Loading…
Loading…
2,444 results • Best match
Ranaghat Aranghata New Road from Ch 2 Km to Ch 2.80 Km and Ch 3.30 Km to Ch 4 Km emergent patch repairing and maintenance work under Quality Control Sub Division No.I of Nadia Highway Division No.II PW Roads Dte, in the District of Nadia
Restoration of water logged zone at Ranaghat Aranghata New Road from Ch 1.685 Km to Ch 1.800 Km under Quality Control Sub Division No I of Nadia Highway Division No II PW Roads Dte in the District of Nadia during the Year 25-26
Temporary restoration work in patches due to excessive Rainfall on Bishnupur Aishmali Road from Ch 1.50 Km to Ch 4.00 Km under Quality Control Sub Division No I of Nadia Highway Division NoII PWRoads Dte in the District of Nadia during the Year 25-26
Please refer tender documents.
Set of material traction alternator foun [Set of material traction alternator foundation bolt with washer, consist of: 1. Bolt Hex Head,Size: 1-1/2" - 6 TPI x 4- 1/4" Long to EMD Part No. 272572, Qty/set-1 No, 2. Washer Special,Size: 1-35/64" ID x 2-5/8" OD, 45 degree chamfer on both sides to EMD part No. 9334651, Qty/set -01 No. Material spec: 1. GM 280 - M - STEEL. 2. SAE 4140H STEEL , Temper to Rockwell ?C? 32-36. ]
Conducting Structural Health Assessment monitoring work for the identification of damaged of existing structure by Non Destructive methods NDT and by sensors with expert Reports and commands at Sunray Housing Project.
Custom Bid for Services - Contract for maintenance, servicing and calibration of Automatic Bomb Calorimeter (Model: IP-1, Make: Advance Research Instruments Company) at Chemical Laboratory, MTPS, DVC for a period of 2 (Two) years Similar Category ... Services Calibration Services
Repairing, servicing and calibration of Fuel injection pumps with injectors (P4 and S4) at Road Roller Deptt.
SUPPLY INSTALLATION TESTING AND COMMISSIONING OF STRAIN GAUGE CALIBRATION SYSTEM WITH TENSILE COMPRESSIVE AND FLEXURAL LOADING FACILITY
Complete inspection internal cleaning, Testing and calibration, Servicing and calibaration of relectometer, Servicing of digi point receiver
Automated HPLC for Biostimulants
K V meter Self illuminated flush type moving coil AC Voltmeter with inbuilt rectifier with metal clamp and shock proof rubber gasket to range 0-170 volts to be graph 0- 30KV with suitable calibration as 140 V Showing 25 KV. Size:- 96 x 96 mm Accuracy + 1.5% to IS 1248/1968 or latest
Breath Alcohol Analyzer with inbuilt internal thermal printer with all accessories, with 03 years warranty and 03 years free calibration. [Confirming the RDSO Specification no. RDSO/2015/EL/SPEC/0119 (Rev `2'), Dated 15.03.2018.]. OEM authorized warranty certificate to be submitted at the time of material supply. Make:- ADDSOFT/ TAYALTECH /FIT 333 or similar.
K V meter Self illuminated flush type moving coil AC Voltmeter with inbuilt rectifier with metal clamp and shock proof rubber gasket to range 0-170 volts to be graph 0- 30KV with suitable calibration as 140 V Showing 25 KV. Size:- 96 x 96 mm Accuracy + 1.5% to IS 1248/1968 or latest.
K V meter Self illuminated flush type moving coil AC Voltmeter with inbuilt rectifier with metal clamp and shock proof rubber gasket to range 0-170 volts to be graph 0- 30KV with suitable calibration as 140 V Showing 25 KV. Size:- 96 x 96 mm Accuracy + 1.5% to IS 1248/1968 or latest.
Set of Digital dial gauge with magnetic base includes following items: 1) Digital dial gauge similar to model DGI/2 (high accuracy) specification Range: 0-12.70 mm, accuracy: 0.005mm, Resolution: 0.001 mm. with NABL certified calibration certificate. 2) Magnetic base Model similar to Mitutoyo 7010s-10. Make: Mitutoyo, Baker, Groz, Precise, Krost or similar.
