Supply, delivery, commissioning, testing and trial run of 1 no 75HP (55.95 KW) horizontal spilt case centrifugal pump set to discharge 120-150 LPS at a head of 22-26 mtrs (as per site condition) DI control valves, MS specials along with new automatic ... control switch gear panel ...
Supply, delivery, commissioning, testing and trial run of 30HP open well submersible inline booster for 200mm dia distribution line with a range of 24mtrs head and to discharge 62.5 LPS along with 415 volts 50Hz control switch gear panel board for operationg above pump set, MS chamber, MS suction, delivery connections at safdar nagar, E-block for pumping water to safdar nagar basthi and its surrounding areas under Electrical and Mechanical section, sub Division II, O and M Division IX. Ward No.116-Allapur.
Supply, delivery, commissioning, testing and trial run of 2 Nos,15HP open well submersible pump sets to disccharge a maximum of 110 Cum/Hr at a head of 25 mtrs in place of old and inefficient pumps and new 415 volts 50 Hz control switch gear panel board for operating 2 Nos above pump sets along with delivery MS line arrangments control valves, power cable and other necessary accessories at MCH Colony pump house, Malakpet under Electrical and Mechanical section, EAM Cell-IV of O&M Dn.II
Part-A: Electrical Renovation including providing ACs for office rooms (220, 203, 115, etc) and Toilets in NIGST Blocks and Security Rooms at SOI Campus, Uppal, Hyderabad. Part-B: Shifting and Re-installation of Existing 200 KVA UPS, Batteries, ... Batteries, Electrical panels and ...
Environmental cooling towers, Copper pipe 0.875 inch size set with foam rapping, Water drain pipe 0.875 inch, Aluminium armord cable 50 sqm 4 core, 100 Amps 4 pole bus bar set, MCB 63 Amps, DB boxes, Onload 400 Amps changeover, Feeder pillar box with ... Amps MCCB , ...
Providing arrangements to draw surface water from Himayathsagar to 10 MGD Mir-Alam Filter Beds by supply, delivery and fixing of 12 ton capacity pontoon, MS pipes, rubber flexible hope pipes, valves, electrical panel boards, cables etc., erection,testing, and commissioning of 2 nos of existing 150HP/110 KW submerged centrifugal pump sets, Manning Operation and Maintenance (MoM) at Himayathsagar Earth dam, under EAM Section, SD-II, O&MDivision No.XVII,Himayathsagar
REPAIRS AND MAINTENANCE OF PUMP MOTORS, INCLUDING ITS SPARES, OCBs AND ELECTRICAL INSTALLATIONS RANGING FROM 25 HP TO 250 HP AND INSTALLATION OF PUMP HOUSE CONTROL PANELS OF VARIOUS PUMPING STATIONS OF SECUNDERABAD CANTONMENT
REPAIRS AND MAINTENANCE OF PUMP MOTORS, INCLUDING ITS SPARES, OCBs and ELECTRICAL INSTALLATIONS RANGING FROM 25 HP TO 250 HP AND INSTALLATION OF PUMP HOUSE CONTROL PANELS OF VARIOUS PUMPING STATIONS OF SECUNDERABAD CANTONMENT
REPAIRS AND MAINTENANCE OF PUMP MOTORS, INCLUDING ITS SPARES, OCB AND ELECTRICAL INSTALLATIONS RANGING FROM 25 HP TO 250 HP AND INSTALLATION OF PUMP HOUSE CONTROL PANELS OF VARIOUS PUMPING STATIONS OF SECUNDERABAD CANTONMENT
Remove, Shifting, commissioing, Testing and Trial Run of 1 Nos.26KW/35 HP Sewage pumpsets from Somajiguda to 20 MLD Pump room with to discharge of 400M3/ HR (111LPS) at 17 Meters head for improvement of existing sewage pump disposal, along with ... with control panel board, ...
