Loading…
Loading…
2,823 results • Best match
Custom Bid for Services - Outsourcing at HAL-Korwa premises of Repair/Overhaul/Production/FT of Western and Russian LRUs Similar Category Calibration Services
Custom Bid for Services - Contract for Calibration of Test point CTs VTs Std CTs CT Analyzer of Transformer Testing Laboratory at BHEL Jhansi
Custom Bid for Services - Checking Overhauling & Re- Calibration Work(AMC) Similar Category Customized AMC/CMC for Pre-owned Products Repair and Overhauling Service
Custom Bid for Services - Service PR for Calibration of OnlineOffline Energy Meters of AuGPS Similar Category Operation and Maintenance Power House/Power Plant
Reagents One, Reagents Two, Reagents Three, Reagents Probe Cleaner, Hematology Quality Control, Hematology Sc Cal Plus Calibrator
REPAIR/MAINT TO E/M INSTALLATION AND ELECTRICAL ENERGY AUDIT OF ASSETS HELD ON CHARGE OF GE (AF) SARSAWA AT AF STN SARSAWA UNDER GE(AF) SARSAWA
Calibration Services - Refer Scope of Work for Group I; Refer Scope of Work for Group I; NABL Labs; Refer Scope of Work for Group I, Calibration Services - Refer Scope of Work for Group II; Refer Scope of Work for Group II; NABL Labs; Refer Scope of Work for Group II
Non aqueous Developer (Spray type application), Form-D in Aerosol Cans of Capacity 500 ml, Net Content 400 ml, conforming to IS:3658/1981, IS:12889/1989 and RDSO Spec No. M&C/NDT/ 105/2001 used in Dye
KIT OF DYE PENETRANT TEST FLOW CHECK IN 400 ML. CANE KIT COMPRISING 3 ITEMS 09 NOS.(1)PENETRANT -01 NO. CANE (2) CLEANER 04 NOS. CANE (3) DEVELOPER-04 NOS. CANE RDSO SPECIFICATION NO.M/C/NDT/105/2001
KIT OF DYE RENETRANT TEST FLOW CHECK IN 400 ML. CANE KIT COMPRISING 3 ITEMS 09 NOS.(1)PENETRANT -01 NO. CANE (2) CLEANER 04 NOS. CANE (3) DEVELOPER-04 NOS. CANE RDSO SPECIFICATION NO.M/C/NDT/105/2001
Set of chemicals to detect surface crack in metals. Type II and method C as per RDSO Spec.No: M&C/NDT/105/2001. One set consists of 2 items as given below (1) penetrant - 01 No/set, (2) developer -
Testing and calibration of M/s Secure Meters ltd. Non ABT type energy meters installed at ATP Anpara , Sonebhadra as per scope of work
Calibration Services - REPAIR OF CM20 PARTICLE COUNTER TESTER; REPAIR OF CM20 PARTICLE COUNTER TESTER; Any other Government Approved Labs/Service Provider; Buyer premises (onsite)
Testing and calibration of protective relays along with the testing of CTs, PTs, and transformers installed at Coal and OB substation of Khadia Project
REPAIR/ MAINT OF HT BREAKERS HT APFC PANELS, CALIBRATION OF VCBs AND HT ELECTRIC LINE ITS CONNECTED WORK AT CHHEOKI UNDER GE (W) PRAYAGRAJ.
PERIODICAL MAINTENANCE OF DISTRIBUTION TRANSFORMER NETWORK CALIBRATION OF SWITCHGEARS AND PROTECTION SYSTEM AND ALLIED WORKS AT CANTT AREA UNDER AOR OF GE I KANPUR
REPAIR/MAINT TO SERVICING/CALIBRATION OF 11 KV VCBs AND REPAIR/MAINT OF HT CABLE NETWORK AT VARIOUS LOCATION UNDER GE E/M LUCKNOW
Thread plug gauge GO & NO GO Size-M 16 x 1.5 mm pitch with calibration certificate (NABL CERTIFIED LAB),Make-HIP/BAKER or similar
Digital vernier caliper range 0-450 mm, material stainless still. Calibration certificate approved by NABL or other government approved agency MAKE : METOTUYO OR SIMILAR
Hand operated (Metal body) Insulation tester (Megger) 2500 Volts with resitance range 0-10000 Mega ohm, measurement accuracy (%) :2.0 or better alongwith calibration certificate.
