MCB WITH AUXILIARY CONTACT BLOCK (1 NO + 1 NC), THERMAL RELEASE RANGE( RATED CURRENT : 16A) , BREAKING CAPACITY: 10KA, POLE: 3 P, RATED VOLTAGE : 415 V AC. Make /model: A9N3P16C + A9N26924 OF SCHNEIDE
Supply of 63A 5 pin panel mounted industrial plug & socket(IP 67 protection-IEC 60529) combined in metal enclosure protection class IP40 with green & blue color indicator & 63A 4pole MCB, 10KA breakin
Repairing, rewinding and over hauling of cooling exhaust fans, at 220 kV substation R.C. Green, Greater Noida and 220 kV substation, Sec-62, Noida, under ETD-II Noida
miniature circuit breakers, distribution or control board enclosures ( Distribution board for MCBs)
miniature circuit breakers, distribution or control board enclosures ( Distribution board for MCBs)
Propeller Type AC Ventilating Fans - Exhaust Fans (V2) as per IS 2312 (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, Certificate (Requested in ATC), OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 3, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6889267 Dated : 04-12-2025 Bid Document 1/8 Number of Auto Extension count 1 Past Performance 20 % Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No
Propeller Type AC Ventilating Fans - Exhaust Fans (V2) as per IS 2312 (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, Certificate (Requested in ATC), OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 4, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6739385 Dated : 07-10-2025 Bid Document 1/7 Number of Auto Extension count 1 Past Performance 20 % Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No
Propeller Type AC Ventilating Fans - Exhaust Fans (V2) as per IS 2312 (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, Certificate (Requested in ATC), OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? No -- Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6589460 Dated : 27-08-2025 Bid Document 1/7 Past Performance 20 % Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) Yes Inspection to be carried out by Buyers own empanelled agency Yes Type Of Inspection Pre Dispatch Name of the Empanelled Inspection Agency/Authority RITES Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Propeller Type AC Ventilating Fans - Exhaust Fans (V2) as per IS 2312 (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, Certificate (Requested in ATC), OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) -- Minimum number of bids required to disable automatic bid extension 2, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6476021 Dated : 21-07-2025 Bid Document 1/6 Past Performance 20 % Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Decorative Laminate Sheet (Q3), Bathroom or Toilet Mirror (V2) (Q4), Flameproof and Weather Proof Exhaust Fan as per IS 2148 (Q3), External branding signage boards (Q3)
Repair of work station, Interior painting, Rewiring, Exhaust Fan, Replace of window glass, Floor Matting, Technical Flex Poster with digital vinyal lamination, Acrylic sheet name plate
Bench 2 (Q3), Bench (Q3), Ceiling Fan (Q3), A4 Paper 70 Gsm (Q3), A4 paper 75 gsm (Q3), A4 Paper 80 Gsm (Q3)
REPAIR/MAINTANANCE AND IMPROVEMENT TO CERTAIN B/R ASSETS IN THE E/M INSTALLATIONS IN THE AOR OF AGE B/R-I AND REPAIR/MAINTANANCE OF INTERNAL ELECTRIFICATION INCLUDING MCBS,DBS BLDG SECURITY LIGHTS AND CONNECTED WORKS IN ZONE D AREA IN THE AOR OF AGE
REPAIR/MAINT OF INTERNAL WIRING /DBs/EARTHING, LIGHTENING CONDUCTORS, MCBS, LED FITTING, MAIN CONNECTED ITEMS AT KB, MP, BP, SHERON LINE, ODF AREA, 6 PARA, 5 PARA, 411 ENGR REGT, 801 TA, 23 PARA, 50(I) PARA BDE, NCC BN, OTM ACCN OF GE (E) AGRA
Almirah, Computer Table, Wall Fan, Light, Cloth, Glass, IPSA Channel, Keylock, Stand for CPU
Supply of Electrical Items for ESP of 2x500 MW BTPS Anpara
Providing Modular Clusters tables, Chairs, Civil work and purchase Electrical items
Replacement of defective 630 Amp MCB in AMF panel of 1x250 KVA DG set installed at Advance Imagine Building and connecting and repairing of APFC panel of TR 2 at Substation No 2
Annual work of cleaning for Turbine, Boiler, Ash handling area of Unit no 9, 10, 11, 12, 13 of 5X200 MW, BTPS and MCB, Compressor house and Sump pump house of ATPS, Obra
CRCA Sheet steel plug and socket enclosure 3P+E fitted with MCB distribution board of make Legrand , Schneiders ,Havells HPL & Hanger make only.The items is as Showns in photo attached (Annexure A) an
CRCA Sheet steel plug and socket enclosure 3P+E fitted with MCB distribution board of make Legrand , Schneiders ,Havells HPL & Hanger make only.The items is as Showns in photo attached (Annexure A) an
Supply of ISI Marked MCB, Rated current-40amp, Rated voltage- 240 volt, No. of poles/protected poles(pp) - 2 pole with 2 pp, Rated short circuit capacity-10 KA, Instantaneous tripping range- DP.
