Loading…
Loading…
1,598 results • Best match
CKD Make Filter cum Regulator, Part No. W2000-10-W-CKD-M1 compatible to AAL make VCB along with input output bolts and pressure gauge. Make: CKD only. Note: Firm should submit authorized dealership ce
Set of items for VCB type 22CB. Set consist of 06 items as follows: (1) Air pipe with coupling (Reservoir to regulator) to schneider pt.no. NPRM5510670_S - 3 nos/set (2) Air pipe with coupling (reserv
Bellow Kit of 04 Items for LOCO for M/s. Schneider Electric Make VCB 22 CB of Part Code. BELLOW_KIT_LOCO suitable for MEMU Coaches. OEM (or) Authorised dealers only to quote along with authorization c
PRESSURE REGULATOR PARKER -14R113F for M/s. Schneider Electric Make VCB 22 CB of Part Code No. VDRM00036-01_S suitable for MEMU Coaches. Makes/Brands: M/s. Schneider Electric Only. Note: 1) The firm s
Set of items for schneider electric make 25KV VCB consists of 03 items 1) Air Pipe with coupling (Reservoir to Regulator) as per part code no: NPRM5510670_S 2) Air Pipe with coupling (Reservoir to Rel
AOH Replacement Kit for Single bottle VCB Type-22 CB of M/s. Schneider Electric Infrastructure Ltd as per Part No. NPSF 5510740-S as per attached document. Accepted part No. : Part Numbers against k.
AIR PRESSURE REGULATOR FOR SCHNEIDER VCB CONSISTS OF 1/4 INCH AIR REGULATOR, BRACKET, REAR ADAPTOR AND EXTERNAL GUAGE.0-0.1 Mpa, PART No: R1000-08-W. MAKE: CKD ONLY.. Firm's offer / Make Brand - CKD
AIR PRESSURE REGULATOR FOR SCHNEIDER VCB CONSISTS OF 1/4 INCH AIR REGULATOR, BRACKET, REAR ADAPTOR AND EXTERNAL GUAGE.0-0.1 Mpa, PART No: R1000-08-W. MAKE: CKD ONLY.. Firm's Offer: Make/ Brand : - CK
Set of MCB as per IS : 8828-1996, IEC 898-1995. Breaking capacity 10 KA. 240-415V AC 50 Hz with extendedterminals DIN type Make- HAVELLS/HAGER/ LEGRAND/ SCHNEIDER/ SIEMENS/ ABB/ L & T [Larsen and Turbo]/Control and Switch Gear [C&S]/ CGL. One set consisting the following.(1) MCB (Single Pole) 10 Amps - 5 Nos.(2) MCB(Single pole) 15 Amps - 1 No. (3) MCB (Single Pole) 35 Amps - 2 Nos.
Set of MCB as per IS : 8828-1996, IEC 898-1995. Breaking capacity 10 KA. 240- 415V AC 50 Hz with extendedterminals DIN type Make- HAVELLS/HAGER/ LEGRAND/ SCHNEIDER/ SIEMENS/ ABB/ L & T [Larsen and Turbo]/Control and Switch Gear [C&S]/ CGL. One set consisting the following.(1) MCB (Single Pole) 10 Amps - 5 Nos.(2) MCB(Single pole) 15 Amps - 1 No. (3) MCB (Single Pole) 35 Amps - 2 Nos.
Set of MCB as per IS : 8828-1996, IEC 898-1995. Breaking capacity 10 KA. 240-415V AC 50 Hz with extendedterminals DIN type Make- HAVELLS/HAGER/ LEGRAND/ SCHNEIDER/ SIEMENS/ ABB/ L & T [Larsen and Turbo]/Control and Switch Gear [C&S]/ CGL. One set consisting the following.(1) MCB (Single Pole) 10 Amps - 5 Nos.(2) MCB(Single pole) 15 Amps - 1 No. (3) MCB (Single Pole) 35 Amps - 2 Nos.
Set of MCB as per IS : 8828-1996, IEC 898-1995. Breaking capacity 10 KA. 240- 415V AC 50 Hz with extendedterminals DIN type Make- HAVELLS/HAGER/ LEGRAND/ SCHNEIDER/ SIEMENS/ ABB/ L & T [Larsen and Turbo]/Control and Switch Gear [C&S]/ CGL. One set consisting the following.(1) MCB (Single Pole) 10 Amps - 5 Nos.(2) MCB(Single pole) 15 Amps - 1 No. (3) MCB (Single Pole) 35 Amps - 2 Nos.
Set of MCB as per IS : 8828-1996, IEC 898-1995. Breaking capacity 10 KA. 240-415V AC 50 Hz with extendedterminals DIN type Make- HAVELLS/HAGER/ LEGRAND/ SCHNEIDER/ SIEMENS/ ABB/ L & T [Larsen and Turbo]/Control and Switch Gear [C&S]/ CGL. One set consisting the following.(1) MCB (Single Pole) 10 Amps - 5 Nos.(2) MCB(Single pole) 15 Amps - 1 No. (3) MCB (Single Pole) 35 Amps - 2 Nos.