Collar type LED pressure gauge size- 6 inch, capacity 0-10 kg/cm square with calibration certificate (NABL Certified lab) Make - Altop or similar.
Collar type LED pressure gauge size- 4 inch, capacity 0-7 kg/cm squaire with calibration certificate (NABL Certified lab) Make - Altop or similar.
Collar type LED pressure gauge size- 6 inch, capacity 0-7 kg/cm square with calibration certificate (NABL Certified lab) Make Altop or similar
Collar type LED pressure gauge size- 4 inch, capacity 0-10 kg/cm square with calibration certificate (NABL Certified lab) Make - Altop or similar
GO & NO GO Thread ring gauge Size-M 16 x 1.5 mm pitch with calibration certificate (NABL CERTIFIED LAB),Make-HIP/BAKER or similar
Engagement of Consultant for obtaining NABL Accreditation of Hi-tech Meter Test Lab MVVNL Gomtinagar, Lucknow alongwith Calibration of equipments Installed in the lab
Custom Bid for Services - JOB CONTRACT FOR CALIBRATION OF ELECTRICAL LAB EQUIPMENT AT NTPC Unchahar Similar Category Operation and Maintenance Power House/Power Plant
Custom Bid for Services - 200133514 CALIBRATION OF COMMERCIAL SPECIAL ENERGY METERS INSTALLED AT NTPC SINGRAULI Similar Category Operation and Maintenance Power House/Power Plant
Calibration Services - Volumetric Flask One Mark Burette Graduted pipette Glass Termometer Weight Box; For analysis of samples; NABL Labs, Any other Government Approved Labs/Service Provider, CIPET Lucknow; Buyer premises (onsite)
Replacement of plate type air-pre heater (Tag No. 302-E-56B) including enabling jobs, rigging, welding, NDT, assistance in leak test and carrying out allied civil/ structural and mechanical works on Lumpsum basis during HGU-2 shutdown at MR
Custom Bid for Services - 200141864 NDT Thickness survey and Material Mixup checking of TG area Piping system during Overhauling of TG and Aux NTPC Dadri Stage-I 4x210MW and II 2x500MW Similar Category Operation and Maintenance Power House/Power Plant
Custom Bid for Services - 200141543 NDT TEST MPI Hardness Fibroscopy DPT UT oxide scale measurement Exfoliation of SS joints bends checking testing in Boilers at NTPC Unchahar 5x210 and 1x500 MW Similar Category Operation and Maintenance Power House/Power Plant
Repair and Overhauling Service - Wheeled Skid Steer Loader (V2) as per IS/ISO 7131 (Latest); REPAIR AND CALIBRATION OF CRANE 10 TON TIL; Yes; Buyer Premises, Repair and Overhauling Service - Wheeled Skid Steer Loader (V2) as per IS/ISO 7131 (Latest); ... AND CALIBRATION OF ...
boot high ankle leather dvs Boot High Ankle Leather Dvs ( 240 ) Technical Specifications Specification Specification Name Values Allowed Values SPECIFICATION Governing Specification Confirming to IND/TC/3844(a) standards (Specification issued by ... of Quality Assurance , ...
