Online UPS Online UPS ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 3.0 KVA 3.0 KVA Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation ... isolation transformer , ... isolation transformer , ... isolation transformer Input ...
Online UPS Online UPS ( 5 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA * Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt ... isolation transformer , ... isolation transformer , ... isolation transformer Input ...
Supply of 800kVA, 11 kV-0.433kV 3ph Transformer as per specs at JHATIKARA, Supply of 800kVA, 11 kV-0.433kV 3ph Transformer as per specs at GURGAON, Supply of 1000kVA, 33 kV-0.433kV, 3ph LT Transformer as per specs at NEEMRANA, Supply of 1000kVA, 33 ... LT Transformer as ... LT Transformer as ... 3ph Transformer as ... 3ph Transformer as ... 3ph Transformer as ... 3ph Transformer as ...
PROVN OF FLAME PROOF FALSE CEILING AND FALSE CEILING DUCT COVERS WITH FIRE RETARTANT MATERIAL IN POWER ROOM 1 and2 AT 737 SU AND INSTALLATION OF ISOLATION TRANSFORMER AND ROHINI RADAR OF 301 TRU AT AF STN SURATGARH
Purchase of Hardware and Bus Bar material for 400KV (Assorted Type) as per requirement of specification (Nigam Design) required for augmentation work of 500 MVA transformer to be installed at 400 KV GSS Heerapura through Single Source Procurement
Shifting/Dismantling of HT/LT lines, Transformer, LT Pillar box etc. which are creating hurdles in the Road widening work and P and F of street light at Jharkhand Tiraha to 200 Feet Bypass Sirsi Road , JDA, Jaipur.
UPS 01 KVA back up 60 minite 1600 VAH,Input 160-260 volt, Out put volt single phase 50 HZ,1 GBT PWM with out in built isolation transformer,Make- Sukam,Microtek,Panasonic,Luminious,Uniline,Power one o
Contactor for 60 KVA Transformer Rated Current: 95 A, Rated Voltage: 690 V AC, main pole 4 Nos., Aux Contact (1NO + 1NC), Control Voltage: 230V AC (168 V AC-300 V AC means 230V AC +/- 30%) with surge
Supply of Bar Type LT Current Transformers of ratio 100/5 Amp. and 200/5 Amp.
supply of 10,16,25 kva 1-phase ALuminium wound Distribution Transformers Energy Efficient Level-2 with ICB
OK
Repair of damaged transformer plateform, VCB foundation, levelling gravelling of yard, construction of toe wall, yard fencing and other repair of building 33 KV S/S Badi Jodi, Rampura, Shahpura old, Khori, SaiwadPiplod under AEN (O and M) Shahpura.
CONSTRUCTION WORK OF C.C IN DEENANATH JI KI GALI IN FRONT OF GANESH TRADERS, SATYANARAYAN TRADING COMPANY CHOWK TO AGRAWAL FOOD AND GS TRANDING COMPANY TO GOVIND TRANDING COMPANY FROM TRANSFORMER CHOWK IN WARD NO.59 KISHANPOLE ZONE AREA
200VA 750V/24V AC, 1 PHASE CONTROL TRANSFORMER, DRY TYPE AND AIR COOLED FOR INDICATION. RDSO SPEC NO:-RDSO/PE/SPEC/AC/0203-2020 (REV-0). ACCEPTED MAKE: BHASIN PACKARD/ NACEI/ RAMYAA/ TROLEX/ ABROL/TRINITRON/ KONTACT CONSORTIUM/ ASK POWER.
Contactor for 60 KVA Transformer Rated Current: 95 A, Rated Voltage: 690 V AC, Main Pole: 4, Aux. Contact: 1NO + 1NC, Control Voltage: 230 V AC (168 V AC - 300 V AC) means 230 V AC +/ 30 % with surge
LOW VOLTAGE FUSE (WITHOUT HOLDER), TRANSFORMER (SEC.) GR.00 500V/25A, AS PER SR. 7, ITEM NO. 12F10 OF THE BILL OF MATERIAL OF RCF SPEC. NO. EDTS-355 (REV.1), USED FOR THE SECONDARY SIDE OF THE TRANSFO
Construction of Chain link Fencing work for 11/0.4 KV Transformers under Hanumangarh circle (Phase II) (JVV2324WSOB00058)
REPAIR AND TESTING OF DAMAGED SINGLE PHASE DISTRIBUTION TRANSFORMERS OF RATING FROM 5 KVA TO 25 KVA
Implementation of AMR system for Distribution Transformers and High Value Consumers on Infrastructure As A Service Basis
Winding Replacement & testing OF 220KV/33KV, 15 MVA transformer.
