Loading…
Loading…
899 results • Best match
Calibration of Tensile load testing machine for porcelain and composite insulator as per RDSO?s spec. no. TI/SPC/OHE/INSTEST/0090 (02/2009) with A & C-1 or latest , make ASHIAN ENGINEERS COMPANY INDIA
Custom Bid for Services - Calibration of Master Mass Flow Meters of SERPL at FCRI Palakkad or an ISO-17025 compliant laboratory with NABL accreditation Similar Category Maintenance and Pigging Service for Oil and Gas Pipelines
ISE REAGENT FOR ELECTROLYTE ANALYZER, HDC-LYTE ( 2 packet ), QUALITY CONTROL FOR ELECTROLYTE ANALYZER, HDC-LYTE ( 2 packet ), ISE CLEANING SOLUTION FOR ELECTROLYTE ANALYZER, HDC-LYTE ( 3 packet )
Design, Detailed Engineering, Manufacturing and Supply, Augmentation, TPI, FAT, Transportation, Handling, Installation and Commissioning, SAT of CCTV and PAGA System
Primary injection and calibration testing in 3.3KV, 11KV and 33KV panels in Main sub-station and field sub-station and 33kv grade potential Transformers and current Transformers at Main sub-station of Lingaraj OCP, Lingaraj Area
Supply of Machineries and Equipments
Supply of Machineries and Equipments
Dye Penetrant Kit consisting of Red Dye penetrant, Remover/ Cleaner & developer in the ratio 1:4:4 in a set. Visibility-type-II, Washability-Method-C, Sensitivity-Level-2, as per RDSO's specification No. M&C/NDT/105/2001 of April 2001 or latest. (Each Can capacity 500ml and content 400ml net) Drawing & Specification : As per Annexure C.
Custom Bid for Services - Repair & Calibration of BOSCH Make Fuel Injection Pumps (FIPs) and Injectors for BS6D-140 & BS6D-170 Engines of BEML make applicable to WS-28 KL Water Tanker, BG-825 Motor Grader and BD-355 Dozer Similar Category Repair and Overhauling Service
Customized AMC/CMC for Pre-owned Products - 9070C26A95 Expert services for checking and calibration of MS AGAR make level instruments for the AVU unit of Paradip refinery; M/s AGAR Corporation; Comprehensive Maintenance Contract (CMC); Not Applicable..
Repair and calibration of 7 nos. of Fuel Injection Pumps (FIPs) and Injectors/ Nozzles suitable for BS6D-140/ BSA6D170 engines applicable to BEML make BG-825 Motor grader/ WS-28-2 Water Sprinkler and BD-355/ BE1000 Excavators.
Custom Bid for Services - 9070C25C18 Three Years ARC for Testing and Calibration of Ms GE make Moisture analyzers of Paradip Refinery and Petrochemical units by Ms Axis Solutions Private Limited on Proprietary item basis Similar Category Support Services
Supply of 5KV Digital insulation tester with digital and analog display five test range 250 volt, 500 volt, 1000 volt, 2500 volt, 5000 volt. Insulation test up to 10 T hm. The equipment to be supplied with calibration certificate.
Supply, installation, commissioning, calibration & testing Alpha Floor contamination monitor
Drone Charging Station, Drone Mini, Calibration Training Net Outdoor
Set of Go-NO GO Thread ring gauge along with calibration certificate traceable to NABL/NPL. Size- M20 x 2.5 MM - 6g, One set consists of two gauges, One thread ring gauge Go and other No Go (1+1=01 SE
Supply of Digital Insulation Tester including all accessories with auto range of 0- 100V- 500V DC or higher with resolution of 0.001M Ohms. Sanwa MG 102 or similar. This also includes the calibration certificate valid minimum for 1 year from NABL accredited labs.
Custom Bid for Services - Repair Calibration of BOSCH Make Fuel Injection Pumps FIPs and Injectors for BS6D140 BS6D170 Engines of BEML make applicable to WS28 KL Water Tanker BG825 Motor Grader BD355 Dozer BE1000 HYD SHOVEL Similar Category Repair and Overhauling Service
Mass Flow Meter JSG, Spare Flow Transmitter JSG, Calibration charges JSG, Stamping charges JSG, Supervision Charges JSG, Mass Flow Meter KHUNTI, Spare Flow Transmitter KHUNTI, Calibration charges KHUNTI, Stamping charges KHUNTI, Supervision Charges ... KORBA, Calibration charges ...
