Loading…
Loading…
8,185 results • Best match
Supply, installation, commissioning, testing of 03 nos. 3.3KV NGRs with fail safe relay with two years extended guarantee for three nos. 3MVA, 6.6KV/3.3KV transformers installed at 2X12.5MVA, 33KV/6.6KV Main substation of Rajrappa Project
Repair and maintenance and diversion of 11KV O/H line Feeder No-4 near Jamunia Halt and repairing of burnt horn gap fuse and AB switch at Damoda workshop and Albion substation of Damoda Colliery.
Complete repairing and maintenance of overhead line 6.6KV 3 phase from Sudamdih 33KV substation of Sudamdih Railway siding feeding for siding lighting and 6.6KV by 440V and 6.6KV overhead line of panel no 11 6.6K
Complete Repairing of 400 Amps 11 KV grade VCB switch make Electroteknica for primary controlling switch of 3.15 MVA transformer Sl. No.SGI-2312 at new KT substation of jeenagora under Amal. NT-ST-JG Colliery.
Onsite repairing/modification of one no. Control Panel 440 Volt for control n monitoring of circuit breakers for control of different feeder installed at 11 kV Main Substation, D.D. Mines, Bokaro Colliery, under BnK Area.
Testing of 33KV CTS and 6.6KV CTS by Primary injection set for relays effectiveness testing and also issue test certificate for records at Sudamdih Regional Substation 33KV 6.6KV under ASP Shaft Colliery E. J. Area.
ERECTION OF 440 VOLT L.T. OVER HEAD LINE FROM TETULMARI SUBSTATION TO NEAR AREA OFFICE AND ALSO ERECTIONOF 2 SPAN 440 VOLT OVER HEAD LINE FOR NEW PUMPHOUSE AT NEW AREA OFFICE UNDER KATRAS AREA.
Providing ,fitting and commissioningof E/L relay,digital Ampmeter and under voltage relay with repairing/maint.of indoor isolators of indoor 6.6 kv panels of Reginal substation (33kv/6.6KV) shaft SMD of Amalgamated Sudamdih Patherdih Colliery
Repairing / rewinding of 250 KVA (3.3KV / 550 Volt/440 volt) FLP Trans switch Unit, Sl. No.04/9/146, make- Andrew Yule, installed at Ray Substation under Bachra Township Control of GM unit, Piparwar Area.
Dismantling of idle 11KV O/H line from NICCO Plant to MOCP substation and erection of 3.3KV O/H line for power supply to 4000GPM pump motor set at Jarlahi face under Muraidih, AMP Colliery.
Repair and maintenance of HT OH line (3.3KV) from Ambedkar colony BaluBanker substation for operation of pump related with water supply at Balu Banker and its adjucent colonies at riverside under GM Unit, Dhori Area.
Distinguishing, strengthening and earth continuing of both incoming mines feeders from Gandhinagar substation to DD Mines and fencing of 11 kV pole at GVTC as pointed out by DDMS (Electrical) in respect of Bokaro Colliery
Complete repairing of 3.3 KV VCB Switch 800 Amp. Outdoor type make Andrew Yule Sl. No. 1359 installed at Rohini Main Substation for secondary control of 3MVA Transformer in respect of Rohini Project, NK Area
Repairing and maintenance of 33KV Parbatpur Substation by supply and fitting of Control cable cable jointing post insulator and light fitting of mine premises Area at Parbatpur Central Coal Mine under BCCL, E. J. Area.
Arrangement of lighting arrester, new earth pits construction and connection by cu wire etc. for protection of electrical equipment and wiring of 02 newly constructed room at Banwar substation of Topa OCP under Kuju Area.
Repairing and maintenance of 6.6 KV OIH line due to heavy rain and thundering in O/H line and erection of tilted poles from shatabdi substation to Jarlahi pump site under AMP Colliery, Barora Area.
Shifting of existing substation of Tapin South OCP 11KV/3.3KV comprising of Station Transformer, Bus-bar system 11KV/3.3KV, 11KV overhead line re-organization, interlocking arrangement, sky netting for protection from lightning, remote control system
Erection, making of temporary shed for Capacitor bank with electrical 3.3KV and 3.3KV/440V, 100KVA transformer for power segregation to colony and mine in mines feeder at main substation of Pindra Project under Kuju Area
Shifting of 3.3 KV Capacitor Bank with Control Panels and Shed Foundation, making of trench and 11 KV GOAB Structure for support of Bus Bar at main substation 2X3 MVA of PEOCP under Hazaribag Area
Supply and fitting of bimetallic clamp, pipe to conductor clamp, aluminium (T-type) and PG clamp for dog or wolf conductor for different power transformer and power controlling switches at regional substation under Kathara Colliery.
Onsite supply and Installation of digital energy meter with HT Current Transformer for monitoring of energy demand analysis of different feeder for mines , pumping and colony at 33 kV main substation AKKOCP under BnK Area
Painting of pole, Bus-bar structure and supply and fixing of Danger board anti-climbing device on pole and structure installed at MURPA Substation and GM Unit overhead line under GM Unit of Kuju area.
Repairing of OCB Switch of Make Kilburn, 200A, 550/440V, Type SD-15, Sl. No. 8566 to be installed at the Secondary side of the trasnformer of 5 Pit Substation of NAKC under Govindpur Area.
Repair cum maintenance of the 3.3 kV and 11 kV Gang Operated A.B. Switches, including its accessories for its installation, installed in Mine, Workshop and the 11 kV Main Substation, under Karo OCP, BnK Area
Repair cum maintenance of the 3.3 kV and 11 kV Gang Operated A.B. Switches, including its accessories for its installation, installed in Mine, Workshop and the 11 kV Main Substation, under Karo OCP, BnK Area.