CONSTRUCTION OF DAMAR ROAD IN KHORI ROAD TRANSFORMER TO BHANDARI JI SHOP, BABULAL CHANDA SHOP TO SHYAM VATIKA RAJENDRA NAGAR AND VARIOUS OTHER NEARBY COLONIES IN WARD NO. 122 OF JAGATPURA ZONE (UNDER THE BUDGET ANNOUNCEMENT OF THE HONORABLE CHIEF MIN
WBM Road Construction Work From Mandi Road in Devnagar Colony to WBM Road ahead of Transformer to Master Mind School and from Master Mind School to Kamal Gurjar and Kamlesh Gurjar and Jitaram Meena to Gupteshwar Road ward no 16
Realignment work of 400KV,existing 220 kV, 132 kV Line, 400kV Incomer Bay, 220kV Phulera Bay and 220kV Bus Extension work for Installation of additional 01 No. of 400 220kV, 500 MVA Transformer at 400 kV GSS, Heerapura under Head Augmentation.
STEP DOWN TRANSFORMER CAPACITY 50KVA VOLTAGE INPUT 750 VOLTS OUTPUT 415 VOLTS AC, 50 HZ, CONFIRMING TO RDSO SPEC. NO. - EL/EOG/6/93 (REV-A)-97 , TYPE-1 SUITABLE FOR CONVENTIONAL TYPE EOG AC COACHES USED IN POW COACHES.
AUGMENTATION OF ELECTRICAL SUPPLY FOR INSTALLATION OF 01X100 KVA TRANSFORMER AND ALLIED WORKS AT CERTAIN AREA AND PROVN OF 3 PHASE ELECTRIC CONNECTION AT PROOF YARD FOR DEMIL PLANT IN CERTAIN AREA AT MIL STN JAISALMER UNDER GE (A) JAISALMER
Construction of 220/132kV, 1x160 MVA GSS at Reodar along with 132/33 KV , 20/25 MVA Transformer and associated Bay work at existing 132kV GSS Badgaon and Reodar including supply of all Equipments/Materials, Erection (including civil works) etc
Shifting / Dismantling of LT / HT lines / Pillars, Transformer and RMUs etc. which are creating hindrance during construction of 160 Feet Road and P and F of Street lights from CBI Phatak to 7 no. Bus Stand, Mahal Road, Jagatpura, Jaipur.
Online UPS Experience with Gov. Required 1 Year (s) Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 10.0 KVA 10.0kva Technology IGBT-PWM with inbuilt isolation transformer ... isolation transformer , ... isolation transformer , ... isolation transformer Input ...
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Office Space; Repair Maint of Transformer at MH area; Repair/Maint of transformer at MH area
LT Ring Type Current Transformer of ratio 200/5 A
Augmentation of 132 33 KV 20 25 MVA Transformer with Oil filteration and Strengthning of 132 KV and 33 KV Main Bus to twin Zebra and P and F of Yard Light at 132 KV GSS Hindoli as per RVPN BSR 2017
Construction of Transmission Elements 3 x 500 MVA, 400/220 kV Transformer along with associated 400 kV and 220 kV bays and 4 Nos. 400 kV line bay work at 400 kV substation Jaisalmer-2 including supply of all equipments/ materials, erection (inclu
REPAIRS AND MAINTENANCE TO HT OVERHEAD DISTRIBUTION SYSTEM, 11 KV LINE OF E/M SERVICES, HT VCBs/GO/DO OF 11 KV AND U/G CABLES, TRANSFORMER AND CONNECTED WORKS IN ARMY AREA AT UDAIPUR AND MOUNT ABU UNDER AGE(I) UDAIPUR
PROVN OF SOLAR SECURITY LIGHTS WITH POLES AT NFS NODE KHETOLAI AND PROVN OF UPGRADATION OF EXISTING (40 KVA) TRANSFORMER WITH 100 KVA AT NACHANA ASCON NODE AND PROVN OF POINT WIRING IN CERTAIN AREA AT MIL STN POKARAN UNDER AGE (I) POKARAN
5 KVA TRANSFORMER (TYPE - I) 415V / 415 V , 3 PHASE FOR SGAC COACHES WITH FILTER TO SPEC. NO. ICF/ELEC/906, REV. 1 OR LATEST. INPUT-415 V, 3 PHASE, 50 HZ. OUTPUT -415 V & 240 V, 3 PHASE WITH NEUTRAL, 50 HZ.