Supply, delivery, erection and commissioning of 50HP/37 KW HSCC pump set of Kirloskar make model No. 125/35 to discharge 90 LPS at a head of 27 mtrs along with control panel board for operation of 2 Nos 50HP pump set and suction and delivery line arrangement with sluice valves non-return valves and other accessories at Hari Nagar Pump House under Electrical and Mechanical Section, EAM Cell-V O and M Division-V. (1st Call)
Contact Resistance Meter, Time Interval Meter, Test Leads For MCCB, Pocket Size Voltage Detector
TGGENCO-YTPS (5X800 MW)-BOP-II-Preventive electrical maintenance works related to LT Switchgear, Dry type Transformers, and NSPBDS, LT Board like, PMMC and MCC, LT motors upto 110 KW and 3.3 KV H.T Motors upto 450 KW in BOP area from 01.04.2026 or from the actual date of commencement of work to 31.03.2027 for F.Y 2026-2027.
Providing Electrical Installation with necessary control Switchgear, LAN Networking and IP based EPABX system and accessories to newly proposed New filing section over Judges car Garrage, High Court, Hyderabad. Sub work: Providing Additional Electrical installations, LAN Networking to the Digitalization wing and e-filing wing at newly proposed New Filing section over Judges Car Garrage, High Court, Hyderabad
Refurbishment of existing 6.6KV VCB panels of PTR-1 and PTR-2 along with removal and diversion of incoming and outgoing HT cables from the existing panel room to the extended panel room at 132/6.6KV Godakondla substation under EAM section, SD-IV, Transmission Div.III, Sahebnagar
Construction of District Police Office Building (Balance Work), Main gate, Security room, Front side Compound wall and internal BT roads to the complex at Medak of Medak District. Sub work: Providing External Electrification with 11kV/433V 500KVA DTR ... HT/ LT Panel boards, ...
Providing External Electrification, Street Lighting with LEDs and DG supply (Stand by supply) for OCTOPUS Commando Training center at Ibrahimpatnam of RR District. Sub-work: Providing External Electrification with 11kV/433V 315KVA DTR, 160KVA DTRs ... HT/ LT Panel boards, ...
Supply of duly wired, non- compartmental type MCC cum PLC control panel with PLC system, The installation and commissioning of the supplied new Non- compartmental type MCC cum PLC control
Autoclave preesurization control value, Autoclave drpreesurization control valve, Autoclave vacuum control valve, Autoclave vent valve, Autoclave vacuum receiver valve, Sine wave inverter for control panel, Thermocouple sensor 100 meter length
Erection of 11KV Dedicated feeder by erecting a feeder VCB at 33/11KV Medikunda SS to M/s. Executive Engineer TDWSP (SC.No.SGR-2431) under HT Cat-IV (B) at 11KV Supply at SY.No.11/20 at Gorrekal(V) in Vatpally Section of Jogipet Division in Sangareddy Circle
Refurbishment of existing 6.6KV VCB panels of PTR-1 and PTR-2 along with removal and diversion of incoming and outgoing HT cables from the existing panel room to the extended panel room at 132/6.6KV Nasarlapally substation under EAM section, SD-IV, Transmission Div.III, Sahebnagar.
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including existing 4 no of 3150KVA power transformers, electrical panels, cables, 33KV Over head line and all allied electrical equipement to feed the power supply to emergency pumping arrangements at foreshore of Nagarjuna Sagar near Puttamgandi including 4 months MoM for Substation,dismantling and transportation of all equipment to Kodandapur, Nasarlapally and Godakondla whenever sufficient inflows started to Nagarjunasagar reservoir, under EAM Section, Electrical Sub division, O&M Division-XI, Sahebnagar.
Supply,Delivery, Commissioning and testing of 3 Phase, 11KV/0.433 KV,50Hz, 100KVA copper wound, oil cooled out door distribution tranformer, 11KV, 95Sqmm,3 phase, 4 core Aluminium armoured AB power cable, cubical control panel, 11KV, 630 Amps, 3 phase LBS (Load break switch), armoured power cables, CI earthing necessary accessories for improvement of 3 phase incoming voltage supply to the inline booster, tanker filling stations at Hydernagar campus under EAMC SD-II&III under O&M Division-XXI, Control room, Secunderabad.
