaged poles, conductors, and stay sets etc. (wherever required,) due to heavy monsoon, storm and cyclone under kankanee colliery. (B). For the Ins
Miscellaneous type of electrical works i e cable shifting fitting of light retensioning of loosened overhead line conductors repairing of AB switch etc of overhead line of jarlahi section 1K pit KKC link siding and feeder breaker section of Phularita
Erection and dismantling of 160 nos. poles along with conductors and other associated accessories of 3.3 KV O/H line, 220 Volt lighting line and installation of 11 KV grade GOAB switch, installation of Lighting Transformer as and when required basis
Repair and maintenance of 440 volt over head line for power supply lighting line erection of poles conductors stay sets, insulators cradle guard etc. from Officers club to Bodia Basti, Officers Club to Durga Mandap and Staff Club under Kathara Colli
Repairing of jumpers,damaged cradleguard, B/D ABswitch and tensioning of loosened conductors, replacing of damaged stay rod, horn gap fuse and insulators of 6.6KV and 3.3KV O/H line in different places of mine premises at Muraidih, AMP Colliery
Providing and Fixing of a Phase Separator in 100 span of overhead line to prevent unwanted short-circuiting caused by the clapping of conductors with the replacement of damaged insulators and cradle guard wires, including the fixing of an electrical
REPAIRING OF AP-II FEEDER 6.6 KV OVER HEAD LINE BY CHANGING OF PCC POLES INTO RAILS POLES.OLD CONDUCTORS AND INSULATORS INTO NEW ONE AND MAKING POLE COLLER FROM POLE NO.12 TO POLE NO.20 AT OPPOSITE SIDE OF BANSJORA
Earth continuity, re-strengthening of conductor of 11KV OH Line from Murpa Substation to Kuju Colliery rest house under Kuju Area.
Dismantling and erection of damaged pole and conductor of 550 O/H line from bottom chanak to Bhuli Quarter under ADIC