HT fuse link (Single bolted type) 20 Amp. 3.3/3.6 KVA transformer of LHB EOG non AC coaches as per M/s Cooper bussman CAT no. 3.6 WDOHS20 conf to RDSO spec. no RDSO/PE/Spec./TL/0158-2010 Rev-1, ( make
REPAIR / MAINT OF 33 KV POWER TRANSFORMERS, SWITCHGEAR AND SOLAR POWER PLANT AND CONNECTED ITEMS UNDER GE (A) SURATGARH
automatic line voltage corrector or step type auto transformer Automatic Line Voltage Corrector Or Step Type Auto Transformer ( 8 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Conforming to IS:8448 latest Yes - Rating in KVA 2.0 KVA 0.5 KVA, 1.0 KVA, 2.0 KVA, 3.0 KVA, 4.0 KVA, 5.0 KVA ISI Marked Yes Yes, No ISI Marked if Yes CM/L No. (If No write NA) NO - Type of winding Copper Copper, Aluminium Input Single Phase sine wave (160V-260V) Single Phase sine wave (160V-260V), single Phase Sine wave (120V-280v) Display Type of Meter Digital Volt Meter analog Volt Meter, Digital Volt Meter CONSTRUCTIONAL Mounting Type Floor mounting - Current rating of the Relay/contactors (Amp) Conforming to IS:8448 latest - Overall weight of ALVC (Kg) 5 KG - Provision of power Yes - 1/3 supply cord/terminal as applicable for input and output as per IS:8448 FUNCTIONAL Output Single Phase sine wave (210V-250V) - Overall efficiency of ALVC (%) >/= 95% - The product shall conform to the acceptance tests as per Cl. 12.1.1 of IS:8448 latest Yes - CERTIFICATIONS Availability of Type Test Report from Central Govt. NABL/ILAC Accredited lab to prove conformity to the Specification IS:8448 latest Yes - Type Test report No. VMS 001 - TTC report date 10/01/2018 - Name of Lab VMS LAB - Address of Lab SK ROAD CHENNAI - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Shimbhu Dayal Meena 326001, Government P G College Murti Choraha Jhalawar 8 15
automatic line voltage corrector or step type auto transformer Automatic Line Voltage Corrector Or Step Type Auto Transformer ( 3 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Conforming to IS:8448 latest Yes - Rating in KVA 5.0 KVA 0.5 KVA, 1.0 KVA, 2.0 KVA, 3.0 KVA, 4.0 KVA, 5.0 KVA ISI Marked No Yes, No ISI Marked if Yes CM/L No. (If No write NA) NA - Type of winding Copper Copper, Aluminium Input single Phase Sine wave (120V-280v) Single Phase sine wave (160V-260V), single Phase Sine wave (120V-280v) Display Type of Meter Digital Volt Meter analog Volt Meter, Digital Volt Meter CONSTRUCTIONAL Mounting Type Wall mounting - Current rating of the Relay/contactors (Amp) Conforming to IS:8448 latest - Overall weight of ALVC (Kg) 15 - Provision of power Yes - 1/3 supply cord/terminal as applicable for input and output as per IS:8448 FUNCTIONAL Output Single Phase sine wave (210V-250V) - Overall efficiency of ALVC (%) >/= 95% - The product shall conform to the acceptance tests as per Cl. 12.1.1 of IS:8448 latest Yes - CERTIFICATIONS Availability of Type Test Report from Central Govt. NABL/ILAC Accredited lab to prove conformity to the Specification IS:8448 latest Yes - Type Test report No. 84489815 - TTC report date 12.01.2011 - Name of Lab Blue Bird - Address of Lab B-71/3, Wazirpur Industrial Area, New Delhi- 110052 (india) - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Firoz Akhtar 327801, TIMEDA ROAD KUSHALGARH DIST- BANSWARA PIN CODE-327801 3 15