Design, Engineering, Manufacture, Inspection, Delivery at destination, Installation Testing and Commissioning of 17.5 KV (for a system voltage of 13.8KV) or higher rated Indoor Air Insulated Switchgear with Vacuum Circuit breakers and Control gear along with its necessary accessories for Srisailam Left Bank Hydro Electric Scheme (SLBHES) Telangana. Make: ABB Siemens/Schneider/GE/Larsen and Toubro or any other reputed make.
Repairs and renovation of Horticulture department building to accommodate Telangana Rythu Samanvaya Samithi office at Public Gardens, Nampally, Hyderabad. Rewiring to EI, Replacement of old Electrical fittings with new fittings with required ... required switchgear and ...
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including existing 4 no of 3150KVA power transformers, electrical panels, cables, 33KV Over head line and all allied electrical equipement to feed the power supply to emergency pumping arrangements at foreshore of Nagarjuna Sagar near Puttamgandi including 3 months MoM for Sub station and dismantling and transportation of all equipment to Kodandapur, Nasarlapally and Godakondla whenever sufficient inflows started to Nagarjunasagar reservoir, under EAM Section, Sub Division-IV(Electrical), O&M Division-XI, Sahebnagar.
Operation and maintenance of 11 KV indoor substation including HT and LT switch gear in the Jyothirao Phule Praja Bhavan office cum Honble Deputy Chief Ministers residence and punjagutta section at begumpet,Hyderabad for the year 2026-2027
Power distribution panel, Earthing cable, Input and output cables harness with MIL grade connectors, 630A MCCB panel
Supply, delivery, commissioning and testing of 3 phase, 11KV/0.433 KV, 50Hz, 160KVA copper wound, oil colled outdoor distribution transformer, 11KV, 95Sqmm, 3 phase, 4 core Aliminium armoured, LT supply distribution control panel, 11KV, 630 AMps, 3 Phase LBS (Load break switch), remoured power cables, CI earthing necessary accessories for improvement of 3 phase incoming voltage supply to the inline booster, tanker filling stations at Kondapur, White Field in White Field Section of Kondapur Sub Division-I under O and M Division XV, Durgamcheruvu.
IOH KIT For Single Bottle VCB of M/s AAL Type VCBA25.10Tr mfd after Dec 2016 onward vide AAL Part No. 4300007100/62 with Festo make Pressure Regulator. 01 set of mini pack i.e IOH, I&P Kit vide AAL part no. 4300007100/75. set details as per Annexure-I (attached).
Bifurcation of 11KV NM Guda OH feeder emanating from 33/11KV Attapur SS by proposing new 11KV feeder from the same SS with laying & raising of 1.09KM of 11KV 3X185 Sq.mm. XLPE UG Cable along with erection of 11KV VCB at 33/11KV Attapur SS in Attapur Section Charminar Division
Cable Joint Kit (V2) (Q3), On-Load Changeover Switch with 4P 100A, On-Load Changeover Switch with 4P 200A, CRCA MCCB Box FP, size 75X75X50mm, 100A, CRCA MCCB Box FP, 100A, 3P IK 08, CRCA MCCB Box FP, 125A, 3P IK 08, CRCA MCCB Box FP, 160A, 3P IK 08, ... CRCA MCCB Box ...
Erection of 1No.5way RMU, 2No.s 500KVA DTRs & 3No.s Automatic Transfer switches (ATS) with laying of 400mtrs of 11KV 3x185 sq.mm XLPE UG cable for providing of automatic load transfer arrangement for TS Transco and TS Genco entire building at Vidyuth Soudha Khairtabad, Hyderabad duly extending the supply of 11KV ZP feeder emanating from 33/11KV ZPS SS in Somajiguda Section of Saifabad sub division in saifabad Division of Hyderabad Central Circle under DCW works.
Design Engineering Manufacture Inspection Delivery at destination Installation including transportation to site Testing Commissioning of 3 Ph 440 V LT Emergency Panel Board EPB for feeding essential loads including necessary switchgear for auto changeover of power supply to DG sets in case of failure of incoming supply and two numbers VFD Starters for running Submersible dewatering pumps at SLBHES Srisailam Dam West Nagar Kurnool Dist 509326 TELANGANA
Up keeping and Preventive maintenance works of HT and LT Switchgear, Oil Type Transformers, Dry Type Transformers, HT and LT Bus Ducts and Motors and LT Boards, Belt Watch Panels of the CHP YTPS related to ER2, ER3 and ER4 equipment up to TP10 in the Priority Path from actual date of commencement of work to a period of 3 months for the FY 25 26
Laying of 200mm dia MS water supply line for providing water supply connection to M/s Telugu Film Producers mutually Aided Cooperative Housing Society Pvt. Rep by Suryanarayana Sy.No.239/240, Kokapet Village, Rajendra Nagar Mandal under Osmansagar ... with Control panel board, ...
