For repairing, overhauling 400Amp, 6.6KV VCB Switch make Andrew YULE Make Sl.No.2843 at 3No, Sub-Station Mudidih Colliery Under Sijua Area.
complete repairing of 3.3kV 400Amps VCB Star-Delta starter Prabhu Make non FLP S.N.HT 577 for 4000GPM pump at NOCP under Sijua Area.
1.Dismantling of different defective components 2.Repairing of isolator 3.Wiring repairing with charging shaft mechanism for VCB isolator and safety device.
1. Dismantling of different defective components. 2. Repairing of isolator. 3. Wiring repairing and charging shaft mechanism for VCB,Isolator and safety device.
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Coal Mines; Providing fixing and replacement of 440Volt LT 1600 Amp ACB Air circuit beaker at Sub station of Rajmahal CHP; Service Provider
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Coal Mines; Supply and fixing of some spares for BOCB 6600V and ACB 440V for maintenance work at Workshop sub-station; Service Provider
Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3) ( PAC Only ) MSE Relaxation for Years Of Experience and Turnover Yes | Complete Startup Relaxation for Years Of Experience and Turnover Yes | Complete Document required from seller ... ( MCCB ) ...
ELECTRODE, M-E 901, CUT TRODE I, 4MM, ELECTRODE GOUGING, 2-4MM, CUTNG, ELECTRODE, STL, 3.15MM, LOW H2, ELECTRODE, WELDALLOY 307, 4MM, 350MM, ELECTRODE, 4MM, 450MM, MN STEEL, HRD FCNG, CYL, CCL 10, 100T HYD JACK, BRKR CRCT, MCCB, 100A, 415V, 3P, BRKR ... CRCT, MCCB , ...
For repairing of 6.6KV, 400Amp VCB ( two numbers) Sl. No. 2490 and 2431 of AY Make of Capacitor Banks at SBRS, under Sijua Area
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Coal Mines; Repairing of VCB 630A 6600V Crompton make of DG substation; Service Provider
TURBINE DISCHARGE MEASURING EQUIPMENT (WINTER- KENNEDY TYPE) (Q3), DIFFERENTIAL PRESSURE TRANSMITTER (Q3)
ForRepairing of AB switch of Ghurni Joria Basti and bright kusunda colony S/S along with installation of MCCB switch is respect of ADI colliery of kusunda Area
Complete overhauling of 33KV 1250A VCB make Electroteknika Sl no. 900251 for stand by (main controlling of Jarangdih feeder) of regional substation under Kathara Colliery
For Complete repairing of 11 KV ,400 Amps, VCB at Nichitpur Substation working as Main incoming of Main Substation 11KV Nichitpur Colliery under Sijua Area.
Supplying and Laying of 11 kV HT Cable with other accessories by meansof Underground in HDPE pipe by HDD technology and through wall mountedtrays from miscellaneous switchgear room to main township at PVUN Ltd
Lifting Pulling Machine 8 Ton, Digital Timer, MCCB 63Amps, Chemical Earthpit, LED 150 Watt, Grease Graphite Packing 12mm, Gland Packing Graphite Teflon Type 16mm, Gland Packing Graphite Cotton 19mm
For complet repairing / overhauling of 3.3 KV 400 Amp VCB Switch Andrew Yule make with busbar Sl.No.3867 at Nichitpur Main Sub-station under Sijua Area
For maintenance of 400 Amps.11KV grade Andrew Yule make VCB and 400 Amps 3.3 KV Crompton make OCB of Nichitpur main Substation under Sijua Area
For Heating, Testing and de- carbonisation of Various nos. of 400 Amp, 11KV OCB and one Nos. VCB Installed at Main Sub-station of Nichitpur Colliery
Complete overhauling and rewiring of 2 no. of 33KV Alstom make VCB and its controlling panel for the Moonidih Sub-Station. Sl.No. 17500/P3, 17496/P3.