Selection of a Consultant for Carrying out Road Safety Audit at DPR Stage of Proposed Ganga Expressway Project in the State of Uttar Pradesh
WORK OF REPAIRING / REPLACEMENT OF COOLING FAN , CONTROL SWITCHES AND DOOR RIBBON IN MARSHALLING BOX , MCB , OLR AND CONTACTOR OF DM BOX AND ANNUNCIATION ALARM , OTI , WTI , TPI AT RTCC PANEL OF 40 MVA TRANSFORMER-I AND HEIGHT RAISING OF 30 KV LA AT
Bolt and Washer kit for HHP Locomotive. 1) Bolt Hex Head, Size: 1" - 8 TPI x 2-1/2" Long to EMD Part No. 271549, Qnty-1 No., 2) Washer Lock, Size: 1" to EMD Part No. 8137697, Qnty-01 No. and 3) Camsha
Custom Bid for Services - Lumpsum amount inclusive of all Charges and GST presently at 18 percent for service contract for Testing and Calibration of Protective Relays, Meters and Transducers installed in Electrical Panels for 24 months at GAIL Pata ... Category Calibration Services ...
For Annual Maintenance, Breakdown Maintenance, Calibration of Equipments, NABL Accreditation and Efficient Operation of Automatic Meter Testing Lab,Under Paschimanchal Vidyut Vitran Nigam Limited, Meerut.
Custom Bid for Services - Muffle furnace Hot air oven Pour point Digital temp indicator of able flash point Top Loading Balance Similar Category Calibration Services
REPAIR/ MAINT OF HT BREAKERS HT APFC PANELS, CALIBRATION OF VCBs AND HT ELECTRIC LINE ITS CONNECTED WORK OF ARMY AREA AT NEW CANTT PRAYAGRAJ.
Testing and calibration of relays installed in 33 6.6 6.0KV panels, field switches etc. and testing of oil of various power transformers at Bina project
Testing and calibration of relays installed in panels of 4 way panel 6.6 KV, 33 KV panel, field switch unit and transformers at Krishnashila Project.
Testing Calibration and Functionality check of Numerical relays of Machine No. 1 2and 3 and Jhansi 1st and Roda Feeder at Matatila Hydro Power Plant
Dial Tension Gauge with Center Zero. 5-50 Grams, Least Count -01 Gram with Calibration Certificate along with Traceability. Make- Blue Steel, Milhard, Mitutoyo, Kontaktor.
DIGITAL SNAP GAUGE RANG 125-150MM WITH DIGITAL INDICATER, MASTER DISC DIA 130MM & 140MM , LEAST COUNT 0.001MM WITH CALIBRATION CERTIFICATE MAKE- MITUTOYO/ BAKER OR SIMILAR
SUPPLY, INSTALLATION, TESTING AND COMISSIONING OF HORIZONTAL TYPE DYNAMIC BALANCING MACHINE WITH LATEST CONTROLLER BASED MEASURING PANEL, AUTO CALIBRATION FACILITY, AUTO CYCLE WITH ADJUSTABLE TIME
Autoclave, Compression Testing Machine, Controlled Water bath, Dial gauge, Digital Indicator, Digital Micrometer, Digital Thermo Hygrometer, Digital Vernier caliper, Environmental Chamber, Electronic Weighing Balance, Electronic Balance, Feeler Gauge, Glass Thermometer, Humidity Chamber, Le-Chatelier Flask, Le- Chatelier Water Bath, Micrometer, Metal Scale, Hot Air Oven, Dial Pressure gauge, Proving ring, Reference Length Bar, Refrigerated Water bath, Tile Abrasion testing machine, Universal Testing, Vernier calliper
Customized AMC/CMC for Pre-owned Products - 9050C26A57 Expert services of M/s SAMSON CONTROLS PRIVATE LIMITED for Calibration, troubleshooting & maintenance services for control valves installed in New units Mathura Refinery; SAMSON CONTROLS PRIVATE ..
Custom Bid for Services - Lumpsum amount inclusive of all Charges and GST presently at 18 percent for service of ECT and Helium Leak Testing Services for Inspection of Plant equipment at GAIL Pata