Loading…
Loading…
2,371 results • Best match
(Plastic Bag/Dustbins/Container/Non Releasable Cable Ties/Gumboot/Needle Destroyer/NEW Fire Extinguisher and Riffiling and Heavy Duty Hand Gloves)
as per BoQ
as per BoQ
AS PER BOQ
AS PER BoQ
as per BoQ
as per BoQ
AS PER BOQ
ok
ADN PC i7 14 gen 1TB SSD 32 GB RAM 24 Inches Screen 8 GB Graphics Card, HD Studio 360 Camera with auto zoom facility, display system data wall, Projection System, Interactive Panel 86 Inches with Touch Screen Display, CCTV System, Display Controller, ... System, Fire Alarm system ... with smoke detector
Annual rate contract for spare parts and repair work of Ashok Leyland Make fire fighting vehicles of Municipal Corporation Bikaner.
Manual Aerosol Fire - Extinguisher (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Experience Criteria, Bidder Turnover, Certificate (Requested in ATC), Additional Doc 1 (Requested in ATC), Additional Doc 2 (Requested in ATC), Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? No -- Minimum number of bids required to disable automatic bid extension 1 Bid Number : GEM/2025/B/6519578 Dated : 12-08-2025 Bid Document 1/5, -- Number of days for which Bid would be auto -- extended 7 Bid to RA enabled No Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Construction of A type School Building, Staff Quarters Type-II/ 4 nos. G1 Type-III/4 nos. G1 and Type-V/1 no. S/S Boundary wall etc for Kendriya Vidyalaya BSF Raisingh Nagar Rajasthan SH Providing and fixing shed over fire fighting pump at roof of school building extension of basket ball court post area and other misc. work
WATER DISPENSER, fire extinguisher, DIGITAL CLOCK, ANALOG CLOCK, DOOR MATE, KEY BOX, CRYSTAL GLASS, ROOM HEATER, OIL RADIATOR, REFROGRAPHIC MACHINE, OIL PAINT
Design, Engineering, Manufacturing ,Testing, Inspection, FAT, Supply , Delivery and Supervision of Installation , Prototype Test at site, SAT and Commissioning of the PLC Based Control Panels with Mandatory Spares,Commissioning Spares and Six Month
Annual contract for the work of Fire Fighting Operation of 6 x 250 MW (Unit 1 to 6) STPS RVUN Suratgarh
AS PER BoQ
as per BoQ
GALVANIZED MILD STEEL FIRE BUCKET (Fire suppression hand tools) as per IS 2546 (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, Certificate (Requested in ATC), OEM Authorization Certificate, Additional Doc 1 (Requested in ATC), Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes Past Performance 20 % Bid to RA enabled No Type of Bid Single Packet Bid Bid Number : GEM/2025/B/6333204 Dated : 12-06-2025 Bid Document 1/5 Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Addressable Multi Sensor Detectors Discovery Series With Base, Model: 58000-700, Optical Type Addressable Smoke Detector Of XP-95 Series, Model: 55000-600 APO, Addressable Heat Detectors Of XP-95 Series, Model: 55000-400 APO
Portable Fire Extinguishers (V3) ISI Marked to IS 15683 (Q2) MSE Relaxation for Years Of Experience and Turnover Yes | Complete Startup Relaxation for Years Of Experience and Turnover Yes | Complete Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Number of Auto Extension count 1 Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days Bid Number : GEM/2026/B/7075279 Dated : 06-01-2026 Bid Document 1/6 ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No
as per BoQ
as per BoQ
as per BoQ
as per BoQ
as per BoQ
as per BoQ
as per BoQ
Thermos Steel 05 Ltrs, Sintex Water Tank 500 Ltrs, Running Mat width 3 ft, Dispenser Water Bottle 20 Ltrs, Fire Extinguisher Ball with Stan
As per BOQ
Portable Fire Extinguishers (V2) ISI Marked to IS 15683 (Q2) MSE Exemption for Years Of Experience and Turnover Yes | Complete Startup Exemption for Years Of Experience and Turnover Yes | Complete Document required from seller Certificate (Requested ... Portable Fire Extinguishers (V2) ...
Modular Structure Containerised Shooting Range made of AR 500, Bullet Trap System, Anti Ricochet Treatment of Side Walls These walls will be treated with layers of bullet absorbing material, Overhead Hanging 3 to 8 inch AR 500 Steel Ceiling Baffles ... room, Fire Fighting Arrangements ... Arrangements Fire Extinguishers etc ... etc Fire Alarm Panel ... x fire extinguishers Type ...
