Complete Repairing/Overhauling of 400 Amp.11KV VCB Switch Make Electrotechnica Sl.No.SGI-2306 CTR-150/75/5 Main Controlling of Feeder one Controlling Switch at 7 Pit New Sub-Station Jealgora Local Id No.Jeal/SW/31 of Amal. Joyrampur Colliery under L
(A)REPAIRING AND OVERHAULING OF 400 AMPS VCB SWITCH 6.6 KV,MAKE MEDITRON SL.NO. 9367 AT KANTAPAHARI SUB-STATION (B) COMPLETE REWINDING OF 160 HP MOTOR MAKE- CROMPTON GRAVE, 550V, RPM 1470, SL. NO- RUY/044 AT RAMKANALI COLLIERY UNDER AKWMC,KATRAS AREA
Complete Repairing and Overhauling of 1 No. HT Switch 11KV 400 Amps.Andrewyule Make VCB Switch Sl. No.2917 Local ID No. JOY-3/SW/2 for Controlling of 1MVA Power Transformer 3 Pit Sub-Station Main Switch at Joyrampur Colliery under Lodna Area.
Repairing of 11KV 400amps A Yule make VCB switch Sl No 3850 for controlling of 750KVA transformer 550volts at Madhuban new pit sub station and repairing of 800amps Erskine heap make 550volt Sl No 327461 for controlling of KKC link feeder breaker and
Kit of Vacuum Switch tube for Single Bottle VCB Type BVAC suitable for M/s BTIPL make or M/s AAL make only as per Annexure attached. BTIPL Pt. no.- HSBA331624-R1 with latest Alt, AAL Pt. no.- SG300142R0001 with latest Alt.
Complete Repairing of 1 No.400 Amps 3.3 KV Mine Line Make FLP VCB DOL Starter 800 GPM Pump and Motor( locak Id. No. LC/ST/166) for Controlling of 225 KW Motor in Face Side at Kujama Colliery under Lodna Area.
Providing a retaining wall for cable trench, strengthening of earthing system of ATR and SST, erection of surge arrestor (132 kV) and VCB (SST) and approach road for repair and maintenance of 220/132 kV, 150 MVA ATRs at GSS, Adityapur-II (RCP)
(A) Repairing of primary control of FLP type 315 KVA, 3.3kV/550V TSU, Electrotechnika FLP Sl. No. 1053 installed at 40L/6MD (B) Repairing/ reconditioning of 04 No. VCB panel, 1250 A, Make Meditron 3.3kV installed at CRO Sub-stn in Churi Colliery.
Providing and fixing of E/L Relay with CBCT Breaker Charging Motor, Vacuum Interrupter and other items in different 08 Nos VCB of rating 11KV and 3.3KV at Main Sub-Station Saunda-D for Protection and safety purpose at Saunda-D Colliery.