Road signage work of SH-3 Pandav More to Duttapulia More from 5.00 km to 35.00 km and Rumble Strip work on Bishnupur Aishmali and Nokari Aishmali Road of Quality Control Sub-Division No-1 under Nadia Highway Division No-II during the year 2025-2026
Design, Preparation and Approval of drawing from competent authority, Fabrication, Erection, Welding, NDT, PWHT, Hydrostatic and Pneumatic Testing, Blast cleaning, Painting and Final Documentation of various Pressure Vessels of 425 MT and
SUPPLY, INSTALLATION AND CALIBRATION OF 12 VOLT, 100 AH SMF BATTERIES WITH BUYBACK OF SAME NUMBER OF BATTERIES
Repairing of electromegnatic flowmeter with calibration at WTP of Panskura surface water supply scheme under MMD PHE Dte.
SUPPLY, INSTALLATION AND CALIBRATION OF 12 VOLT, 42 AH SMF BATTERIES WITH BUYBACK OF SAME NUMBER OF BATTERIES
Servicing, testing, calibration and commissioning of different types of relays and other auxiliary work at Auckland Sq BPs
1) M10 x 60 HT Stud with both side threaded length 16 mm & 35 mm with 01 No Nut,02 Nos Flat Washer and 01 No Spring Washer. Material Specification Stud is : IS:1367(Pt-III) 1991 PC 8.8 Nut IS 1367 (Pt IV) 1986 PC-8 Plain washer IS: 2016/1964, Spring ... 18 TPI X ...
Manufacturing and supply of Inspection Gauge(including wooden case for gauge) as per RDSO drawing No. T-10311 for In-Sleeper measurement of Turnout switches along with testing and calibration by any government approved lab or by any NABL accredited labs. The gauges are to be manufactured as per specifications mentioned in RDSO drg. No. T-10311.
Manufacturing and supply of Inspection Gauge(including wooden case for gauge) as per RDSO drawing No. T-10311 for In-Sleeper measurement of Turnout switches along with testing and calibration by any government approved lab or by any NABL accredited labs. The gauges are to be manufactured as per specifications mentioned in RDSO drg. No. T-10311.
Thermal Gun High accuracy Industrial digital infrared thermometer, Temp. Range- - 38 to 520 degree C, IP 20 for dust protection, Deviancy-2% or +/- 2 deg, Response time-500 miliseconds, Resolution-0.1, 8:1 distance/10 cm spot from 10 meter, Battery ... powered, Calibration certificate ...
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Ship; L-103: Calibration test of electrical equipments; Buyer
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - 88 ACV SQN; CALIBRATION OF GYRO COMPASS; Service Provider
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - 88 ACV SQN; CALIBRATION OF GYRO COMPASS; Service Provider
Self recording Rain gauge with clock drum, Calibration Certificate, Packing, Thermograph with clock drum, Hair hygrograph with clock drum
Dynamic calibrator for chloride analyser Orion, Sodium Analyser Calibration Kit, Oxygen Scavenger Dynamic calibrator, Chiller Bath for Chloride Monitor
1. White Contrast Paint for Magnetic Particle Inspection (Packing: 500ml can volume. Net content: 400 ml Aerosol can) (Confirming to BS: 5044, BS: 6072, IS: 3703, ISO: 9934), Make/Brand: ORION WCP-61 or similar. 2. Black Magnetic Particle ink for ... RDSO/M&C/ NDT /109/2007 ...
1. White Contrast Paint for Magnetic Particle Inspection (Packing: 500ml can volume. Net content: 400 ml Aerosol can) (Confirming to BS: 5044, BS: 6072, IS: 3703, ISO: 9934), Make/Brand: ORION WCP-61 or similar. 2. Black Magnetic Particle ink for ... RDSO/M&C/ NDT /109/2007 ...
1. White Contrast Paint for Magnetic Particle Inspection (Packing: 500ml can volume. Net content: 400 ml Aerosol can) (Confirming to BS: 5044, BS: 6072, IS: 3703, ISO: 9934), Make/Brand: ORION WCP-61 or similar. 2. Black Magnetic Particle ink for ... RDSO/M&C/ NDT /109/2007 ...