NAME OF THE WORK: Erection, testing and commissioning of 1No.12.5MVA Additional PTR to the existing 1X12.5+1X8 MVA PTRs thus making total PTR capacity of 2X12.5+1X8MVA along with erection, testing and commissioning of 5Nos 11KV Feeder Indoor Switch Gear...
Supply, delivery, fixing, testing and trail run of 20 HP inline booster on 150mm and 100mm dia distribution lines with a range of 40metres head and to discharge 28 LPS along with new 415 volts 50 HZ control switch gear panel board for operating above pump set, MS chamber MS Suction, delivery connections Opp. to H.No.19-2-11/21 Bander Bowli Misrigunj under Electrical and Mechanical section, EAM Cell-IV of O&M Dn.I
Set of MCB as per IS : 8828-1996, IEC 898-1995. Breaking capacity 10 KA. 240-415V AC 50 Hz with extendedterminals DIN type Make- HAVELLS/HAGER/ LEGRAND/ SCHNEIDER/ SIEMENS/ ABB/ L & T [Larsen and Turbo]/Control and Switch Gear [C&S]/ CGL. One set consisting the following.(1) MCB (Single Pole) 10 Amps - 5 Nos.(2) MCB(Single pole) 15 Amps - 1 No. (3) MCB (Single Pole) 35 Amps - 2 Nos.
Renovation, painting and new AB switch transformer yard in Electrical substation as per CEIG, 400amps MCCB, repairs to 300mm NRV and 36 watts LED fittings in 170 HP pump house Financial District, Gachibowli, under Electrical & Mechanical Section, O&M Dn-XV.
Bellow Kit of 04 Items for LOCO for M/s. Schneider Electric Make VCB 22 CB of Part Code. BELLOW_KIT_LOCO as per ANNEXURE-I suitable for MEMU Coaches. Makes/Brands: M/s. Schneider Electric Only. Note:
POH Replacement kit for Single bottle VCB of Schneider Electric type 22 CB as per M/s Schneider Electric Part No. 5510760 as per RDSO SMI No. ELRS/SMI/0236 suitable for MEMU Coaches. Makes: Schneider
Filter regulator with metal bowl, bolt and washer as per part No. W2000-10-W-M1 of M/s CKD make suitable for M/s AAL make Single Bottle VCB. Make: CKD only. Accepted make: CKD
Magnet valve Assembly ROTEX:3486 for M/s. Schneider Electric Make VCB 22 CB of Part Code No. VDRM00150-01 suitable for MEMU Coaches. Makes/Brands: M/s. Schneider Electric Only. Note: 1) The firm shoul
Set of items for schneider electric make 25KV VCB consists of 02 items 1) Assembly details for air pipe (Fil to Con) as per part code no: NPSF5510250_S 2) Air Pipe with coupling (regulator to Filter)
IOH Kit for M/s Rotex make EP Valve of Model No. 3327 for M/s AAL make VCB consisting of 16 items Each set consist of sixteen items as per attached document. Make Brand :Rotex
Supply, delivery and fixing of 2 Nos 30HP 3phase 415 Volts Lubi make open well submerible pump set for online distribution on 150mm dia pipe line with 150mm dia check valves and sluice valves with control panel board cables , MS hoist, MS Suction and delivery connections at Vigyanpuri Section Pump House under Electrical and Mechanical Section, EAM Cell-V O and M Division-V. (1st Call)
Supply of 200W LED flood light & 40W LED light Luminaries for Outdoor Lighting of SLBHES (Intake, Exit, Surge, DG Set, OD Yard and PAT Entrance Locations and 20W,4 Ft, Industrial Purpose LED tube lights for LT & HT Switchgear & lighting section of the power house at SLBHES
HT VCBs for 20 TPH Boiler
Supply, Testing and Commissioning of New 12 Mtrs High Mast Poles, 250W LED Flood Lights, Feeder pillars Boxes, Cables and Brand Wall Elevation Lighting at HMDA Grounds (Reserved for ST)
Providing of 200 No's Temporary Lighting arrangements at immersion ponds of Maruthinagar Excavation Pond(150 No.s) in Shaikpet Division & Ready made tank, Opp: ACB office, NBT Nagar(50 No.s) in Banjarahills Division in Jubileehills Circle-18, KZ, GHMC for 11 davs in view of Ganesh immersion Sept-2022.
Supply, delivery and fixing of 800A, 4 Pole, 50 KA Electrically Drawout ACB outdoor New Panel, 400 sqmm UG cable laying and connections and other accessories etc at HSPH Sub-Station controlling power supply panel under Electrical and Mechanical Section, EAM Cell V, O and M Division No.VII.