Complete Repairing and Safety Protection of 1 No.H.T.Switch 3.3 KV 400 Amps Electrotecnica Make VCB Switch Sl. No.FCB-060 and Local Id.No. LC/SW/209 for Controlling of 250 KVA Lighting Line Transformer Main Switch at 1 Pit Sub-Station Lodna Colliery
Complete Repairing of 3.3 KV 400 Amps Mine Line Make FLP/VCB Star-Delta-Starter Controlling of 1000 GPM Pump of Paharigora Drinking Water Supply local Id. No. BCCL/ JGOCP /FLP/JN/JG/SW/3.3 KV/57 of Amal NT-ST-JG OCP
Painting of power transformer 02 nos lighting transformer HT switches 11KV 400amps OCB switch and 3point3 KV 400 amps VCB switch and 11KV 400amps switch make and 400amps OCB GEC make switch and room gate fire area substation and changing of power co
Complete Repairing/Overhauling of 400 Amp.11KV VCB Switch Make Electrotechnica Sl.No.SGI-2306 CTR-150/75/5 Main Controlling of Feeder -I Controlling Switch at 7 Pit New Sub-Station Jealgora Local Id No. Jeal/SW/31 of Amal.Joyrampur Colliery under Lo
Repairing of 3point3KV 400amps GEC make OCB switch Sl No M628 for controlling of secondary 3point switch at Damoda albion substation of Damoda Colliery and repairing of 11KV 400amps VCB Bieco lowrie make switch switch Sl No 7760 for controlling of 1M
Part repairing of TSU switch 400amps 3point3KV FLP VCB make mainline Sl No 923 at 10L 3D of Benidih underground Phularitand and Part repairing of 750KVA 11KV 550volt transformer for east india ltd make Sl No 5854 1 Benidih feeder breaker substation o
Repairing and reconditioning of 5 nos. of vacuum circuit breaker (i) 02 nos. of 11kv 400 Amps, Sl. No.9667, 9668, Make Electroteknica installed at CSS (ii) 01 no. 11kv , 630 Amps VCB, Sl. No.2286, Make Andrew Yule installed at Intake well
Dismantling of 2 core CT, supply and installation of 3 core new CT at 11 KV VCB switch of incomer -01 of transformer no 01 (33KV/11KV 10 MVA) for connection of deferential relay at south Loyabad Sub-station under Kusunda Area.
Complete Repairing of 400 Amps 3.3 KV Sait Mineline Make VCB Switch Sl.No.1216 and Local Id.No. BCCL/JG/SW/3.3KV/61 for Power Controlling of 3.3 KV side of Power Transformer at 6 pit Bararee of Amal. Joyrampur Colliery under Lodna Area.
Set of Spring-loaded Switches for Pantograph, VCB & Hotel Load consists of 03 items in 06 Nos. as per CLW Spec. No.- CLW/ES/3/0075 (Alt.-C) (Type-B Scope of Supply CLW Spec. No.-CLW/ES/3/0075, Alt.-C).
Repair kit for Pressure Regulator (Part No. 4300021000) of AAL make VCB. Set Consist of 3 items. 1) Valve cone Pt. No. 4300018900 - 01 No. 2) Diaphragm Assly Pt. no. 4300019000 - 01 No. 3) O ring 30X2 mm Pt. No. 69.211.215 - 01 No.
Kit of Vacuum Switch tube for Single Bottle VCB Type BVAC suitable for M/s BTIPL make or M/s AAL make only as per Annexure attached. BTIPL Pt. no.- HSBA331624-R1 with latest Alt, AAL Pt. no.- SG300142R0001 with latest Alt.
For providing and installation of 4 nos. of JVS make Earth Leakage relay Model-JRC-072 in Various control panel of Mudidih Colliery Substation under Sijua Area
Providing and fixing of MCCB 800A at Thakur Colony transformer under Kathara Colliery
Work of erection of poles for fixing of GO switch and MCCB for the primary and secondary control of transformer AND replacement of damaged pole in LT OH near WB area, heightening of Fd No 1 (HT OH) near Pit Office and dismantling and fixing of 1 POLE
VACUUM INTRRUPTER 12KV 25KA 800AMP for spares of 11KV & 3.3KV VCB for PCE Project pvt. ltd., PT DRY TYPE 3P EPOXY 11KV 200VA IS3156-I for spares of 11KV & 3.3 KV VCB for PCE Project pvt. ltd., PT DRY TYPE 3P 3.3KV 100VA EPOXY MOULDED for spares of ... 3.3KV VCB for ... 3.3KV VCB for ... 3.3KV VCB for ... 3.3KV VCB for ... 3.3KV VCB for ... 3.3KV VCB for ... 3.3KV VCB for ... 3.3KV VCB for ... 3.3KV VCB for ... 3.3KV VCB for ... 3.3KV VCB for ...