MCB 1Pole with 1 PP 240 volt rated current 10 A tripping range B rated short circuit capacity 6000 A IS; 60898-1-2002 CM/L No-7128970. As per attached GeM specification.
40 AMP 4 POLE MCB C SERIES 240 VOLT BREACKING CAPACITY 10 KVA IS :60898/2002 MAKE L&T OR SIMILAR , OPERATING VOLTAGE 240/415VOLT 50 HZ Firm's offer- Make/Brand:-"BENLO/CNS"
Four Pole MCB of current rating 32A, C curve, with Breaking capacity 10KA suitable for 415V. 50HZ AC supply, with integrated label holder, IP 20 protected terminals, colour coded ON/OFF indication con
63 AMP 4 POLE MCB C SERIES 240 VOLT BREACKING CAPACITY 10 KVA IS :60898/2002 MAKE L&T OR SIMILAR , OPERATING VOLTAGE 240/415VOLT 50 HZ Firm's offer- Make/Brand:-"BENLO/CNS"
Set of items (1) MCB base channel Drg NO.TRS/GMO/E1/3PH/052/ECR Qty-05 Nos. (2) Tail nipple drg no- TRS/GMO/M-1/G-9/123 /ECR Qty- 05 Nos.
MCB - Miniature Circuit - Breakers for A.C. Operation as per IS/IEC 60898 (Part 1) (Q2), Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3), Compression cable lugs (Q3), Piano Type Modular Domestic Fan Regulator as per IS 11037 (Q3), Piano Type Modular Domestic Electrical sockets - IS 1293 (Q3), Modular Piano Type Domestic Electrical Switches as per IS 3854 (Q3), Fixed Capacitors (Fixed Capacitor for Single Phase AC Electric Fan) as per IS 1709:1984 (Q3), LED Batten (Q2), Electrical Terminals as per IS 8309 (Q3), Electrical connection Lugs or thimbles (Q3)
2 Ton AC split, MCB 32 Amp, MCB Box, Wire 3mm, AC top 15 Amp
Propeller Type AC Ventilating Fans - Exhaust Fans (V2) as per IS 2312 (Q2) MSE Exemption for Years Of Experience and Turnover Yes | Complete Startup Exemption for Years Of Experience and Turnover Yes | Complete -- Minimum number of bids required to disable automatic bid extension 3, -- Number of days for which Bid would be auto -- extended 7 Bid to RA enabled Yes RA Qualification Rule H1-Highest Priced Bid Elimination Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days Bid Number : GEM/2025/B/6419585 Dated : 07-07-2025 Bid Document 1/6 ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause Yes ( Arbitration clause document ) as per DoE OM No.F.1/2/2024-PPD dated 03.06.2024 Arbitration should not be routinely included in contracts Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
S/I/C OF EXHAUST & VENTILATION SYSTEM FOR COOLANT MANUFACTUR LONI LUBE- 2 Top Discharge Air cooler, 50.2 Series Exhaust Fan, Exhaust Fan Electronic Controller Auto Restart, Duct GI L Bend, Duct GI Straight, Wall Stand with Railing, Dust Filter, Crystal Marbles, Auto Swing Grill, Rooftop Extension For Exhaust, Installation Cooler, Installation Exhaust, Installation Height Lifting, Installation Water Proofing, Duct XPLE Insulation
Shed for Main Gate 30ft x 15ft, Floor Matting, Peetal Water Pot 5 Ltr, Hand Wash Water Container, Painting of Sarv Dharam Sthal, Repair of Exhaust Fan
100 A 3P MCCB 25KA, 63A TPN MCB 10KA, 63A TPN ISOLATOR 10KA, 32A TPN MCB 10KA, 25A SPN MCB 10KA, 16A SPN MCB 10KA, 10A SPN MCB 10KA, SINGLE PHASE SUBMERSIBLE PUMP CONTROLLER, 20W LED TUBELIGHT, OVER LOAD RELAY, PHASE FAILURE RELAY, 1.5 SQ MM FLEXIBLE WIRE FRHR
REPAIR/ REPLACEMENT TO UNSERVICEABLE LIGHT POINTS/ FITTINGS AND MISC WORKS OF SUB MAIN WIRING, SERVICE CONNECTIONS MCB DB AND CONNECTED WORKS IN BUILDINGS UNDER AGE B/R-II AT BABINA CANTT UNDER GE BABINA
Routine/Breakdown maintenance of all Lighting panels /HPSV Lights/ACDB/DCDB/ELDB/LDB fixtures welding Receptacles and Lighting/emergency Transformer installed in 400/220 KV switchyard gantry/ LM Area and 400 KV MCB Building
REPAIR / MAINT OF DBs INCLUDING MCCBs/MCB/ ISOLATOR LIGHT FITTING, WIRING, WINDOW, SPLIT TYPE ACs WATER COOLERS, DESERT COOLERS, REFRIGERATORS, AIR BLOWERS, DEEP FREEZERS, STABILIZER SUMMER APPLIANCES AT AF STN UNDER GE AF GORAKHPUR.