Fabrication, 3 Pole MCCB, Spider links, Bus Bar, Insulators, KWH meter, Exhaust system, Dg set dismantling assembling, Shifting, Miscellaneous
Bifurcation of 11KV Kishanbagh OH feeder emanating from 33/11KV Attapur SS by proposing new 11KV feeder from the same Substation with laying & raising of UG Cable and stringing of 600Mtrs OH line with 55sqmm AAA conductor along with erection of 11KV ... 11KV VCB at ...
(A)Laying of 200mm dia DI water supply main from Road No.3 to Trendset Builders on Road No.5,Banjara Hills under Banjara Hills Section,SD-I,O&M Div.VI.(B) Providing Manufacture,Supply,delivery,commissioning,testing and trial run 37KW/50 HP Horizontal ... main switch gear panel ...
Estimate proposal for bifurcation of New 11KV Dargh Feeder , 11KV Shanti Nagar Feeder with VCBs duly erecting 11 KV new VCBs and extension of bay extending existing 11KV bay and erection of 2Nos.11KV feeder VCB at 33/11KV Balapur Sub Station premises in Bal section of Mamidipally Sub Division of Kandukur Division of Rajendranagar Circle
MCB - Miniature Circuit-Breakers for a.c. operation - IS/IEC 60898 Part 1 (Q2), Molded Case Circuit Breakers (Mccb)- IS/IEC:60947 (Q3)
MCB - Miniature Circuit-Breakers for a.c. operation - IS/IEC 60898 Part 1 (Q2), Molded Case Circuit Breakers (Mccb)- IS/IEC:60947 (Q3)
MCB - Miniature Circuit-Breakers for a.c. operation - IS/IEC 60898 Part 1 (Q2), Molded Case Circuit Breakers (Mccb)- IS/IEC:60947 (Q3)
MCB - Miniature Circuit-Breakers for a.c. operation - IS/IEC 60898 Part 1 (Q2), Molded Case Circuit Breakers (Mccb)- IS/IEC:60947 (Q3)
SUPPLY OF 400 SQMM 3.5 CORE XLPE ALUMINIUM ARMORED CABLE (Q3), Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3)
MCB - Miniature Circuit-Breakers for a.c. operation - IS/IEC 60898 Part 1 (Q2), Molded Case Circuit Breakers (Mccb)- IS/IEC:60947 (Q3)
TGGENCO-YTPS(5X800MW)- TGGENCO- YTPS(5X800MW) - Stage-I-Maintenance Works of Unit-2 -LT switch gear of LT-2 sub division of stage-I/YTPS(5X800MW) as and when required for the FY:2026-2027 from 01.04.2026 or actual date of commencement of work to 31.03.2027
Bifurcation of 11KV Donbasco feeder emanating from 33/11KV Snehitahills Sub-Station by erection of new 11KV feeder from 33/11KV Kismathpur Sub-Station which involves laying of 1.84KM of 11KV 3X185 Sq.mm UG Cable (Single Run) along with erection of ... feeder VCB at ...
(A).Laying of 200mm dia DI water supply main from Road No.3 to Trendset Builders on Road No.5,Banjara Hills under Banjara Hills Section,SD-I,O&M Div.VI. (B).Providing Manufacture,Supply,delivery,commisioning,testing and trial run 37KW/50 HP ... main switch gear panel ...
Bifurcation of overloaded 11KV Naseeb Nagar feeder emanating from 33/11KV Kandikalgate SS by erection of new 11KV feeder from the 33/11KV Arundhati SS by laying of 0.985 KM of 11KV 3X185 Sq.mm. XLPE UG Cable along with bay extension and erection of ... 11KV VCB at ...