Loading…
Loading…
518 results • Best match
MATER PIECE FOR AXLE SNAP GAUGE FOR DIA 130.00 MM, DRG NO XG044101 ALT "NIL" CALIBRATION CERTFICATE IS REQUIRED WITH TRACEABLE TO NABL.
Customized AMC/CMC for Pre-owned Products - Calibration of moisture Meter and printers; Indosaw and Duvcon; Annual Maintenance Contract (AMC); When Needed; Yes
Hexagonal Head Bolt for Motor mounting 5/8" x 18TPI x 2-1/2" length to DLW part No. 19016025 with suitable Hexagonal head lock nut 5/8" x 18 TPI to DLW part No. 19355208. Note: Item to be supplied as
HIGH TENSILE, HEXAGONAL HEAD CAP SCREW 1 INCHE - 8 TPI(UNC) x 3-1/2 INCHES LONG TO SRLY DRG NO. SR/D/BT-116/B2 ALT NO.'2' WITH ELASTIC STOP NUT & WASHER. MATERIAL SPECN: (1) FOR BOLT-IS 1367 PART 3,
Lathe Machine, Geared Shaping Machine, Power Hacksaw Machine, Heavy Duty Drilling Machine, Portable Hand Drilling Machine, Bench Grinders, Angle Grinders 7inch, Angle Grinders 4inch, Welding Transformer, Set of Mandatory Spares, Set of Erection and ... Spares, Third Party Inspection Charges, ...
Customized AMC/CMC for Pre-owned Products - AMC and Calibration Contract for DMMs; Keysight; Comprehensive Maintenance Contract (CMC); As Per Scope of Work; No
MAINT TO CERTAIN TRANSFORMER, PROTECTION SYSTEM, HT OVER HEAD AND CABLE NETWORK INCLUDING CALIBRATION OF RELAYS UNDER GE (S) MAMUN AT MAMUN MIL STN
Go Gauges for Checking of Inner Labyrinth (DE) to Drg. no.G-0564 Note: Firm has to submit calibration certificate from any NABL approved Lab
Supply of spares, fitment and calibration of main bearing ratchet Avanti -01 and power pack machine of HYTORC, details as per Annexure-A Make: HYTORC
boot high ankle leather dvs Boot High Ankle Leather Dvs ( 310 ) Technical Specifications Specification Specification Name Values Allowed Values SPECIFICATION Governing Specification Confirming to IND/TC/3844(a) standards (Specification issued by ... of Quality Assurance , ...
Set of 02 Items Consisting of (1) Bolt Hex Head of Size 5/8" X 11 TPI UNC X 1-1/2 Inch Long to Part No: 271558 and DLW Part No.19016190,Qty 1344 Nos (2) Washer Special - Damper to EMD part No.9532904
BOLT HEX HEAD 3/4 Inch X 16 TPI X 7-1/2 Inch for coupling disc mounting of Grade 8 to EMD PT No 9430309 and DLW PT No 19019130 with suitable Ny lock Nut of the make TVS and BIMCO. Firms Offer: --do--
Hex. Head Bolt 5/8 inch -11 TPI (UNC) x3-1/2 inch long thread length 1-1/2 inch to DLW Drg No.TPE-13-0044 (SL. NO.60) ALT. No. 't' or latest and to DLW Part No.15090231. Material Specn:(1) IS:1367 (PT
Calibration Services - Fluid flow; Mass Flow Meter; FCRI Palakkad or any other equivalently recognized body of fluid control and measurement by Government of India; Buyer premises (onsite)
REPAIR MAINT REPLACEMENT OF HT NETWORK INCL HT VCBs TRANSFORMERS DEHYDRATION OF TRANSFORMER OIL INCLUDING CALIBRATION OTHER CONNECTED HT EQUIPMENT AND CERTAIN EM WORKS UNDER AGE I SURANUSSI
Horizontal Type Dynamic Balancing Machine with latest Controller based measuring panel, auto calibration facility, auto-cycle with adjustable time, with minimum unbalance mass measure limit 0.1 gm and
1/2" SQUARE DRIVE RATCHET TYPE TORQUE WRENCH CAP-70-340 NM(7-35 KGM), as per : IS:7268-1974 (CALIBRATION CERTIFICATE SHOULD BE PROVIDED BY THE FIRM)
Set of 03 Items consisting of three items as per details below: 1. Bolt Hex head 5/8 inch -11 TPI UNC x 2-1/2 to EMD pt No.271723 and DLW Pt No.19010175, Qty/set-01 No. 2. Nut Hex lock 5/8 inch -11-
SERVICE AND CALIBRATION OF SURVEY EQIPMENT NO 01, SERVICE AND CALIBRATION OF SURVEY EQIPMENT NO 02, SERVICE AND CALIBRATION OF SURVEY EQIPMENT NO 03, SERVICE AND CALIBRATION OF SURVEY EQIPMENT NO 04, SERVICE AND CALIBRATION OF SURVEY EQIPMENT NO 05, ... AND CALIBRATION OF ...