Surge Protecting Device (SPD) Type 1+ 2, DC-DC Voltage Converter (DC-DC buck converter), Surge Protection 48 V DC Type 3, PVC Distribution Board
671015020165, 670500000086, 671015020164, 671015020163, 671015020162, 671015020161, 671015020159, 671015020160, 671015020070, 671015020158, 670710086697, 671015020157, 671015020156, 671015020155, 671015020154, 671015020153, 671015020152, 671015020151, 671015020150, 671015020133, 671015020132, 671015020131, 671015020130, 671015020139, 671015020134, 671015020149, 671015020138, 671015020137, 671015020136, 671015020135, 671015020148, 671015020147, 671015020140, 671015020146, 671015020145, 671015020144, 671015020143, 671015020141, 671015020142
Electronic control Panel, Smoke detector, Temperature sensor, Evacuation siren, Manual Points, Nozzle Spray, Solenoid Valve, CO2 gas cylinder, Seamless pipe, Copper cable, Clean agent type Automatic Extinguishing System
(A). For the repairing and overhauling of VCB 400 A 6.6 KV Make Prabhu at Kankanee Colliery. (B). For Repairing of TSU, make Electroteknica, Sl. No.- 10/40 at TOCP Sub-Station, Tetulmari Colliery. (C ). For complete repairing/over hauling of 6.6 KV 4
Providing and fixing of 18 nos. earth leakage relay with CBCT, test reset return switch OCB shunt trip coil in different VCB and OCB at main 11 KV/3.3 KV sub-station for protection and safety purpose under Bhurkunda Project under Barka Sayal Area.
repairing and reconditioning of A. 11 KV 800Amp, Prabhu make sl no 0526 VCB Switch of feeder 1 and B 3.3 KV, 400Amp OCB Crompton greaves make sl noKUGP.OCB.CCL001 used for primary control of lighting transformer 630 KVA 3.3KV 440V installed at main s
Repairing and maintenance of 1250Amp, 33KV grade SF6 Voltas make Sl No.6164/97and 3.3 KV grade 1250 Amp Andrew yule make VCB Sl No.2730 and 3.3KV side Bus-bar and GOAB maintenance for 3 MVA Power Transformer second feeder at main substation PEOCP
Dismantling, laying and diversion of 3 range of 8 in (1000m) and 10 in (800m) diameter pipeline with all electrical accessories(6.6KV starter-VCB) for multiple Shifting (stepping up and lowering down) of Pump-Motor set for a period of 12 months(365 d
Providing and fixing of CT, Vacuum Interrupter, PT Fuse, E L Relay with CBCT, Aux. Contactor, HT Bushing with stud 3.3KV Grade and other items in different 03 Nos. VCB of rating 3.3KV at Birsa Quarry for protection an safety purpose at Birsa Project
Shifting, pulling with installation of 03 nos VCB 11KV grade, earth continuity for G.I strip(50mm x 6mm) with re-organization of bus-bar for feeding power to KSI, Bokaro, IWSP feeder ,Dismantling of 03 nos OCB and making of 03 Nos. Switch foundation
Repair, maintenance of 02 nos. switches of 3.3KV, 400 Amps. 1) 01 no. VCB Andrew Yule make Sl. No. 7195 controlling Dhori Patch feeder and 2) 01 no. OCB Brush make Sl. No. MRSS-02 controlling BSI feeder in r/o MRSS, BnK Area.
Erection and extension of 11KV OHLine by tapping from main 11KV OH Line near Chatniya basti to Pit Office at Kuju New Siding and erection and febrication of shade for installation of 250KVA transformer and VCB at Kuju New Siding of Topa OCP under Kuj
Complete repairing of VCB Switch (A) 3.3kV, 400 Amp. Make Electroteknica, Sl. No. FS-374, supplying power to face pump feeder and (B) 3.3-6.6kV/110V, CT 120-60/5plus5 Amp. Make Electroteknica, Sl. No. SP/0/400 supplying power to Shovel No. 05
repair of (A) one no. 6.6 KV, VCB switch, 400 Amps, make-Meditron, SI. No.7741 installed at 03 no. quarry and (B) one no. 3.3 KV, 400A.VCB Switch make WNP installed at 4 no. pani tanki for power supply to colonies under Kathara Colliery.