Custom Bid for Services - ANNUAL MAINTENANCE CONTRACT FOR PERIODIC MAINTENANCE AND CALIBRATION OF MICROHARDNES TESTER TYPE VICKERS HARDNESS TESTER MODEL TUKON 1102 SL NO 110200285 MAKE WILSON FOR A PERIOD OF 03YEARS IN SUKHOI ENGINE DIVISION Similar Category Customized AMC/CMC for Pre-owned Products
Custom Bid for Services - Inspection, Testing and Calibration of SRV and PAV/TSV of LPG Marketing Terminal Paradip Odisha under Rule18 of SMPV (U) Rules, 2016 Similar Category Calibration Services
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Annual Overhauling Service for SADC Positioners servicing and calibration in Unit 4; : Annual Overhauling Service for SADC Positioners servicing and calibration; Service..
Custom Bid for Services - DEGASSING OF BULLET, Custom Bid for Services - DEBOXING OF BULLETS TANK, DISCONNECTION, Custom Bid for Services - SCAFFOLDING FOR PHERE, 1200 MT, Custom Bid for Services - POWER AND LIGHTING ARRANGEMENT, Custom Bid for ... BULLET, NDT , ... WET CALIBRATION OF ... - THIRD PARTY INSPECTION SERVICE ...
Loading/ unloading, Painting, adjusting, & testing accuracy of 20kg & 10 kg CI test weights, issue of verification certificate by State Legal Metrology Department, Odisha as per Weights Measure Act & Rule including providing labour for calibration and stamping of test rake no. 01 for In- motion weigh bridge at Khurda Road".
Cloth Polyester and Viscose Dope Dyed- Uniform Cloth Average Turn Over of Last 3 Years 3000 Lakh (s) Experience with Gov. Required 3 Year (s) Cloth Polyester And Viscose Dope Dyed- Uniform Cloth ( 1765029 ) Technical Specifications Specification ... of Quality Assurance , ...
ITEM 1 SIZE 360 MM X 600 MM 25 MM THICK GRATINGS 375 NOS AS PER DRAWING AS PER SOQR PAGE NO 24, ITEM 2 25 MM THICK GRATINGS AS PER DRAWING AS PER SOQR PAGE NO 24, ITEM 3 SIZE 230 MM X 750 MM 25 MM THICK GRATINGS 3050 NOS AS PER DRAWING AS PER SOQR ... 5 THIRD PARTY INSPECTION CHARGES ...
WHEEL PROFILE GAUGE FOR B.G LOCO DRG.NO.SKDL 3592 ALT-6 OR LATEST (FOR MEASUREMENT OF FLANGE WEAR, ROOT WEAR,TREAD WEAR.TYRE THICKNESS,WHEEL DIAMETER AND FLAT SPOT MEASURING GAUGE), MAKE : JYOTI ENTERPRISES/PARAGON/GANAPATHY MODEL NO: TWG-1 OR ... WITH CALIBRATION CERTIFICATE ...
Supply, installation and commissioning of the Spares and calibration with repairing of Particle Size Analyzer
Calibration Gas (Q3) MSE Exemption for Years Of Experience and Turnover Yes | Complete Startup Exemption for Years Of Experience and Turnover Yes | Complete Document required from seller OEM Authorization Certificate, Additional Doc 1 (Requested in ... category Calibration Gas ...
DIGITAL HEIGHT GAUGE(SINGLE COLUMN) Range: 0-600 mm, Least Count: 0.01mm With NABL Calibration (Q3)
Set of MPT kit consisting of (1) pre mixed black magnetic particle as per RDSO spec. no RDSO/M&C/NDT/109 (Rev-2) OCT-2020 (Wet method) in oil media in 500 ml dispenser operating aerosol/ container (Net content 400 ml/280 gm) (2) White contrast paint as per BS- 5044-1973 in 500 ml dispenser operating aerosol container (Net content-400 ml/280 gm) used with visible magnetic particle for wet method inspection in ratio:-1 (Black): 2 (White).
Colourimeter or Benchtop Spectrophotometer, Calibration board, Sample holder, Measuring apertures, Power adapter, USB cable, Standard accessories, Other accessories
Micro processor based Ultrasonic thickness gauge (with LCD type display), Model no.Edison-1 of M/s Modsonic make or its equivalent in Makes: EECI/ Mitech/ Acorn as per Technical Specification details, Probes & Optional accessories mentioned as per ... Note: Calibration test ...