Air conditioning worFire Protection and Detection work in A.D.R. Building and Family Court Building at Udaipurk in POCSO Courts in new court complex, Udaipur
EXTINGUISHER FIRE DEFENCE WATER STORED AIR PRESSURE TYPE OF 9 LTRS CAPACITY (STAINLESS STEEL BODY) (Q2), Portable Fire Extinguishers (V2) as per IS 15683:2018 (Q2)
Annual contract for Routine Breakdown Capital Maintenance of Fire Hydrant HVW or MVW spray system Diesel or Electrical pumps compressors etc and routine checking cleaning and minor maintenance works
SUPPLY OF AEROSOL FIRE DETECTION AND SUPPRESSION SYSTEM CARTRIDGE MINIMUM 10 GM, ACTUATING DEVICE WITH 68 - 72 DEGREE CENTIGRADE, FOR ELECTRICAL PANEL OF ICF TYPE SG NON-AC COACHES AS PER THE TECHNICAL REQUIREMENT SPECIFIED IN ANNEXURE G1 OF RDSO SPECN.RDSO/PE/SPEC/AC/0192-2018(REV.1) OR LATEST & RDSO L.No. EL/7.1.108/SBC/Main DATED 16.01.26 AND HQ/JP L.No. : EL/245/2/Mod DATED 16.01.26
Electronic Lectern, High End Desktop Computer, Multimedia Projector (MMP), Online UPS (V2), Visualizer, Mobile Jammer, Networking Switches 8x8, Fire Alarm System, CCTV System, Biometric System
Annual Contract for Operation work of firefighting system at RGTPP Ramgarh
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - THERMAL POWER PLANT; Fire Protection System pumps; Buyer
As mentioned and described in BOQ
watermist and caf fire extinguisher high pressure back pack type Watermist And Caf Fire Extinguisher High Pressure Back Pack Type ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values Genric "Conformity to EN 3-7:2004+A1:2007-0 8 standards " The complete system shall be tested for compliance from an int ernationally/nationally accredited laboratory for compliance to all 30 clauses (3.2, 3.15, 4.2, 4.3, 4.4, 4.5, 6.1, 6.2, 6.3, 7.1.1, 7.1.2, 7.2, 7.3, 7.4, 8.1, 8.2, 9.2, 10.1, 10.2, 10.3, 10.4, 10.5, 10.6.1 & 10.6.2, 14.1, 14.2, 15.2, 15.3, 16.1, 16.2) of EN 3 - 7:2004 + Al: 2007-08 (E) Standard mandatorily applicable for the complete system thecompletesystemshal lbetestedforcompliance fromaninternationallyn ationallyaccreditedlabo ratoryforcompliancetoa ll30clauses(3.23.154.24 .34.44.56.16.26.37.1.1 7.1.27.27.37.48.18.29. 210.110.210.310.410.5 10.6.1&10.6.214.114.2 15.215.316.116.2)ofen 3-72004al2007-0 Mounting type Backpack - Configuration ( Shall be mounted on a sturdy frame suitably cushioned for comfort, provided with shoulder pads for carrying as a backpack and a handle Yes - 1/6 to be carried by hand. All materials used shall be of fire retardant type. Backpack shall be supplied with two air cylinders.) Model Number as per Accredited Laboratory Test Report to Be declared ASKA HI PRESS 02-010 - Main Components: Pressure vessel to hold the media with safety valve, compressed air cylinder coupled with a reducer, hose pipes for discharge of water mist media, extinguishing gun. Yes - Constructional Air Cylinder Material Ultralight Carbon composite with PET Liner Ultralight Carbon composite with PET Liner Type of Foam Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55, B233, Spreading coefficient for special AFFF Compound shall be +5 minimum, concentration shall be 6%. Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55, concentration shall be 6%. If special foam mention the composition for special, otherwise put NA Water 96%, 1, 2-Ethandiol, Fluorinated surfactant 0.5%, Octylsulfate 1%, Decylsulfate1%, Akylpolyglycoside1% - Commercial Brand Name of the Special foam (fire extinguishing medium) as per accredited laboratory test report wherein higher fire ratings i.e A55, E1000 V (Die Electric Suitability) achieved, to be declared.Write NA if not applicable. ASKA FX AGENT - Characteristics of extinguishing medium of Special AFFF Density 1.12, Viscosity 2.0, pH factor 8.5, Refractive index 1.3692 - 2/6 Compound (manufacturer own specifications) with infrared spectrogram to be furnished.NA if not applicable at 20 ± 2deg C Pressure Vessel Material & Capacity (Nominal Charge) Corrosion Free Aluminum alloy vessel of 10 litre capacity . Corrosion Free Aluminum alloy vessel of 10 litre capacity . Minimum wall thickness of pressure vessel (mm) 5.0 - Extinguishing gun material Stainless Steel - if others Mentions the material for Extinguishing gun, otherwise put NA na - Extinguishing gun weight (750 grams approx) 750.0 - Length of EN marked Hose 1.3 