Loading…
Loading…
1,448 results • Best match
Hooter, Microwave Blige Level Sensor, Dual level sensor, MCB6A, Main control Panel using milgrade 19 inch panel PC, Sensor JB, UPS with batteries, Vibrating fork type flood sensors, Analog input module, DAQ Control module, Digital input module
Supply ,Erection, Testing and Commissioning of (i) 220/33 KV Pooling Stations with indoor switchgear at proposed 160MW Wind Solar Hybrid Project to be setup near Ramagiri, Ananthapuram District by M/s SECI and connected 220KV DC Line from 400 KV SS Hindupur to proposed 33/220 KV Pooling Station (Reach-1 of 21.5 KM length) including operation and maintenance for a period of 5 years on turnkey basis .
Supply ,Erection, Testing and Commissioning of (i) 220/33 KV Pooling Stations with indoor switchgear at proposed 160MW Wind Solar Hybrid Project to be setup near Ramagiri, Ananthapuram District by M/s SECI and connected 220KV DC Line from 400 KV SS Hindupur to proposed 33/220 KV Pooling Station (Reach-1 of 21.5 KM length) including operation and maintenance for a period of 5 years on turnkey basis .
Construction of Permanent campus for IIT Tirupati at Merlapaka Village yerpedu Mandal, Chittoor District A.P Phase-1(Stage-1) Subwork/Packages: Providing of water Fountains along with Outdoor feeder piller pump control panel with accessories in Pond-2
Bifurcation of existing 11KV Randson feeder emanating from 33/11KV Morampudi SS duly proposing BRK feeder in 33/11KV Satellite City SS by erection of 3.8 Km. 11KV interlinking line & 11KV Bay extension with VCB in order to reduce the over load on existing 11KV Randson feeder in D7 Section, Rajamahendravaram of Rajamahendravaram Division in Rajamahendravaram Circle
Extension of HT supply for a CMD of 3000KVA with a CL of 2700KW in favour of the Depot Manager, APSRTC, simhapuri, Simhapuri Layout, Vepagunta,Pendurthy in operation,section Gopalapatnam rural of ZonE III Division, Visakhapatnam in Visakhapatnam ... new VCB
Bifurcation of existing 11KV Randson feeder emanating from 33/11KV Morampudi SS duly proposing BRK feeder in 33/11KV Satellite City SS by erection of 3.8 Km. 11KV interlinking line & 11KV Bay extension with VCB in order to reduce the over load on existing 11KV Randson feeder in D7 Section, Rajamahendravaram of Rajamahendravaram Division in Rajamahendravaram Circle
AS PER BOQ AND TENDER DOCUMENT
ES3439B-AE-MRLS-KRTA-EDC-001 DIGITAL MIMC DISPLAY PLAY, ES3439B-AE-MRLS-KRTA-EDC-002 TRANSRECTIFIER INPUT 415V, 1 PHASE, 50 HZ OUTPUT 27 VDC, 1KW, ES3439B-AE-MRLS-KRTA-EDC-003 TRANSRECTIFIER INPUT 415V, 1 PHASE, 50 HZ OUTPUT 27 VDC, 1KW, ES3439B-AE- ... A MCCB , ... A MCCB , ... A MCCB , ... A MCCB , ... A MCCB , ... A MCCB , ... A MCCB , ... A MCCB , ... A MCCB , ... A MCCB , ... A MCCB , ... ES3439B-AE-MRLS-KRTA-EDC-031 MCCB 400 ... ES3439B-AE-MRLS-KRTA-EDC-032 MCCB 250 ... MRLS-KRTA-EDC-033 MCCB 100 ...
Addition alteration to road
MCB - Miniature Circuit-Breakers for a.c. operation - IS/IEC 60898 Part 1 (Q2), Molded Case Circuit Breakers (Mccb)- IS/IEC:60947 (Q3)
RCCB - Residual Current Operated Circuit - Breakers as per IS 12640 (Q3), Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3)
Rectangular Single Element Induction Heater with 1 year product warranty and 3 year warranty for the heating coil equivalent to Preethi Indicook IC124. Makes: PREETHI, PRESTIGE, PHILIPS, GLEN, HAVELLS only. Specifications: 1.Top plate: Toughened ... Digital control panel with ...
AS PER TENDER DOCUMENTS AND BOQ
AS PER TENDER DOCUMENT AND BOQ
AS PER BOQ AND TENDER DOCUMENT
AS PER BOQ AND TENDER DOCUMENT
Extension of HT supply for a CMD of 3000KVA with a CL of 2700KW in favour of the Depot Manager, APSRTC, simhapuri, Simhapuri Layout, Vepagunta,Pendurthy in operation,section Gopalapatnam rural of ZonE III Division, Visakhapatnam in Visakhapatnam ... new VCB 3rd
SDSTPS - 3X800MW - Removal of spill over ash on road between 1st and 2nd stage from work shop to ECCS switch gear room via stores and Wetting of road from coal gate to required areas with water tanker for the period from the month of April- 26 to March 27.