Designing supplying installation and commissioning of motorised mechanism outdoor type and interlocking with 33 kv grade gang operated horizontal type air break isolator with switchgear installed at 33 KVA sub station under AKKOCP, BnK Area.
Providing and fixing of GOAB Switch 3.3KV / 800A with lightning arrestor n 800A MCCB for smooth supply of power from 630KVA, 3.3KV/440V Transformer at Jhirkey village under Kathara Colliery.
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Coal Mines; Repairing replacement and overhauling of 02 Two Nos 1000Amp ACB Air circuit breaker panel for 630KVA and 500KVA transformer running at deep mines of Rajmahal..
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Non- comprehensive AMC for a period of 2 years for L&T make Air Circuit Breaker ACB at HURL, Sindri; As per scope of work
Repairing of 11KV, 400 Amps, VCB, make Electroteknica acting as controlling switch of 200 KVA, 11KV, 440V Transformer installed at sector 2 SS of East Busseriya Colliery
For repairing/ overhauling of 400 A, 3.3 KV VCB HT Breaker, make Prabhu Sl. No. 83/2009 at 7/8 Sub-station Tetulmari Colliery under Sijua Area
On site Repairing of 02 Nos. Isolator for 3.3KV VCB starter ,Mine Line make for controlling of HT Motor Pump Set of Potanga Quarry under Urimrari OCP.
Assistance to maintenance work in respect of HTLT Switchgear Panels, HTLT Motors, 415V MCCs and Telephone Exchange other Elect Installations and Assistance to operational activities of CW Pp House, Battery charger,415V MCCs and electrical equipmnts.
Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3) ( PAC Only ) MSE Exemption for Years Of Experience and Turnover Yes | Complete Startup Exemption for Years Of Experience and Turnover Yes | Complete Document required from seller Experience Criteria, Certificate (Requested in ATC), OEM Authorization Certificate, Additional Doc 1 (Requested in ATC), Additional Doc 2 (Requested in ATC), Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 1 Bid Number : GEM/2025/B/6985463 Dated : 11-12-2025 Bid Document 1/10, -- Number of days for which Bid would be auto -- extended 7 Number of Auto Extension count 1 Bid to RA enabled No ITC available to buyer Yes Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 4 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Estimated Bid Value 154226 Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No
MCCB, 800A, 415V, 4 POLE, 3PHASE With enclosure, Kit Cable Jointing 70sqmm, Moving contact 800 A, 11KV, Finger Contact Assembly 400A, Contact blade type, 800A, 11KV, Shunt Trip Coil, 220V, 50W
FUSE CRTRG, HRC, 50A, 6.6KV, BRKR CRCT, MCCB, 20-25- 32A, 240V, 1P, 100A, 415V, 3P, 200A, 600A, 4P, 50HZ, CONTACTOR, ML 12, COIL, 110V, TEST KIT, SCNDRY INJCTN, I- P230VAC
Miniature Circuit Breakers (MCB) for AC Operation Marked To IS/IEC 60898 (Part 1) (Q2), Moulded Case Circuit Breakers (MCCB) Conforming To IS/IEC 60947 (Part 2) (Q3), DOL starter (Q3)
For complete repairing and overhauling of controlling switch (VCB), Make- Electrotechnica, 6.6KV , Sl.No. SGI9024, Asset Sl. SBC/21 at IV seam of Sendra Bansjora Colliery under Sijua Area.
Complete repairing and reconditioning of One No. 11KV 1250 Amp. Andrew yule make VCB switch Sl. no 1725 at Substation no. 2 of Kathara Colliery under Kathara Area
Repairing/Overhauling of GEC Make 800AAmp OCB 440V Sl.No.40/0097 at Main Substn NPC(ii)Comp.Rep./Overhauling of GEC Make 400Amps OCB 440V Sl.No.30/0033 at Main Substn.NPC(iii)Fabrication and Installation of 2 Nos.of interlocking setup between AB
BUS CONNECTION SET, BHEL, CB, 11KV, BUS BAR CONNECTION, 35216602010, BHEL, BUS BAR CONNECTION, 35216601865, BHEL, BUS BAR CONN SET RYB, 35216602601, BHEL, BUS BAR, 12X200CU, BHEL, VAC CB, 11KV, BUS BAR, 25216901502-V01, 12X200, AL, BHEL, BUSBAR, ... BHEL, VCB , ... BHEL, VCB , ...