meter for backpack system Yes - Weight of fully charged Backpack system between 25kg to 27kg having Corrosion Free Aluminum Alloy vessel and below 20 kg having Ultralite Carbon Composite with PET Liner Vessel for 25.9 - performance Air Cylinder Capacity (Ltrs) 2.0 - Air Cylinder pressure (Bar) 300.0 - High Pressure Type (Dynamic Operating pressure to be tested in the accredited laboratory test report which will be considered as high pressure for as per clause No. 3.15 of EN 3 - 7:2004 + Al: 2007-08 (E) Standard.) ≥ 30 for Aluminium vessel, ≥ 35 for Ultralight Carbon composite with PET Liner vessel (Bar) 30.0 - 3/6 Lancing Distance of Gun : More than 12 meter (meter) 12.0 - The air hoses shall be suitable for minus 40 deg C to 100 Deg C temperature and EN mark on hose Yes - Minimum operating time in full throttle for aluminium alloy vessel 22 - Minimum operating time in full throttle for Ultralight Carbon composite with PET Liner vessel na - System shall be designed for maximum operating temperature TS max and minimum operating temperature TS min of 60 deg C or more and 5 Deg C or less respectively and certified by the manufacturer accordingly as per Clause 7.4 of EN 3-7:2004+A1:2007-08 standards as per the accredited test report for backpack system. Yes - Fire Rating 55 A, 233B, 1000V with Special AFFF Compound as per manufacturer own specn 55 A, 1000V with Special AFFF Compound as per manufacturer own specn Certification PED approval as per Directive 97/23/EC Yes - Pressure Vessel shall include a pressure gauge fitted on the vessel (CE Marked from notified body). Yes - No objection certificate (NOC) for Pressure Vessel from Petroleum and Explosives Safety Organization (PESO) Nagpur Yes - Pressure Vessel should have CE Marking from Yes - 4/6 Notified body The air cylinders shall have PESO, Nagpur approval yes - Specific consent of the OEM for the value additions made along with a confirmation that fire ratings of the equipment would not be affected by these value additions. Yes - Test Report No - - Test Report Date - - Name of ILAC/NABL/Central Govt.Accredited Laboratory where Test Conducted - - NOC Letter No. Date of PESO Nagpur for Pressure Vessel - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Om Prakash Palasia 305001, Diesel, Loco and Wagon Workshop, NWR, Ajmer 2 15
Portable Fire Extinguishers (V2) as per IS 15683:2018 (Q2) MSE Exemption for Years Of Experience and Turnover Yes Startup Exemption for Years Of Experience and Turnover Yes Document required from seller Additional Doc 1 (Requested in ATC) *In case ... Portable Fire Extinguishers (V2) ...
Co2 Based Wheeled Fire Extinguishers (V2) ISI Marked to IS 16018 (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No Document required from seller Additional Doc 1 (Requested in ATC), ... Wheeled Fire Extinguishers (V2) ...
Portable Fire Extinguishers (V2) ISI Marked to IS 15683 (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Experience Criteria, Past Performance, Bidder Turnover, Certificate (Requested in ATC), OEM Authorization Certificate, Additional Doc 1 (Requested in ATC), Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 1 Bid Number : GEM/2025/B/6775968 Dated : 10-10-2025 Bid Document 1/7, -- Number of days for which Bid would be auto -- extended 3 Number of Auto Extension count 1 Past Performance 10 % Bid to RA enabled No Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No
Video Conferencing Camera/Web Camera (V2), Online UPS (?10 KVA) With Battery Conforming To IS 16242 (Part 1), Slide Presenter, Touch enabled display, Fire alarm system
STUDENT BENCH ATTACHED CHAIR AND TABLE, WHITE BOARD 3 BY 4, ALMIRAH 3 BY 6, FIRE FIGHTING EQPT, OUTDOOR MULTI SWING SET, CONSTR OF MAIN GATE
NFC KOTA TOWNSHIP CONSTRUCTION OF DISPENSARY, EM OFFICE, SCHOOL INCLUDING CIVIL, PH, INTERNAL ELECTRICAL AND FIRE FIGHTING WORKS FOR NUCLEAR FUEL COMPLEX TOWNSHIP AT RAWATBHATA, RAJASTHAN.
Comprehensive Architectural and Engineering Consultancy Services for Civil, Electrical, Mechanical, Plumbing ,fire fighting and All other allied Works for Providing Comprehensive Design and Engineering Consultancy Services
as per BoQ
Crash Rated Automatic Sliding Gate, Automatic Modular Fire Extinguisher 5 Ltr, Hydraulic Tyre Killer 6 Mtrs, Security Light Solar Type, Speed Breaker 6 Mtrs, Door Frame Metal Detector