REPAIR TO FLOOR AND WALL TILLING, PLASTER, PLINTH PROTECTION, FALSE CEILING, JOINERY AND SANITARY FITTINGS AND REPAIR, MAINT OF INTERNAL ELECTRIFICATION INLCUDING MCB, DBS BLDG STREET LIGHTS AND CONNECTED WORKS UNDER GE (EAST) MATHURA
20 A 1pole with 1PP 240 VOLT MCB, Rated Current (Ampere) :20 A, Instantaneous Tripping Range : C, Rated Voltage (Volt) :240 VOLT, No of poles/Protected poles(PP) : 1pole with 1PP,Steel sheet enclosure
20 A 1pole with 1PP 240 VOLT MCB, Rated Current (Ampere) : 20 A, Instantaneous Tripping Range : C, Rated Voltage (Volt) : 240 VOLT, No of poles/Protected poles(PP) : 1pole with 1PP, Steel sheet enclos
MCB 6 A 110+/- 30% VDC, Pole - 2, Breaking Capacity 6/10KA, Make:Legrand/ABB/Siemens/L&T/Schneider/Eaton /C&S only. As per RDSO spec: RDSO/PE/SPEC/AC/0184-2015 (Rev.0)
MINIATURE CIRCUIT BREAKER( MCB), current rating 10 AMP, yoltage rating:230V AC, curve -C ,pole:2P ,breaking capacity :10KA as per bill of material of RDSO specification no.RDSO/PE/SPEC AC/0184-2015(re
MCB K-Series 2 pole, current rating 32 amps. for inductive load with surge current-motor circuit application confirming to IS/IES 60947-2: Make C&S electric product code CSMBS2K32 or equivalent. Accep
Single Pole MCB , 1PP with sheet steel enclosure of capacity 16 Amp., 240 Volt, 50 HZ breaking capacity > 10 KA ( other IS & specification is as per enclosed Gem product id 5116877-89889289341), Ma
MCB DP 25 Amp. RatingMake: Hager or C&S or Legrand Rated Current Ampere: 25 AmpRated Voltage: 240 VoltInstantaneous Tripping Range: CNo. of Poles / Protected Poles (PP): 2 Pole with 2 PPSteel Sheet En
MCB current rating 2.5 / 3 Amps, 200 Volts DC, single Pole, C curve, breaking capacity 6 /10 kA to LEGRAND catalogue No. 408802 (or) ABB catalogue No. SB201-C3DC (or) SIEMENS catalogue No. 5SL51037
Supply installation commissioning of MS small tool DB size-300x600x100 mm. Thickness-1.8 mm (18SWG) MS CRCA sheet, together with 20 Amp Industrial metal clad socket=06 Nos, 20 Amp single pole MCB =06
MCB 2 Pole Current rating: 10A, Breaking capacity: 10KA, Voltage rating: 200V DC suitable for Switch Board Cabinet of LHB AC Coaches Confirming to RDSO specification no. RDSO/PE/SPEC/AC/0184-2015 [REV
MINIATURE CIRCUIT BREAKER (MCB) OF 16 AMPERE, `D' CURVE, 03 POLE, RATED VOLTAGE 415 VAC, BREAKING CAPACITY OF 10 KA, WITH DIN RAIL MOUNTED TYPE, CONFIRMING TO RDSO SPECIFCIATION NO. RDSO/PE/SPEC/01
MCB 16A 2 pole with 1PP 240 Volt, Rated Current 16 Ampere, Instantaneous Tripping range C, Rated Voltage ? 240 Volt, 2 pole with 2 Protected poles, Rated Short circuit capacity 10000A, confirming to I
REPAIR TO FLOOR AND WALL TILLING, PLASTER, PLINTH PROTECTION, FALSE CEILING, JOINERY AND SANITARY FITTINGS AND REPAIR, MAINT OF INTERNAL ELECTRIFICATION INLCUDING MCB, DBS BLDG STREET LIGHTS AND CONNECTED WORKS UNDER GE (EAST) MATHURA