Extension of HT supply for a CMD of 3000kVA with a CL of 2700KW in favour of the Depot Manager, APSRTC, Gajuwaka Depot, GT Road, Mulagada, Gajuwaka in Operation Section Sriharipuram of Zone -II Division, Visakhapatnam in Visakhapatnam District under ... new VCB 3rd
Up keeping and accumulated coal dust cleaning external and internal parts of electrical equipment and accessories such as HT and LT switchgear and motors, lighting fixtures, cable trays along the conveyors , lighting in under/over elevation of Marshaling yard and stacker/reclaimers , BOBR including jungle cutting at yard lighting towers , crushed yard towers and BHEL shed area in EM/CHP/Dr.NTTPS , during the period from 01-04-2019 to 31-03-2020 for the year 2019-20
50A AC3, 3phase Power contactor of type LC1E50, Coil Voltage 110 V AC 50Hz, Auxillary contacts 2 NO plus 2NC, 80A AC3, 3phase Power contactor of type LC1E80, Coil Volatage 110 V AC 50Hz, Auxillary contacts 2 NO plus 2NC, 160A AC3, 3phase Power ... LAEN22, MCCB 63A, ... LV510475, MCCB 100A, ... LV510477, MCCB 125A, ... LV516462, MCCB 250A, ... LV525453, MCCB 400A, ... LV540316, MCCB 630A, ... 100by160by250A MCCB Ref ... 400by630A MCCB Ref ...
DR.MVR RTPP-STAGE-IV-EM&MRT,I&C-PROCUREMENT OF ACB MODEL CN-CS 800S1, 4 POLE L&T MAKE CIRCUIT BREAKER & ITS SPARES PERTAINING TO ESP ACP PANELS- OFFER-REQ-REG
AS PER BOQ AND TENDER DOCUMENT
AS PER TENDER DOCUMENTS
MCB - Miniature Circuit - Breakers for A.C. Operation as per IS/IEC 60898 (Part 1) (Q2), Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3)
Two (2) Year Maintenance Contract for Switchgear, Busducts, Hoists, EOTCranes and Air Conditioners (Window AC, Split AC, Package AC, WaterCooler, Hydrogen Gas Drier) in Main Plant and Offsite Areas at NTPCSimhadri.
Design, Engineering, Manufacturing, testing at manufacturer's works before dispatch, Supply, transportation, storage at site, insurance, erection, testing and commissioning of 12Nos., 80MW capacity Vertical full Kaplan Turbine Generator units along ... Insulated Switchgear & ...
Up keeping and accumulated coal dust cleaning external and internal parts of electrical equipment and accessories such as HT and LT switchgear and motors, lighting fixtures, cable trays along the conveyors , lighting in under/over elevation of Railway Marshaling yard and stacker/reclaimers , BOBR including jungle cutting at yard lighting towers , crushed yard towers and BHEL shed area in DE/EM/CHP/Stage-I, II , III/Dr.NTTPS , during the period from 01-04-2018 to 31-03-2019 for the year 2018-19
Up keeping and accumulated coal dust cleaning external and internal parts of electrical equipment and accessories such as HT and LT switchgear and motors, lighting fixtures, cable trays along the conveyors , lighting in under/over elevation of Railway Marshaling yard and stacker/reclaimers , BOBR including jungle cutting at yard lighting towers , crushed yard towers and BHEL shed area in DE/EM/CHP/Stage-I, II , III/Dr.NTTPS , during the period from 01-04-2018 to 31-03-2019 for the year 2018-19
Repairs to Existing pump sets at No-1 Pump House No-3 Raw water 25 HP& Clear Water40HP, No-2 Raw Water pump 2, No 2 Pump House N0-3 30HP pump, No-2 Pump House No-1 30 HP pump, 6Sq mm copper cable and MN 40 Starter Beds, 160amps MCCB, 100AMPS MCCB at Head Water Works in Tadepalligudem Municipality
AS PER TENDER DOCUMENTS AND BOQ
AS PER TENDER DOCUMENTS AND BOQ
Dismantling and Shifting of New HP Air Compressor from Kritika workshop building to P-336, Dismantling of Old Compressor, Disconnection of Associated Pipe Lines, Cables and Electrical Panels and Segregation of Items Material Wise, Preparation of ... and Electrical Panels , ...
Contactor for Time relay VCB (Pos no 136.3) and power supply to cab and accessories ( 126.7) as per Para no 8 of scope of supply of CLW Spec no CLW/ES/3/0064 Alt-C or latest. Note: CLW approved sources shall only participate in the tender or supplier offers shall be considered with valid tender specific authorisation certificate from CLW source shall be submitted along with their offer.
Rectifications of lighting circuits at higher elevations, maintenance of welding TB circuits of boiler 5&6 all floors, ESPs, TG floor, '0' meters, '5' meters elevation, Tranformer yard and compressor house , Annual Up keeping of Switch gear rooms and cable galleries,soot blowers of Unit 5 & 6, as and when required during the year of 2026-27.
Repairs of existing pump sets in pump houses 1, works 250KVA Generator, Bearings and 800 amps ACB Panel Board and 4 pole Change over switch at head water works for ensuring Summer 2026 in Tadepalligudem municipality.