Repairing of 11KV 400amps Bieco make OCB switch type NFLP Sl No 1956 for controlling of 750KVA 11KV 440volt transformer and repairing of 11KV 800amps VCB switch Bieco make type NFLP Sl No VB8A 7764 for controlling of 11KV all main Damoda Colliery at
Dismantling of 03 Nos of 33KV MOCB and installation of 03 Nos of New 33KV,1250A VCB (Sl. No.116472P, 116473P,116476P) for washery-1 feeder, 20mva-1 and 20mva-2 transformer in place of the same at Madhuban DG Substation under Block II Area
(A)Partial Repairing of 550 Volts 200 H.P. Star-Delta-Starter VOLGA Make Installed at South Tisra pumping site Local Id.No.BCCL/ST/STRDT/550V/26 and (B) Complete Repairing of 3.3 KV 400 Amps VCB Type VOLGA Make original Sl. No. 014 Star-Delta-Starter
(A)Complete repairing of 3.3KV, 400Amps VCB switch Andrew Yule make type NFLP, Sl.No.3837 and (B)repairing of Bucholz relay WTI and OTI protective device 11KV/3.3KV transformer for controlling of F.N.-2 upper side S/S of MOCP F/B of AMP Colliery.
A. Repairing of 750 KVAR capacitor bank installed at main sub station AKKOCP (BOQ 1-5), B. Repairing maintenance of 01 no. 500 KVA, 11KV/440V distribution transformer and Repair and maintenance of 3.3KV /400 Amp VCB switch make andrew yule sl no 060
(1) COMPLETE REPAIRING/OVER-HAULING OF 6.6KV/400 AMP,VCB SWITCH WITH BUSBAR,SL.NO.455357/01 GEC MAKE AT KANTA-PAHRI S/STN (2) COMPLETE REPAIRING/OVER-HAULING OF GEC MAKE OCB SWITCH,6.6KV/400 AMP SL.NO.5717 AT KANTA PAHRI SUB-STATION UNDER AKWMC
IOH replacement kit for single bottle VC [IOH replacement kit for single bottle VCB of M/s Schneider Electric type -22CB consisting of 14 items as per Pt.no.- 5510750 Confirming to RDSO SMI no.- ELRS/SMI/0236(Rev.1) dtd.31.12.12 as per annexure attached .]
Providing and fixing of E/L relay with CBCT, IDMT relay, CT, HT bushing, 3.3KV vacuum contactor coil and other items in 02 nos. 11KV or3.3KV OCB and 02 nos. 3.3KV VCB starter at Balkudra substation and quarry at Bhurkunda Colliery under Barka Sayal.
Running Repair/maintenance of 06 nos. of VCB 11 KV/200A, 03 nos. of 11KV/400A, 01 no of 11KV/600A make Meditron Sl. No. 7712, 7713, 7714, 7715, 7716, 7718, 7719, 7720, 7721, 7722 type-Indoor installed at 33KV Main Regional Sub-station (MRSS)
H.T. Switch 3.3 KV 400 Amps Prabhu Make VCB Switch Sl.No. 98/2010 Local Id.No. BCCL/ NT-ST/SW/14 for Controlling of 250 KVA and 100 KVA Lighting Line Transformer Main Switch at Sector -II MOCP of Amal.NT-ST-KJ Colliery Under Lodna Area.
Repairing and renovating of 02 Nos of controlling switches (A) ECE make, 3.3KV, 400A OCB Switch, WNP, Punch Sl. No. BnK/IWSP/OCB/3.3KV/04 used for controlling of 300KVA transformer and (B) Meditron make, 3.3KV, 400A VCB Switch, sl. No. 0004-3905 used