Supply, Installation, Commissioning & Testing of Spindle Motor with VFD and Switchgear on Precision
BIFURCATION OF 11KV MILITARY-I FEEDER EMANATING FROM 33/11KV IBRAHIMBAGH SS BY STRINGING OF 1.9KM AB CABLE AND ERECTION OF 11KV VCB IN OPERATION NARSINGI SECTION OF IBRAHIMBAGH SUB DIVISION IN IBRAHIMBAGH DIVISION OF CYBERCITY CIRCLE
AOH replacement kit for New 22CB VCB of M/s. Schneider Electric Make with Part Code No. MFR38245 as per Annexure 1 suitable for New 3 phase EMU/ MEMU Coaches. Makes/Brands: M/s. Schneider Electric Onl
AOH Replacement Kit for M/s. Schneider Electric Make VCB 22 CB of Part No. NPSF5510740_S consisting of 15 Items as per RDSO SMI No. ELRS/SMI/0236 suitable for MEMU Coaches. Makes/Brands: M/s. Schneid
PAC Item: IOH Replacement Kit for M/s. Schneider Electric Make VCB 22 CB of Part No. NPSF5510750_S consisting of 14 Items as per RDSO SMI No. ELRS/SMI/0236 OR latest suitable for MEMU Coaches. Makes
Motor limit Switch (3 No+3 NC) with crank for 25 KV VCB Alind type VSE/5/20. Suitable for Alind make vacuum circuit breaker or similar. Make -OEM(ALIND) or their authorised dealers having current auth
Air pressure regulator for Schneider VCB consist of 1/4 inch Air Regulator with inbuilt Gauge, Rear adaptor and bracket. Make: CKD only. {As per agenda of MSG No. 2654526/2024/O/o PED/TRACTION/RDSO as
Construction of lift well at Block No.M8, ACB Building, Manoranjan Complex, M.J. Road, Hyderabad
Carrying out Expansion and Revamping of S and D building for accommodating control panels of S and D automation and other Maint and safety systems at Thimmapur BP
Maintenance of 30.50 MLD Filtration Plant, Replacement and Repair of Sluice Valves, Non-Return Valves, Alum Motors and Control Panels at Ramreddygudem Filtration Plant in Mahabubnagar Municipal Corporation
Construction of District Police Office Building (Balance work), Main Gate, Security Room, Front Side Compound Wall and Internal BT Roads to the Complex at Asifabad of Komurambheem Asifabad District. Sub work: Providing External Electrification with ... HT/ LT Panel boards, ...
Construction of New Police Commissionerate Building at Warangal of Warangal District. (Balance work) Sub work: Providing External Electrification with 11kV/433V 315KVA DTR including Switch Yard, HT/LT Panel boards, HT/LT Cables and SITC of 125KVA DG Set with AMF Panel, few Street lighting, few Inverter Cassette & Split ACs and SITC of 16 Passenger Lift - 1 No etc., to the New Police Commissionerate Building at Warangal of Warangal District. (STN)
Construction of District Police Office Building (Balance work) including Electrical arrangements, Main Gate, Security Room, Front Side Compound Wall to the Complex at Gadwal of Jogulamba Gadwal District. Sub work: Providing External Electrification ... HT/ LT Panel boards, ...
Supply, delivery, fixing, testing and trail run of 5 HP inline booster for 150/100mm dia distributiion lines with a range of 12 meters head & to discharge 14 LPS along with new 415 Volts, 50 Hz Control Switch gear panel board for operating above pump set, MS chamber, MS suction, delivery connections at H.No.22-1-338, Opposite Amer Manzil Function Hall, Sultanpura, Noor Khan Bazar under EAM section, EAM Cell-IV of O&M Dn.I
Supply, delivery, fixing, testing and trial run of 30HP Inline booster for 250mm dia distribution line with a range of 16m to 43m meters head and to discharge 46.3 LPS along with new 415 volts 50 Hz control switch gear panel board for operating above pump set, MS chamber, MS suction, delivery connections at H.No.18-7-425/86/53, Siddiq Nagar, Talab Katta under Electrical and Mechanical section, EAM Cell-IV of O&M Div.II
JNLIS - Overhauling of 11 Kv SF6 1600 amp 1250 amp breaker make: ABB and 11 Kv VCB 1600 amp 1250 amp breaker make: BHEL of JNLIS Stage-II pumping stations near Relampadu village, Dharur mandal, Jogulamba Gadwal district.
Set of two items (CKD make) as given below: (1) 3/8 Air filter regulator with metal bowl & gauge: CKD make, 0 to 0.1 Mpa with suitable Input bolt for old model VCB/Output bolts & their related washers
PAC Item: POH Replacement Kit for M/s. Schneider Electric Make New VCB 22 CB of Part No. MFR38248 as per RDSO SMI No. ELRS/SMI/0236 suitable for MEMU Coaches. Makes/Brands: M/s. Schneider Electric O
Closing Coil part no. CC/E for 25KV outdoor Single pole Alind VCB Type VSE 5/20, CM type BLR 80 ME. Suitable for ALIND make vacuum circuit breaker. Item testing reports required from any Govt./ NABL a
Set of two items (CKD make) as given below: (1) 3/8" Air filter regulator with metal bowl & gauge: CKD make, 0 to 0.1 Mpa with suitable Input bolt for old model VCB/Output bolts & their related washe
EMD-Servicing of M/s C and S make Air Circuit Breakers (ACBs) ranging from 630A to 4000A of LT switchgear pertaining to LT BOP and LT Main Plant/EMD/stage-II during the year 2025-26 or from the actual date of utilization from 01.04.2025 to 31.03.2026