STRUCTURAL HEALTH ASSESSMENT OF Dr B C Roy LECTURE THEATRE BY NDT TESTING AND VISUAL SURVEY REPORT PREPARATION AND BOQ FOR RESTORATION WORK OF Dr B C Roy LECTURE THEATRE NRS MEDICAL COLLEGE and HOSPITAL
Custom Bid for Services - Deployment of Service Engineers for Inspection of Boiler Pressure Parts, Duct & Dampers and NDT Services during Overhauling of Unit#8 at MTPS Similar Category Operation and Maintenance Power House/Power Plant
Testing, Adjusting and calibration of Non automatic 12 (Twelve) nosWeigh Bridges of capacity 60 MT each through competent Government authority
Manufacture, Supply, Installation, Commissioning , Calibration and Prove out of 1 No of 600 kN Universal Testing Machine on Turnkey Basis
RHM24R5015 PIONA Calibration Kit MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Certificate (Requested in ATC), Additional Doc 1 (Requested in ATC), Additional Doc 2 (Requested in ATC), Additional Doc 3 (Requested in ATC), Additional Doc 4 (Requested in ATC), Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 5 Days Inspection Required (By Empanelled Inspection Authority/Agencies pre- registered with GeM) No Evaluation Method Total value wise evaluation Bid Number ( ) : GEM/2024/B/4960969 Dated : 20-05-2024 Bid Document 1/5 EMD Detail Required No ePBG Detail Required No Splitting
DIGITAL DEPTH GAUGE FOR TRACTION MOTOR SPEED SENSOR OF THREE PHASE LOCOMOTIVE AS PER SR.DEE/RS/GZB/DRG NO. 930/MECH/PARTS/2024, ALT-NIL AS PER ATTACHED SPECIFICATION IN ANNEXURE-1. Note:- Valid calibration certificate from NABL/Govt. Approval Laboratory to be supplied along with the material. 2. Good Quality wooden carrying/keeping box to be provided for Item separately
Non contact infrared thermometer for ind [Non contact infrared thermometer for industrial use, Details specification as per attached Annexure. Note: 1.Tender specific data sheet along with brand against the offer product should be provide at the time ... with calibration certificate ...
DIGITAL DEPTH GAUGE FOR TRACTION MOTOR SPEED SENSOR OF THREE PHASE LOCOMOTIVE AS PER SR.DEE/RS/GZB/DRG NO. 930/MECH/PARTS/2024, ALT-NIL AS PER ATTACHED SPECIFICATION IN ANNEXURE-1. Note:- Valid calibration certificate from NABL/Govt. Approval Laboratory to be supplied along with the material. 2. Good Quality wooden carrying/keeping box to be provided for Item separately
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Office Space; reaoer of exhaust funnel deck, servicing of fire extingushers, NDT of mooring cleats, Bollards, lifting points, jacking points and load testingof deck crane onb..
Calibration of 4 nos of Trolley mounted Master Flowmeter skids (ENDRESS HAUSER make) of IOCL Haldia Refinery Terminal from FCRI Pallakad
Manpower Outsourcing Services - Fixed Remuneration - Office Attendant; Multi-tasking Staff; High School
Five Yearly Statutory Testing of 02 nos 150 MT Capacity Propane Mounded Bullets including NDT and Hydrotest and issuance of Complete Inspection report and Certificate as per appilcable Guidelines Rules and standard of PESO and OISD 150
2026- 27 (AMI No. 32.74) Multistix for urine chemistry,%u22659 Parameter i.e- Protien, Glucose, pH, Bilirubin, Nitrite, blood, ketone, Urobilinogen, Sp.gravity. PACK SIZE - 100 STRIPS/ PACK, NOTE- The firm supplying the multistix strips will provide ... for quality control of ...
Five Yearly Statutory Testing of 03 nos 2026 MT Capacity LPG Mounded Bullets including NDT Hydrotest at IndianOil Petronas Pvt Ltd Haldia and issuance of Complete Inspection report and Certificates as per PESO OISD 150 and applicable guidlines
Custom Bid for Services - Deployment of Service Engineers for Inspection of Boiler Pressure Parts, ducts & dampers and for Supervision of NDT services during Unit#7&8 Overhauling at MTPS Similar Category Operation and Maintenance Power House/Power Plant
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - 88 ACV SQN; CALIBRATION OF ANEMOMETER AND ROUTINE OF FBB; Service Provider