Supply of Calibration Oil for spectrometer 01 Set. (i) Multi-element standard S-21:00 PPM Qty. 200 gm, (ii) Multi-element standard S-21:50 PPM Qty. 200 gm, (iii) Multi- element standard S-21:100 PPM Qty. 200 gm, (iv) Multi-element standard S-21:300 PPM Qty. 100 gm. Matrix- Base oil 75 CST,
Supply of Digital insulation tester 2.5Kv (Megger) with AC voltage, IR Test Voltage 500V/1000V/2500V, IR Range 0.1 M Ohms to 20 Giga Ohms, 5 digit Large LCD display, single push button operation, data hold function, Test button, inbuilt protection ... and Calibration Certificate.
Manufacturing and supply of Inspection Gauge(including wooden case for gauge) as per RDSO drawing No. T-10311 for In-Sleeper measurement of Turnout switches along with testing and calibration by any government approved lab or by any NABL accredited labs. The gauges are to be manufactured as per specifications mentioned in RDSO drg. No. T-10311.
Manufacturing and supply of Inspection Gauge(including wooden case for gauge) as per RDSO drawing No. T-10311 for In-Sleeper measurement of Turnout switches along with testing and calibration by any government approved lab or by any NABL accredited labs. The gauges are to be manufactured as per specifications mentioned in RDSO drg. No. T-10311.
Facility Management Services - LumpSum Based - ARC CHARBATIA; Structural stability analysis, NDT & structural strengthening of RCC KV (Primary and Secondary) at ARC Charbatia under GE (I) (CG) Bhubaneswar; Consumables to be provided by service provid..
Custom Bid for Services - 200150779, CONTRACT FOR NDT, SCAFFOLDING, INSULATION PAD REMOVAL/INSTALL OF TG AREA PIPING FOR U1 AND U2 DURING OVERHAULING AT NTPC DARLIPALI Similar Category Operation and Maintenance Power House/Power Plant
DIGITAL VERNIER CALIPER With Range of 0 to 150 mm, least count of 0.001 mm, Resolution : 0.0005 in 0.01 mm, Power supply : Button type silver oxide battery, Battery: SR44.938882. Make: Mitutoyo, Precision, Insize, banker, Stanley, Kristeel. supplied ... necessary calibration certificate ...
Customized AMC/CMC for Pre-owned Products - VIDAS; Biomerieux; Annual Maintenance Contract (AMC); Six- Monthly; No
Custom Bid for Services - STACK, AA Qly/FUGITIVE EMISSION MONITORIN & CALIBRATION OF INSTN Similar Category Repair, Maintenance and Installation of Plant Systems/Equipments
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Bid to RA enabled No Type of Bid Single Packet Bid ... Empanelled Inspection Agency /Authority ...
Set of MPT kit consisting of three items :- Item No. (1) Black magnetic ink as per RDSO spec. no RDSO/M&C/NDT/109 (Rev- 2 ) OCT-2020 (Wet method ) in oil media in 420 ml dispenser operating aerosol /container (Net content 400 ml/280 gm)- Qty - 100 Nos. Item No. (2) White contrast paint as per BS- 5044-1973 in 420 ml dispenser operating aerosol container (Net content -400 ml/280 gm ) used with visible magnetic particle for wet method inspection, Qty - 200 Nos. Item No. (3) Cleaner in 420 ml. Aerosol container (Net content -400 ml/280 gm ), Qty - 100 Nos.
Sensor Chlorine Detector Chennai Chloro, Display cum Controller Chlorine Detector, Calibration Sample Gas Chlorine 2 PPM, Chlorine Detector sensor Chennai Chloro, Chlorine Detector display cum controller
Custom Bid for Services - 9070C26A31 Service Contract for Checking, Maintenance and Calibration of Gas Detectors installed at Paradip Refinery and Petrochemical Complex Similar Category Support Services
Homogenizer
Stationary Valve Regulated Lead Acid Batteries (V2) as per IS 15549 (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Experience Criteria, Past Performance, Bidder Turnover, Certificate (Requested in ATC), OEM Authorization Certificate, OEM Annual Turnover, Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 3 Bid Number : GEM/2025/B/6940103 Dated : 27-11-2025 Bid Document 1/6, -- Number of days for which Bid would be auto -- extended 7 Number of Auto Extension count 1 Past Performance 50 % Bid to RA enabled No Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Bid Details EMD Detail Required No ePBG Detail Required No
NITROGEN EVAPORATOR
VIDAS SLMKIT, VIDAS LMO2, API 20 E