Customized AMC/CMC for Pre-owned Products - CAMC and Calibration Contract for DMMS whose details attached in Equipment details; Keysight Digital multi metres; Comprehensive Maintenance Contract (CMC); quarterly; Yes
Suit to "MITUTOYO" Digimatic (digital) vernier caliper, ABSOLUTE Coolant proof, IP- 67, Model No. CD-P12" S, size -300mm, Material stainless steel, Battery - SR44X1 . Note:- Material to be supplied along with calibration certificate and warranty ... with calibration certificate ...
Digital Vernier Calliper, Range: 0-300mm, Resolution: 0.01mm, Make: Mitutoyo, Baker, Tesa, Insize or Similar. Note: Calibration Certificate from accredited/ NABL valid for 1 year to be provided with e
Custom Bid for Services - Sply of HCDs POINT TYPE with one calibration Kit, Custom Bid for Services - Sply of 2 pair Cu Cable armoured 1 point5sqmmFRLS, Custom Bid for Services - Sply of FLP Hooter cum flasher, Custom Bid for Services - Sply of Heat ... with Calibration Kit, ... with Calibration Kit, ...
Suit to "Torque master" ALLEN HEAD type "TORQUE WRENCH" size 3/8", rang 90 LBF, Material Stainless steel . Make- Torque /Master/MAC master/ Britool. Note:- Material to be supplied along with calibration certificate and warranty certificate by OEM. ... with calibration certificate ...
ABSOLUTE Digimatic Depth Gauge Series 571, Range 0-300 mm, Resolution 0.01mm, of Mitutoye code 571-203-20 or equivalent Note: Firm has to submit calibration certificate from any NABL approved Lab
SET OF MASTER CYLINDRICAL MANDREL (06 TYPE) FOR ZERO SETTING OF SNAP GAUGES AS PER DRG NO. G-0573 FOR 6FRA 6068 TRACTION MOTOR ALONG WITH CALIBRATION CERTIFICATE FROM NABL-APPROVED LAB.
Customized AMC/CMC for Pre-owned Products - ANNUAL MAINTENANCE CONTRACT FOR CALIBRATION REPAIR OF DIGITAL MOISTURE METERS WITH THERMAL PRINTERS; DUVCON ORCA INDOSAW; Annual Maintenance Contract (AMC); FOUR MONTHLY OR WHEN REQUIRED; Yes
Custom Bid for Services - Annual Maintenance Contract for 01 no 60MT Pitless Electronic Weighbridge installed at DCTPhillaur Punjab including Annual Stamping and Calibration charges for Weighbridge and Standard Weights from Weights Measurement Depar..
Digital pressure gauge, Range: 0-35 Bar, Resolution: 0.001 kg /cm 2 , Accuracy +/- 1 % FS. Connection 1/2"(BSP), LCD display of five full digits for showing various pressure units with calibration cer
SET OF FLUORECENT DYE PENETRANT KIT FOR ZYGLO TESTING TO RDSO SPEC. NO. M&C/NDT/105/2001. SET CONSISTING OF 02 ITEMS. (1) WATER SOLUBLE FLUOROSCENT DYE PENETRANT TYPE 1, METHOD-A, SENSITIVITY LEVEL-3 (20 MICRON) - 20 LITRES CAPACITY PACK/CONTAINER. (2) DYE DEVELOPER POWDER 1.0 KG AIR TIGHT PACK/CONTAINER.
DYE PENETRANT TEST KIT CONTAINING FOLLOWING : 1. RED DYE PENETRANT = 1X400 ml can 2.DEVELOPER = 2X400ml can 3.PENETRANT REMOVAL = 3X400ml can. IS:12889/1989 & IS:3658/1981 confirming to RDSO specification No. M&C/NDT/105/2001. i.e.(PENETRANT:DEVELOPER:REMOVER: 1:2:3) Can size:- 500 ml, Can vol. 400 ml net content.
Custom Bid for Services - Annual Maintenance Contract for 01 no 60MT Pitless Electronic Weighbridge installed at ICDDDL Ludhiana including Annual Stamping and Calibration charges for Weighbridge and Standard Weights from Weights and Measurement Depar..