automatic line voltage corrector or step type auto transformer Automatic Line Voltage Corrector Or Step Type Auto Transformer ( 4 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Conforming to IS:8448 latest Yes - Rating in KVA 2.0 KVA 0.5 KVA, 1.0 KVA, 2.0 KVA, 3.0 KVA, 4.0 KVA, 5.0 KVA ISI Marked Yes Yes, No ISI Marked if Yes CM/L No. (If No write NA) NO - Type of winding Copper Copper, Aluminium Input Single Phase sine wave (160V-260V) Single Phase sine wave (160V-260V), single Phase Sine wave (120V-280v) Display Type of Meter Digital Volt Meter analog Volt Meter, Digital Volt Meter CONSTRUCTIONAL Mounting Type Floor mounting - Current rating of the Relay/contactors (Amp) Conforming to IS:8448 latest - Overall weight of ALVC (Kg) 5 KG - Provision of power Yes - 1/3 supply cord/terminal as applicable for input and output as per IS:8448 FUNCTIONAL Output Single Phase sine wave (210V-250V) - Overall efficiency of ALVC (%) >/= 95% - The product shall conform to the acceptance tests as per Cl. 12.1.1 of IS:8448 latest Yes - CERTIFICATIONS Availability of Type Test Report from Central Govt. NABL/ILAC Accredited lab to prove conformity to the Specification IS:8448 latest Yes - Type Test report No. VMS 001 - TTC report date 10/01/2018 - Name of Lab VMS LAB - Address of Lab SK ROAD CHENNAI - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Lal Chand Bohra 332713, Sita Ram Modi Govt. Sanskrit College Chaoni Neem-Ka-Thane Distt., Sikar, Rajasthan 4 15
automatic line voltage corrector or step type auto transformer Automatic Line Voltage Corrector Or Step Type Auto Transformer ( 7 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Conforming to IS:8448 latest Yes - Rating in KVA 2.0 KVA 0.5 KVA, 1.0 KVA, 2.0 KVA, 3.0 KVA, 4.0 KVA, 5.0 KVA ISI Marked Yes Yes, No ISI Marked if Yes CM/L No. (If No write NA) NO - Type of winding Copper Copper, Aluminium Input Single Phase sine wave (160V-260V) Single Phase sine wave (160V-260V), single Phase Sine wave (120V-280v) Display Type of Meter Digital Volt Meter analog Volt Meter, Digital Volt Meter CONSTRUCTIONAL Mounting Type Floor mounting - Current rating of the Relay/contactors (Amp) Conforming to IS:8448 latest - Overall weight of ALVC (Kg) 5 KG - Provision of power Yes - 1/3 supply cord/terminal as applicable for input and output as per IS:8448 FUNCTIONAL Output Single Phase sine wave (210V-250V) - Overall efficiency of ALVC (%) >/= 95% - The product shall conform to the acceptance tests as per Cl. 12.1.1 of IS:8448 latest Yes - CERTIFICATIONS Availability of Type Test Report from Central Govt. NABL/ILAC Accredited lab to prove conformity to the Specification IS:8448 latest Yes - Type Test report No. VMS 001 - TTC report date 10/01/2018 - Name of Lab VMS LAB - Address of Lab SK ROAD CHENNAI - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Shambhu Dayal Gupta 303103, Ganga Market Shahpura, Jaipur 7 15
Air Conditioner, automatic line voltage corrector or step type auto transformer
Air Conditioner, automatic line voltage corrector or step type auto transformer
Air Conditioner, automatic line voltage corrector or step type auto transformer
As per tender specfications
25 KV outdoor, Single phase oil filled t [25 KV outdoor, Single phase oil filled type Current Transformer with Terminal connectors of ratio 200-100/5 Amps as per RDSO Specification no. TI/SPC/PSI/CT/0210 (07/2021) with A & C slip No. 01.]
25 KV outdoor, Single phase oil filled t [25 KV outdoor, Single phase oil filled type Current Transformer with Terminal connectors of ratio 200-100/5 Amps as per RDSO Specification no. TI/SPC/PSI/CT/0210 (07/2021) with A & C slip No. 01.]
CA NO. CWE SGNR-70 OF 2019-20 SPECIAL REPAIRS TO LT PANEL AND CONVERSION OF LT OH LINE INTO UNDERGROUND LT CABLE AND PROVISION OF 100 KVA TRANSFORMER ALONGWITH HT CABLE, LT CABLE WITH AMF PANEL FOR ACCESS NODE AT MILITARY STATION SRI GANGANAGAR