REPAIR/CALIBRATION OF FIXED DD FIRE PUMP SEA WATER DISCHARGE FLOW METER VIEW NON OPS, REPAIR CALIBRATION OF 37 TPH PORTABLE DD FIRE PUMP DISCHARGE FLOW METERS VIEW DEFECTIVE, REPAIR/OVERHAULING OF CHILLED WATER BALANCING FLOWMETER VIEW LEAKAGE, ... FLOWMETER CONTROL PANEL IN ...
EH9180B-SPSTAXH3 ZAREBA SENSEPOINT H2S DETECTOR, EH9180B-GN-303-0001 CONTROL PANEL, EH9180B- 2306B1000 UNIPOINT CONTROLLER MA VERSION, EH9180B-HFIP66-230VAC FLASHER CUM HOOTER UNIT IP66 230V AC, EH9180B-GN-042-0001 GONG BELL 4 230VAC, EH9180B-GN-304-0001 SIGNAL ISOLATOR WITH TPS, EH9180B-42-000-0000 H2S CONCENTRATION DISPLAY SYSTEM
Wilfit Spares, distribution or control board enclosures ( Distribution board for MCBs), PVC Copper cable Single and multi core Circular Sheathed Cord with flexible Conductor as per IS:694, Wire mesh fabric or cloth, Ceiling Fan - BLDC Bidder Turnover (Last 3 Years) 5 Lakh (s) Experience Criteria 2 Year (s)
1) Supply, Delivery fixing of 1.0HP Mono block Motor and Repair of Panel board materials (water plant pump set) at Municipal corporation old building & 2) Repairs for 7.5 HP Submersible Pumpset (PS No: 246/16) at Konne palli. and 3) Replacement of ... & control Panel Board ...
Street Light, MCCB, Aluminium Lugs, Power Conductor, Timer Switch, 3 core copper cable, Street Light LED, LED Flood Light, LT UG XLPE Cable, Cable PVC Aluminium BOQ Title BOQ 1 ELELCTRICAL ITEMS
06-05-2026 09:00:00 ELECTRICAL OFFICE, INS SHIVALIK DOOR LIMIT SWITCH, MCCB 800A BREAKER, 35 DEGREE VISUALLY SECURED FLOOD LIGHT 24V, 150W C/W LAMP, BREAKER 10A MINATURE T. P
Procurement of 8Nos various outdoor VCB spares suitable for various makes of VCBs 1)Spring Charging Motor with Bridge Rectifier 2) Spring Charge motor with gearbox ERL/ Stelmec/CGL Delco Motor 3) Big Cam with Main shaft with bearings with gunmetal material 4) Closing Latch Assembly (System control, Megawin, BHEL) 5) Remote/Local Switch 6) Master trip Relay 2 NO &2 NC 7) Alstom Ratchet wheel Assembly and SS pin with gun metal 8) Anti-Pumping & Timer Circuit
Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6755399 Dated : 05-10-2025 Bid Document 1/5 Number of Auto Extension count 1 Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No
OUTPUT TERMINAL FOR ESAB 600I SMAW MACHI, CONTROL PANEL ARC 601I FOR ESAB 600I SMA, AXIAL FAN MIG 300I ARC601I FOR ESAB 600I, HALL SENSOR ARC 601I FOR ESAB 600I SMAW, CONTROL TRANSFORMER ARC 601I FOR ESAB 60, TIMING DRIVE BOARD ARC 601I FOR ESAB 600, IGBT MODULE ARC 601I FOR ESAB 600I SMAW, INVERTER BOARD ARC 601I NEW FOR ESAB 60
Shifting of 33KV CTs from existing VCB structure to proposed cantilever structure on line side TC Towers for 6 Nos 33KV Feeders at 132KV SS Madanapalle in Annamaiah District Under RMI 2024 2025 Scheme
Isolator switch (Q3), Power Contactors as per IS 13947 - 4 - 1 (Q3), HRC Fuse as per IS 13703 (Q3), Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3) MSE Exemption for Years of Experience and Turnover
S&F Air Conditioner 1.5 TR 3 star, S&F Voltage stabiliser 230V with capacity of 4KVA, M&L for wiring including PVC conduit pipe, S&F Plug & Socket and MCB SP 20A, Cable, MCCB BOQ Title BOQ BOQ
Supply and fixing of 11 Lakh SMC Meter Boxes with clamps, 11 Lakh 3P 415V 40 A MCCB, 11 Lakh Shunt Capacitors, 10 sqmm twin core PVC cable and 10 sqmm single core PVC cable, 11 lakh 20 mm dia 1.5mts Long Electroplated Spike Earthing. And GI wire No.8 and fixing of Smart Meters (Supplied by another agency) in SMC Meter Box and other material as per the specification to 11 Lakh agriculture service premises to capture Agricultural services consumption data in Nellore, Chittoor, Kadapa, Ananthapur and Kurnool Districts under YSR Uchita Vyavasaaya Vidyut Pathakam with 100 Percent CAPEX Model