Work includes carrying out calibration of furnace i.e. conducting temperature uniformity survey to qualify the electric furnace which is used for heat treatment process like stress relieving, normalizing, annealing, tempering etc. as per NABL
Repair Replacement Maintenance of external HT Network HT VCB Calibration of repair maint of transformer Dehydration of transformer Oil including other HT equipment and allied Works at Mil Stn Suranussi under AGE I Suranussi
One set (5 types) of Master Cylindrical Mandrel for Zero setting of snap Gauges as per Drg. No. G-0573 for Hitachi Traction Motor. Note: Firm has to submit calibration certificate from any NAB
P1, P2, P3, P4, P5, P6, P7, P8, P9, P10, P11, P12, P13, P14, P15, P16, P17, P18, P19, P20, P21, P22, P23, P24, P25, P26, P27, P28, P29, P30, P31, P32, P33, P34, P35, P36, P37, P38, P39, P40, P41, P42, P43, P44, P45, P46, P47, P48, P49, P50, P51, P52, P53, P54, P55, P56, P57, P58, P59, P60, P61, P62, P63, P64, P65, P66, P67, P68, P69, P70, P71, P72, P73, P74, P75, P76, P77, P78, P79, P80, P81, P82
Providing Fixing Repair and Calibration of OCEMS and Repair Replacement of CCTVs Including Wiring DVR Anteenas and all other works contingent thereto at 95 MLD Sewage Treatment Plant South Zone and North Zone at Amritsar
Customized AMC/CMC for Pre-owned Products - AMC FOR One no 60MT PITLESS ELECTRONIC WEIGHBRIDGE INSTALLED AT ICD DDL LUDHIANA PUNJAB INCLUDING ANNUAL STAMPING CALIBRATION CHARGES for weighbridge and standard weights FROM WEIGHTS MEASURES DEPARTMENT ..
10 Inches Master Pressure Test Gauge for Gauge Calibration. Range : 0-16 kg/Cm2, Least count: 0.05 kg/cm2 Accuracy: +/ 0.25% FSD, Connection: 3/8 inch BSP (M) bottom. Make/Brand: Midlands/Topgrip or s
Custom Bid for Services - Annual Maintenance Contract for 01 no 100 MT Pit Type Fully Electronic Lorry Weighbridge installed at RCTDappar Punjab including Annual Stamping and Calibration charges for Weighbridge and Standard Weights from Weights Meas..
REPAIR/REPLACEMENT/MAINTENANCE OF DISTRIBUTION TRANSFORMERS EARTHING VCB RELAY HT CABLES CALIBRATION TRANSFORMER DEHYDRATION ALLIED WORKS AT 66 KV GRID STATION AND ALL CONNECTED ITEMS OF EXTERNAL ELECTRIC SUPPLY AT OLD AMRITSAR CANTT UNDER GE AMRITSA
3/4" SQ DRIVE RATCHET TYPE TORQUE WRENCH CAP- 14-70 Kgf.m (135-675NM), as per Drawing: IS: 6789-2003 OR LATEST WITH CALIBRATION CERTIFICATE SHOULD BE PROVIDED BY THE FIRM, WITH DETAILS OF MASTER EQUI
PARTICLE COUNTER
PARTICLE COUNTER
1/2" SQ DRIVE RATCHET TYPE TORQUE WRENCH CAP-7-35 Kgf.m (70-340 NM), as per Drawing: IS: 6789-2003 OR LATEST WITH CALIBRATION CERTIFICATE SHOULD BE PROVIDED BY THE FIRM, WITH DETAILS OF MASTER EQUIPM
1/2" SQ DRIVE RATCHET TYPE TORQUE WRENCH CAP-7-35 Kgf.m (70-340 NM), as per Drawing: IS: 6789-2003 OR LATEST WITH CALIBRATION CERTIFICATE SHOULD BE PROVIDED BY THE FIRM, WITH DETAILS OF MASTER EQUIPM
CONTRACT FOR SUPPLY INSTALLATION AND CALIBRATION OF GAS CHROMATOGRAPH
Repair, maintenance, calibration of Lab testing machines at HQ CEBZ
Cell pack Pack of 20 ltr, Stromatolyser wh bottle of 500 ml pkt of 3 bottle, Cell clean bottle of 50 ml, Quality control of Sysmex XP 300 bottle of 3 set, Printer paper roll Sysmex
Custom Bid for Services - Custom Bid for services AMC for 1 100 MT Pitless type fully Electronic Weighbridge installed at MMLP PLIL including annual stamping calibration charges for weighbridge and standard weights from Weights and Measures Departmen.. Similar Category Customized AMC/CMC for Pre-owned Products