FDN 160/100A, MCCB, 50KA, 3P PART NO-FDN36TD063ED, LT WIRE 8MMAUTOPAL, WIRE LT CABLE 4MM 241012, FIXED CONTACT 800A 415 V, INSULATED RUBBER MAT 11KV 4FT 3FT 2.5MM, MOVING CONTACT TIP ASSEMBLY
Repairing and overhauling of 4 nos. 11KV grade, (3 nos. Reyroll burn make , 400Amp, OCB and one no. Meditron make, 800Amp VCB) of controlling switchgears installed at HT sub-station.
Towards repairing/ overhauling of 6.6KV grade, VCB OCB 400 Amp Switch Sl. No. 696 Asset reg. no. SBC/25 at Gareria Sub station of Sendra Bansjora Colliery, under Sijua Area
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Coal Mines; Repairing and overhauling of 02 (Two) Nos VCB 630A 6600V Crompton make at DG Sub-Station; Service Provider
Design Engineering Supply of Materials Equipments Erection Testing and Commissioning of its 132 and 33 kV Transformer Bays -Hybrid Switchgear Type Bay for 132 KV and 33 KV side- at 132-33 kV Grid Sub Station Garhwa Road on turnkey basis
33(E)/33(UE) KV grade, 1C× 630 sq. mm, H4-grade Aluminium conductor, XLPE-insulated, FRLSH (Category C, 36 KV Indoor Metal-Clad Switchgear-cum-Metering Panel with FRTU (remote operation), 36 KV Terminal Isolator (HL) without Earth Switch
For repairing/overhauling of 400 A, 6.6 KV VCB Switch make-Andrew Yule and Co.Ltd.Sl.No.2843 Main Incoming 6.6 KV at Mudidih No.3 Substation of Mudidih Colliery under Sijua Area.
Repairing of HV Motor Star Delta Starter FLP Make-Mine Line Pvt.Ltd.Sl.No.HS-20121,3.3KV,VCB,400A for installation of pump in main dip of UG mine of Kharkharee Colliery under Govindpur Area.
Repairing of 02 nos. of 3.3KV VCB starter make Prot India and Sail and 02 nos. of 3.3KV field switch make Reyroll Burn installed at EnM section of AADOCM, Dhori Area.
Repairing/Overhauling of GEC Make OCB 400A.550V Sl.No.314711/49 at Ekra Substation Basdeopur(ii)Rep/Overhauling of 400Amp,440V LT Switch Make-Reyroll Sl.No.CB952 at Coke Plant Substation LBC(iii)Rep/Overhauling of 800Amp,550V/440V ACB Make-ABC Sl.N
Providing and fixing of 1 no. 800 Amp. And 1 No. 630 Amp. MCCB/DTH at different locations of Religara Colliery and Providing and fixing of rubber mat for Religara main substation under Argada Area.
For 6.6KV,O/H Line for installation of A.B Switch, installation of VCB(HT) Earth Pit and Erection of 220V,Lighting Line at C.I.S.F Check Post and Sendra Jore under Kankanee Colliery
Repairing of 2 no. 11KV VCB 400Amp and 1250 amp make Electroteknica and Andrew Yule having S.No. IS -211 and 2541 respectively of main A K Saunda Substation at Central Saunda Colliery.
(i)Asst. to maint. and opn. activities of elect. equip. associated with BTG Ctrl Room Gen Pedestal Lighting installations and equip of AHP of BokaroB TPS (6 nos Labour) (ii) Asst. to maint. work i.r.o. 6.6 KV 415V Switchgear panel (8 nos. Labour)