Hiring of 01 no mini truck or equivalent for carrying out day to day line/Substation Maintenance work under GOMD III DVC Jamshedpur for a period of 02 Year from the actual date of commencement.
work for PCC and metal laying spreading in complete 33KV Switchyard area at GSS Itkhori
Annual rate contract for various maintenance activities of 400KV Switchyard, KTPS, DVC for 02 years
MOE and MI in non-residential building of DGMS at Dhanbad. (SH: Providing day to day maintenance of internal EI and fans, compound lights and running operation maintenance of water pump sets, DG sets and substation equipment in non-residential ... and substation equipment
For Maintenance and Repairing of 6.6KV Overhead line from(a) 7/8 Substation to west chandor and MAP-3 Substation(b) from 7/8 Substation to HT Pump 4 Seam,TMC
Construction of A Type two sections school building G Plus 2 4 Nos. Type II Qtrs. G Plus 1 4 Nos. type III Qtrs. G Plus 1 01 no. Type V Qtr. Canteen Electrical substation Pump room Underground sump Boundary walls along with Gates and Guard room ... Networking Substation Equipment ...
Construction of A Type two sections school building G plus 2, 4 Nos., Type-II Qtrs. G plus 1, 4 Nos., Type-III Qtrs. G plus 1, 01 No. Type-V Qtr., Canteen, Electrical substation, Pump room, Underground sump, Boundary walls along with Gates & Guard ... Networking, substation Equipment ...
Construction of A Type two sections school Building G plus 2 4 Nos Type II Qtrs G plus 1 4 Nos Type III Qtrs G plus 1 01 No Type V Qtr Canteen Electrical substation pump room Underground sump Boundary walls along with Gates and Guard room including ... Networking Substation Equipment ...
Construction of A Type two sections school Building G plus 2 4 Nos Type II Qtrs G plus 1 4 Nos Type III Qtrs G plus 1 01 Nos Type V Qtr Canteen Electrical substation pump room, underground sump boundary walls along with Gates and Guard room including ... Networking substation Equipment ...
Construction of A Type two sections School building G plus 2, 4 Nos. Type-II Qtrs. G plus 1, 4 Nos. Type-III Qtrs. G plus 1, 01 No. Type-V Qtrs., Canteen, Electrical substation, pump room, Underground sump, boundary walls along with gates and Guard ... Networking, substation equipment ...
Repairing of O/H line of 11 KV feeder No,3 6.6 KV D/L Feeder S-1 Feeder, Starting pole of M-1,M-2 and Feeder No,.16 and cable work at incomer of various panels, along with 33KV switchyard main. At Madhuban DG Sub-stn. Under Block-II Area
Towards repairing of OCB, 550V,400A Sl.No.BSE-384 Make Rayroll at Coke Plant Substation of Loyabad Colliery(ii) and Repairing of 440V 1000Amps ACB make ABC Electricals Pvt.Ltd.Sl.No.397 along with 60HP 100Amps Starter installed at NPTS
For complete repairing/rewinding of Transformer 315KVA,6.6KV/440V Sl.No.160A Make Marson at MDC(ii)Complete repairing/rewinding of lighting Transformer 300KVA,6.6KV/440V Sr.No.Tr.133 at Tetulmari Patch A substation of Mudidih Colliery
Providing and Installation of 10 nos. LOTO System at 33KV/11KV Substation and Saunda Siding substation under Urimari OCP.
For Repairing of AB switch, fitting of lighting arrestors, cable compounding, installation of earth pit etc. Tetulmari Sub-Stations. (b) For Supply and Installation of 02 nos. Chemical E
Work of Supply of outsource manpower for operation work of 132/33KV, Grid Sub-Stations under Transmission Division, Gumla for the financial year 2026-27 w.e.f. 01.06.2026 to 31.03.2027.
Tree trimming including cutting of branches and uprooting vines near33KV/11KV/3.3KV incoming O/H power line from 33KV substation to 11KV substation till tilaiyya village via Potanga substation under Urimari OCP.
Cleaning and painting , naming of all switches and transformer, painting of all bus bar structure and foundation of switches/transformer fluorescent strip in all bus bar pole at 2MVA,11KV/3.3KV Main substation of kuju colliery.
Diversion of 3point3 KV overhead line from Ganeshpur substation to main patch and erection and installation of 220volt lighting line overhead for peripherical lighting of pump site at main patch of Phularitand OCP in Phularitand Colliery
Providing and fitting of control wiring of power bank of two switches of 3point3KV 400amps VCB Andrew yule make switch and 11KV 800amps OCB switch GEC make controlling of fire area workshop substation of Damoda Colliery
Onsite cleaning, Servicing of 3MVA, 11KV/3.3KV oil filled transformer including body, tank, valve, explosive vent, fins, core and winding installed at Gandhinagar Substation and Onsite electrical repair of four (04) nos. Oil cooled Distribution Trans
Towards repairing and maintenance of overhead lines containing power supply 550V at different location under LBC(ii) replacement of lighting O/H line for installation from substation NPTS CISF Centre under Nichitpur Township under Sijua Area
For testing of breaker, Starter, Motor, Transformer and overhead line primary, secondary injection, High pressure(HV), insulation, Dielectric strength, acidity test and flash point test for also issuing test certificate for record at Ena substation t
End termination /pole mountings of different sizes voltage grade cable with supply installation of chemical earth pits at 4/5/6 and 7/8 incline substation colonies transformers pints etc. of Dhori (k) colliery Dhori Area.
Installation of 04 nos. of 11kV, 1250A, VCB, Meditron make with provision of incoming and outgoing connectors earth leakage relay with CBCT at 33/11-3.3 kV, 22.5 MVA Old Substation of KDH OCP, NK Area